Plan Review Stops For Permit 05040923 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-23 |
Time |
17:58 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-02-23 |
Time |
17:58 |
Sent To |
|
|
Notes |
2006-02-23 00:00:00 | OUTDOOR HOOD, BBQ AND FIREPLACE |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-08 |
Time |
12:56 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-09-08 |
Time |
12:56 |
Sent To |
PC |
|
Notes |
2005-09-08 00:00:00 | BUILDING REVIEW PROVISO: | | 1- AS AGREED WITH G.C. APPLY FOR SLIDING | | GLASS DOORS UNDER A SEPARATE PERMIT. | | 2- FIREPLACE: PROVIDE COMPLETE INFO. | | INCLUDING SPECIFIC MODEL AND COMBUSTION | | CALCULATIONS FOR MECHANICAL REVIEW. | | 3- PROVIDE COMPLETE AND SPECIFIC INFO. | | FOR BBQ HOOD AND GRILL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-08-02 |
Time |
11:20 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-08-02 |
Time |
11:20 |
Sent To |
PC |
|
Notes |
2005-08-02 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED TO PASS ZONING FIRST. IF HOUSE | | NEEDS TO BE LOCATED ON THE ZERO LOT LINE | | THEN OPENINGS ARE NOT ALLOWED BY TABLE | | 600 FBC 2001. | | | | 2- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | 3- PROVIDE COMPLETE SPECS FOR APPROVED | | BBQ AND EXTERIOR HOOD. SEC. 2808 FBC | | 2001. SEE PLANS FOR ARCHITECT'S SPECS. | | | | 4- STILL IS NOT CLEAR IF USING SHUTTERS | | OR IMPACT GLAZING. LETTER SUBMITTED | | STATES THAT SHUTTERS UNDER A SEPARATE | | PERMIT. WHILE, ARCHITECT'S PLANS STATES | | THAT IMPACT GLASS TO BE USED IN DOORS | | AND WINDOWS. IN ADDITION, SOME OF THE | | PRODUCT APPROVALS SUBMITTED ARE WITH | | IMPACT GLAZING AND OTHERS ARE NOT. | | PROVIDE COMPLETE CONSTANT INFORMATION | | FOR EITHER WAY TO EXPEDITE AND | | FACILITATE THE REVIEW. | | | | 5- IF IMPACT GLASS IS NOT USED, THEN | | PLANS NEED TO SPECIFY SAFETY GLASS IN | | HIS BATH, HER BATH, GUEST BATH AND BATH | | #3. SEC. 2405.2. FBC 2001. | | | | 6- ANCHOR SCHEDULE: CLARIFY WHY | | CONNECTORS G AND H HAVE THE SAME UPLIFT | | CAPACITY IF THEY HAVE DIFFERNT NUMBER OF | | NAILS. SEE CATALOGUE FOR NUMBER OF NAILS | | TO BE USED TO OBTAIN TESTED UPLIFT | | CAPACITY. PROVIDE TESTING RESULTS AND | | ENGINEERED CALCS FOR NAIL NUMBER THAT | | DIFFER FROM THOSE TESTED AND PUBLISHED | | BY THE MANUFACTURER. SEC. 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. | | | | 7- MULLION SIZE SPECIFIED FOR FIXED | | WINDOWS IN LIVING ROOM AREA DOESN'T | | RESIST THE DESIGN PRESSURES. SEE PRODUCT | | APPROVAL. SPECIFY BIGGER MULLION AND | | ANCHORS. SEC. 104.2.1.2 CITY AMENDMENTS. | | | | 8- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR: | | A) MULLION SPECIFIED BY ARCHITECTON | | ITEM #7 ABOVE. | | B) CASEMENT WINDOWS THAT MATCH FLORIDA | | PRODUCT APPROVAL AND WINDOWS SHOWN ON | | PLANS. | | C) ALL WINDOWS AND DOORS TO BE USED. | | IMPACT OR NON IMPACT. | | | | 9- PROVIDE COMPLETE SPECS AND LISTING | | FOR FIREPLACE SHOWING COMPLIANCE WITH | | 2806 FBC 2001. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-06-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-06-02 |
Time |
10:27 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-06-02 |
Time |
10:27 |
Sent To |
PC |
|
Notes |
