Plan Review Stops For Permit 05040914 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-07 |
Time |
17:49 |
Rev Time |
0.40 |
Received By |
jgomez |
Date |
2006-02-07 |
Time |
17:49 |
Sent To |
PC |
|
Notes |
2006-02-07 00:00:00 | ENERGY CALCULATIONS AND BUILDING | | REVISIONS AND PRODUCT APPROVALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-12-07 |
Time |
12:27 |
Rev Time |
0.75 |
Received By |
jgomez |
Date |
2005-12-07 |
Time |
12:27 |
Sent To |
PC |
|
Notes |
2005-12-07 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- ENERGY CALCULATIONS SUBMITTED ARE FBC | | 2004 FORM. NEED FBC 2001 FORMS SINCE | | PLANS WERE REVIEWED UNDER THE FBC 2001. | | | | 2- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL AS REQUIRED BY RULE 9B-72 OF | | DEPARMENT OF COMMUNITY AFFAIRS (DCA) | | FOR: | | A) ATRIUM DOOR. SEE PLANS FOR DOOR SIZE | | AND SWING DIRECTION. | | | | B) FRENCH DOORS AT GREAT ROOM. SEE PLANS | | FOR SIZE SPECIFIED. | | | | 3- SHEET A-5 WAS NOT SUBMITTED WITH THIS | | PACKAGE. NEED TO SUBMIT IR TO SEE ROOF | | PLAN REVISIONS. | | | | 4- OWES $60.00 FOR THIS SUBMITTAL | | REVISION FEES. ($50.00 FLAT FEE PLUS ONE | | DRAWINGS). | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-08-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-08-31 |
Time |
13:08 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-08-31 |
Time |
12:08 |
Sent To |
PC |
|
Notes |
2005-08-31 00:00:00 | SUBMITTAL BUILDING REVIEW CHECKLIST: | | 1- SEPARATE PERMIT FOR SHUTTERS HAS NOT | | BEEN APPLIED FOR YET. | | | | 2- ROOF FRAMING PLAN: CONNECTORS NEED TO | | BE REVISED AT ENTRY FOYER AREA. TRUSSES | | ARE RESTING ON A GIRDER TRUSS, NOT ON A | | CONCRETE BEAM. REVISE AS REQUIRED. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | 3- TRUSS ANCHOR SCHEDULE: REVISE NUMBER | | OF NAILS SPECIFIED FOR CONNECTOR HUS26. | | SEE 2005 CATALOGUE. | | | | 4- ONE HOUR FIRE RATED DOOR AT ATRIUM | | PRODUCT APPROVAL SUBMITTED IS FOR | | OUTSWING DOOR. PLANS SHOW INSWING DOOR. | | REVISE AS REQUIRED. | | ***NOTE: DOOR AT THIS LOCATION NEED NOT | | TO BE FIRE RATED. WALL IS NOT LOCATED IN | | THE ZERO LOT LINE. BESIDES, THIS WALL IS | | MORE LIKE A FENCE NOT A BUILDING WALL. | | THEREFORE, TABLE 600 FBC 2001 DOESN'T | | APPLY. | | | | 5- WINDOW MULLION SIZE SPECIFIED FOR | | FIXED WINDOWS AT GREAT ROOM DOESN'T | | RESIST THE CALCULATED DESIGN PRESSURES. | | SEE PRODUCT APPROVAL AND REVISE SIZE AS | | REQUIRED. SEC. 104.2.1.2 CITY AMENDMENTS | | TO FBC 2001. | | | | 6- ALL REVISED DRAWINGS WILL BE SUBJECT | | TO THE REVISION FEES. SEE THE SUBMITTAL | | FORM FOR APPLICABLE FEES. | | | | 7- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR FRENCH DOORS. SEE PLANS FOR | | REQUIRED SIZE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-06-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-06-28 |
Time |
17:41 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-06-28 |
Time |
17:40 |
Sent To |
PC |
|
Notes |
2005-06-28 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- CONTRACTOR AGREED TO APPLY FOR STORM | | SHUTTERS UNDER A SEPARATE PERMIT. | | 2- SUBMIT SOIL TEST REPORT WITH FOOTING | | SIZE REVISION. | | 3- ROOF FRAMING PLAN: REVISE CONNECTOR | | SPECIFIED AT FRONT PORCH MASONRY BEAM. | | NEED MASONRY CONNECTOR. SEE DETAIL 5/D1. | | **NOTE: ROOF FRAMING PLAN CALLS FOR | | DETAIL 6/D1. REVISE FOR 5/D1. | | 4- TRUSS ANCHOR SCHEDULE: REVISE SIZE OF | | NAIL USED FOR HUS26. SEE CATALOGUE. | | 5- PROVIDE PRODUCT APPROVAL FOR: | | A) 1 HR FIRE RATED ASSEMBLY EGRESS OP'G. | | | | B) FRENCH DOORS AS SHOWN ON PLANS. | | C) 8'-0" HIGH ENTRY DOORS. | | 6- PROVIDE CLEAR WINDOW AND DOOR | | SCHEDULES WITH MATCHING SYMBOLS. | | 7- PROVIDERECORDED EGRESS EASEMENT. | | 8- REVISE SIZE OF WINDOW SPECIFIED ON | | WINDOW SCHEDULE FOR BEDROOM #3. SEE PLAN |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-05-20 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-06-28 |
Time |
17:40 |
Sent To |
PC |
|
Notes |
2005-05-20 00:00:00 | CHECKLIST: | | | | 1- MEETING WITH RON ELLISH. HE REQUESTED | | TO LOG OUT PLANS TO MAKE CORRECTIONS | | BASED ON COMMENTS PREVIOUSLY DONE TO | | SAME MODEL. |
|
|
Review Stop |
B1 |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2005-06-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-06-28 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-06-28 |
Time |
17:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-01-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-17 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-17 |
Time |
10:56 |
Sent To |
PC |
|
Notes |
2006-01-17 00:00:00 | REDLINED 210.11C3, SHOWS A-38 AS BLANK | | YET THIS IS SHOWN ON PLANS AS BATHRM. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-13 |
Time |
16:37 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-06-13 |
Time |
16:31 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-25 |