2005-06-02 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | 1- SEE COMMENTS BY ZONING. IF HOUSE | | NEEDS TO BE LOCATED ON THE ZERO LOT | | LINE, THEN, OPENINGS ARE NOT ALLOWED BY | | TABLE 600 FBC 2001. | | | | 2- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | 3- SHEET T1: A) UPDATE GENERAL NOTES. | | SEE COMMENTS ON PLANS. SEE RESPECTIVE | | FBC CHAPTER FOR PROPER REFERENCE (EG: | | CHAPTER 19 ACI 318) AND CHAPTER 35 FOR | | PROPER REFERENCE EDITION. | | | | B) DESIGN PARAMETERS: CLARIFY WHERE IS | | THE BASIC VELOCITY PRESSURE TAKEN FROM. | | SEE SECTION 1606 FBC 2001. | | ALSO, CLARIFY WHY THE MIN. SOIL BEARING | | PRESSURE IS - NA?. | | | | 4- PROVIDE COMPLETE SPECS FOR BBQ | | SHOWING THAT IT WAS DESIGNED TO BE | | INSTALLED IN THE PORCH. SEC. 2808 FBC | | 2001. | | | | 5- PROVIDE COMPLETE INFORMATION FOR | | STORM SHUTTERS OR APPLY FOR A SEPARATE | | PERMIT. | | | | 6- SHEET A1: A) SPECIFY COLUMNS AT BAY | | WINDOW IN MASTER BEDROOM. | | | | B) WHAT DOES TS-2 SPECIFIED ON CONCRETE | | PAD BETWEEN GARAGE AND BEDROOM #2 STANDS | | FOR?. SEC. 104.2.1.2 CITY AMENDMENTS TO | | FBC 2001. | | | | C) DETAIL 5 FOR FOOTING BETWEEN GARAGE | | AND CLUB ROOM DOESN'T MATCH. REVISE AS | | REQUIRED. | | | | 7- SHEET A2; A) NOTE #1 AND #6 CALL FOR | | IMPACT GLAZING ON DOORS AND WINDOWS. | | NOTE ON DESIGN PRESSURES CHART SHOWN ON | | ELEVATIONS CALLS FOR STORM SHUTTERS. | | CLARIFY/REVISE AS REQUIRED. | | | | B) REVISE SIZES FOR FIXED WINDOWS AT | | LIVING ROOM (36' X 234" FG ?). | | | | C) SPECIFY SAFETY GLASS AT HIS BATH, HER | | BATH, GUEST SUITE BATH, BATH #3 AND | | LIVING ROOM. SEE PLANS AND SECTION | | 2405.2 FBC 2001. | | | | 8- SHEET A3: A) REVISE/UPDATE TRUSS | | ANCHOR SCHEDULE. SEE LATEST CATALOGUE | | (2005) WHICH WAS REVISED TO COMPLY WITH | | SEC. 1609.4.3 FBC 2001. OR, PROVIDE | | COMPLETE ENGINEERING CALCS THAT COMPLY | | WITH SEC. 1609.4.3 FBC 2001 FOR TYPE AND | | NUMBER OF CONNECTORS THAT DIFFER FROM | | THOSE TESTED AND PUBLISHED BY THE | | MANUFACTURER. SEC. 104.2.1.2OF CITY | | AMENDMENTS TO FBC 2001. | | | | B) CONNECTOR THD210 IS A WOOD TO WOOD | | CONNECTOR. NEED MASONRY CONNECTOR. SEE | | CATALOGUE FOR PROPER MASONRY CONNECTOR. | | | | C) DETAIL E/13 DOESN'T APPLY. THERE IS | | NOT CONCRETE WALL TO BE ATTACHED TO. | | REVISE AS REQUIRED. SEE PLANS. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | D) SPECIFY CONNECTOR FOR TRUSS GIRDER | | RESTING ON WOOD COLUMN LOCATED IN | | VESTIBULE FOR CLUB ROOM AND MASTER | | BEDROOM. SEC. 104.2.1.2 CITY AMENDMENTS. | | | | 9- PROVIDE FLORIDA OR APPLY FOR LOCAL | | PRODUCT APPROVAL FOR CORNER SLIDING | | GLASS DOORS. | | | | 10- WINDOW AND DOOR MULLIONS: CLEARLY | | SPECIFY MULLION SIZE AND ANCHOR TYPE TO | | BE USED ACCORDING TO THE ASSEMBLY TO BE | | INSTALLED ON TO VERIFY COMPLIANCE WITH | | THE DESIGN PRESSURES. SEC. 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. | | | | 11- DADE COUNTY NOA SUBMITTED FOR | | CASEMENT WINDOWS DOESN'T MATCH NOA | | LISTED ON FLORIDA PRODUCT APPROVAL COVER | | PAGE. REVISE AS REQUIRED. | | | | 12- PROVIDE COMPLETE SPECS AND LISTING | | FOR FIREPLACE SHOWING COMPLIANCE WITH UL | | 127 REQUIREMENTS. SEC. 2806 FBC 2001. | | | | ***PLEASE DON'T STAPLE PRODUCT APPROVALS | | TO PLANS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-11 |
Time |
18:25 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-10-11 |
Time |
17:53 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2006-09-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-28 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-28 |
Time |
14:33 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-04-17 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-04-17 |
Time |
11:15 |
Sent To |
PC |
|
Notes |
2006-04-17 00:00:00 | REDLINED 110.26 FOR A/C DISC'C. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
19:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-23 |
Time |
19:20 |
Sent To |
PC |
|
Notes |
2006-03-23 00:00:00 | REDLINED: | | 424.3B MIN OCPF OR AHU'S (AHU #1) TO BE | | 125%. PLEASE SEE 20A BRKR SHOWN FOR 10KW | | UNIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-09-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-07 |
Time |
19:45 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-09-07 |
Time |
19:45 |
Sent To |
B |
|
Notes |
2005-09-07 00:00:00 | REDLINED 110.26 FOR DISCONNECTS. | | | | REDLINED 210.52C1 FOR KITCHEN | | COUNTERSPACE RECEPTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-07-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-07-19 |
Time |
07:24 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-07-19 |
Time |
07:16 |
Sent To |
P |
|
Notes |
2005-07-19 00:00:00 | ********** UNSAT ********* | | | | 1)NOTE: PLEASE SEE ZONING COMMENTS, THIS | | DIRECTLY AFFECTS ELECTRICAL PLANS AND | | LAYOUT OF HOUSE IN MORE THAN ONE WAY. | | PLEASE ADJUST HOWEVER NESSCESARY TO MEET | | ZONING COMMENTS. | | | | | | 2)NOTE: PLEASE SEE REDLINED 210.52C1,FOR | | KITCHEN COUNTERSPACE. | | PLEASE SEE 110.26 FOR A/C CU DISC'S. | | | | PLEASE NOTICE BOTH OF THESE ITEMS ARE | | REDLINED ITEMS AND DO NOT NEED TO BE | | CORRECTED ON PLANS UNLESS REV'S ARE MADE | | TO ELECTRICAL PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-04-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-28 |
Time |
10:34 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-04-28 |
Time |
10:34 |
Sent To |
M |
|
Notes |
2005-04-28 00:00:00 | ******** UNSAT ********** | | | | 1)NOTE: PLEASE SEE ZONING COMMENTS WHICH | | WILL HAVE A DIRECT AFFECT ELECTRICAL | | PLANS AND CHANGES WHICH MAY NEED TO BE | | MADE. | | | | 2)NOTE: PLEASE SEE "PANEL C" IS NOT | | SHOWN ON PLANS. | | PLEASE SHOW AT THIS TIME , SINCE PLANS | | ARE COMING BACK FOR ZONING COMMENTS. | | | | 3)NOTE: PLEASE SEE ONE COPY OF | | ELECTRICAL PLANS WERE STAMPED IN ERROR | | DUE TO UNKNOWN ZONING COMMENTS. | | THE ONE STAMPED SET HAS NOW BEEN VOIDED | | AND WILL NEED TO BE REPLACED. | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-23 |
Time |
19:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-23 |
Time |
19:38 |
Sent To |
E |
|
Notes |
2006-09-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-14 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-14 |
Time |
16:35 |
Sent To |
E |
|
Notes |
2006-04-14 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-21 |
Time |
18:00 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-21 |
Time |
18:00 |
Sent To |
E |
|
Notes |
2006-03-21 00:00:00 | DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-02-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-14 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-14 |
Time |
08:50 |
Sent To |
B |
|
Notes |
2006-02-14 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-08-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-24 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-24 |
Time |
11:25 |
Sent To |
Z |
|
Notes |
2005-08-24 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-07-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-18 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-18 |
Time |
09:59 |
Sent To |
E |
|
Notes |
2005-07-18 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-07-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-11 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-11 |
Time |
11:14 |
Sent To |
Z |
|
Notes |
2005-07-11 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-04-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-27 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-27 |
Time |
16:03 |
Sent To |
E |