Time |
13:07 |
Rev Time |
0.40 |
Received By |
dpalmer |
Date |
2005-04-25 |
Time |
13:07 |
Sent To |
M |
|
Notes |
2005-04-25 00:00:00 | ********** UNSAT ************* | | | | 1)NOTE: PLEASE SEE PANEL "A" SHOWS FEED | | TO PANEL "B" AS 100A OCP ON #6 AWG. | | PLEASE SEE 240.4,310.16 AND PLEASE | | CORRELATE WITH RISER DIAGRAM. | | PLEASE ALSO SEE THIS IS SHOWN AS 100A SP | | BRKR ON ONE PHASE? (MISPRINT) | | | | 2)NOTE: PLEASE SEE PANEL "B" SHOWS SUB | | PANEL "C" IN TWO DIFFERENT LOCATIONS? | | PLEASE SEE THIS IS SHOWN ON SAME PHASE. | | PLEASE ALSO CORRELATE AWG FOR 60A OCP. | | SHOWS #6 AND #8? | | PLEASE ALSO SEE SINGLE POLE 60A FOR | | ADDITIONAL SUB PANEL. | | PLEASE SEE 240.4,310.16, 310.15B6 | | | | 3)NOTE: PLEASE SEE NOTE ADDED TO CENTER | | OF PLANS WHICH IS A PROVISO SET UP BY A | | PLAN REVIEWER FOR A PREVIOUS PROJECT. | | THIS COMMENT FROM OTHER ELECTRICAL PLAN | | REVIEW SHOULD NOT BE LOCATED ON THESE | | PLANS. | | PLEASE REMOVE. | | | | 4)NOTE: PLEASE SEE SD'S ARE REQUIRED TO | | BE WIRED "INLINE" ON THE SAME CIRCUIT, | | HOWEVER PLANS INDICATE TWO SEPARATE | | CIRCUITS FOR THE SD'S.THESE MAY NOT BE | | ON THE SAME CIRCUIT. | | NFPA-72 8-1.4.1.6.2 | | | | 5)NOTE: PLEASE SEE ONE OF THE ABOVE | | CIRCUITS FOR SD'S (#38) IS THE SAME | | CIRCUIT ON PANEL SCHEDULE FOR SUB PANEL | | "B". | | | | 6)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | ON PLANS. | | 215.5 | | | | 7)NOTE: PLEASE SHOW LOADS ON EACH | | ELECTRICAL PANEL. PANEL "B AND "C | | MENTIONS TO SEE LOAD CALCS, HOWEVER | | THESE PANELS NEED TO SHOW ACTUAL LOAD | | FOR THOSE PANELS. | | 220,215.5 | | | | 8 )NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | 9)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | TUB IS SHOWN ON ON PANEL SCHEDULE, | | HOWEVER THIS IS NOT SHOWN ON PLANS AT | | WHAT APPEARS TO BE THE WP/JACUZZI TUB. | | | | 10)NOTE: PLEASE SEE MISSING GFI RECEPT | | ON KITCHEN COUNTERSPACE. | | 210.52C1,210.8A6 | | | | PLEASE BE SURE TO REMOVE ALL OLD VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. | | PLEASE SEE ONE COPY/SET OF OLD SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-06 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-06 |
Time |
09:40 |
Sent To |
B |
|
Notes |
2006-02-06 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-01-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-06 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-06 |
Time |
09:50 |
Sent To |
E |
|
Notes |
2006-01-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-19 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-19 |
Time |
08:55 |
Sent To |
B |
|
Notes |
2005-10-19 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-07-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-29 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-29 |
Time |
16:21 |
Sent To |
B |
|
Notes |
2005-07-29 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-07-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-29 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-29 |
Time |
15:55 |
Sent To |
B |
|
Notes |
2005-07-29 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-08 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-08 |
Time |
08:19 |
Sent To |
E |
|
Notes |
2005-06-08 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-04-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-22 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-22 |
Time |
11:10 |
Sent To |
E |
|
Notes |
2005-04-22 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-05-20 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-04-15 |
Time |
14:02 |
Sent To |
PC |
|
Notes |
2005-04-15 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-06-21 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-06-21 |
Time |
17:17 |
Sent To |
B |
|
Notes |
2005-06-21 00:00:00 | PASS PRIVISO | | PLEASE SIZE DUCT THAT IS MARKED ON THE | | PLAN BEFOR ROUGH INSPECTION. | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-04-26 |
Time |
10:53 |
Rev Time |
0.50 |
Received By |
prafter |
Date |
2005-04-26 |
Time |
10:53 |
Sent To |
P |
|
Notes |
2005-04-26 00:00:00 | MECH. PLAN REVIEW. | | SUPPLY AIR DUCT NOT SIZED TO GUEST | | SUITE. | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | PATTY KRAUSS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-20 |
Time |
14:25 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2005-06-20 |
Time |
14:25 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-05-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-05-03 |
Time |
16:03 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-05-03 |
Time |
16:03 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-04-21 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-04-21 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-04-21 |
Time |
15:51 |
Sent To |
I |
|
Notes |
|
|