|
Notes |
2005-04-27 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-06-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-06-02 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-04-15 |
Time |
14:32 |
Sent To |
PC |
|
Notes |
2005-04-15 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2005-09-06 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-09-06 |
Time |
11:43 |
Rev Time |
1.00 |
Received By |
prafter |
Date |
2005-09-06 |
Time |
11:43 |
Sent To |
B |
|
Notes |
2005-09-06 00:00:00 | MECH. PLAN REVIEW: | | | | FIRE PLACE INFORMATION NOT MARKED, | | GERNARIC MODELS. BUILDING PLAN REVIEW TO | | CLEARFIE WITH G/C CONT. | | | | PAT RAFTER 561/805/6728 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-07-27 |
Time |
07:07 |
Rev Time |
0.50 |
Received By |
prafter |
Date |
2005-07-27 |
Time |
07:07 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-05-03 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-05-03 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
prafter |
Date |
2005-09-06 |
Time |
11:43 |
Sent To |
P |
|
Notes |
2005-05-03 00:00:00 | MECH. PLAN REVIEW: | | | | 1. R/A DUCT NOT SIZED, AHU 1. | | | | 2. SUPPLY AIR FROM AHU 1. REFLECT 12" | | FOR TWO TRIANGELS THEN INCRESES TO 14" . | | PLEASE CORRECT AND RESUMMIT. | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | PATTY KRAUSS. | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2005-09-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-02 |
Time |
07:52 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-09-02 |
Time |
07:52 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2005-07-23 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-07-23 |
Time |
14:23 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-07-23 |
Time |
14:23 |
Sent To |
M |
|
Notes |
2005-07-23 00:00:00 | DENIED; | | 1. SECOND REQUEST, ADD MORNING SINK TO | | RISER DIAGRAM. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-05-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-05-03 |
Time |
16:52 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-05-03 |
Time |
16:52 |
Sent To |
B |
|
Notes |
2005-05-03 00:00:00 | DAY SINK MISSING FROM RISER DIAGRAM. | | ZONING COMMENTS WILL CHANGE FLOOR PLAN. | | PLUMBING PLANREVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2005-09-01 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-01 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-01 |
Time |
13:48 |
Sent To |
B |
|
Notes |
2005-09-01 00:00:00 | GIVEN TO LUIS MARTINEZ. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2005-07-15 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-15 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-07-15 |
Time |
13:01 |
Sent To |
I |
|
Notes |
2005-07-15 00:00:00 | DENIED, | | 1. MUST HAVE INTERIOR ACCESS TO THE | | GUEST SUITE FROM MAIN STRUCTURE. | | 2. SITEPLAN DOES NOT MATCH WHAT WAS | | APPROVED FOR SETBACK, "LOT 13 WILL | | ADHERE TO THE MODIFIED ZERO SETBACKS | | WITH THE ZERO SIDE OF THE HOUSE LOCATED | | ON THE 3'1' ZERO LINE. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-04-26 |
Time |
18:04 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-04-25 |
Time |
18:48 |
Sent To |
I |
|
Notes |
2005-04-26 00:00:00 | DENIED, | | 1. MUST HAVE INTERIOR ACCESS TO THE | | GUEST SUITE FROM MAIN STRUCTURE. | | 2. MUST REMOVE U/C REF & SINK FROM | | GUEST SUITE. | | 3. MUST PROVIDE SITEPLAN THAT MATCHES | | THE PLAT THAT WAS APPROVED (APPROVED | | 2002, ZERO LOT) | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 | 2005-04-25 00:00:00 | HAVE QUESTIONS TO GRACE REGARDING PLANS |
|
|