Plan Review Stops For Permit 05040909 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2006-01-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-01-26 |
Time |
18:27 |
Rev Time |
0.40 |
Received By |
jgomez |
Date |
2006-01-26 |
Time |
18:27 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2006-01-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-01-04 |
Time |
18:31 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-01-04 |
Time |
18:31 |
Sent To |
PC |
|
Notes |
2006-01-04 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | 1- ENERGY CALCULATIONS SUBMITTED DON'T | | MATCH ORIENTATION OF HOUSE. SEE SURVEY | | FOR CORRECT HOUSE ORIENTATION. ENERGY | | CALCULATIONS NEED TO BE CALCULATED FOR | | WORST CASE SCENARIO OR THEY MUST MATCH | | ORIENTATION OF THE HOUSE ON THE SPECIFIC | | LOT. ENERGY CALCULATIONS SUBMITTED DON'T | | COMPLY WITH EITHER REQUIREMENT. | | | | 2- OWES $70.00 FOR REVISION FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-11-17 |
Time |
10:43 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2005-11-17 |
Time |
10:43 |
Sent To |
PC |
|
Notes |
2005-11-17 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | 1- A) ENERGY CALCULATIONS WERE REVISED. | | NEED TO USE FBC 2001 FORM NOT FBC 2004 | | FORM. PROVIDE CORRECT ENERGY CALCS FORM. | | B) ENERGY CALCULATIONS NEED TO BE | | CALCULATED FOR WORST CASE SCENARIO OR | | SITE SPECIFIC ORIENTATION. CALCULATIONS | | SUBMITTED ARE NOT FOR SITE SPECIFIC | | ORIENTATION FOR THIS HOUSE. IT DOESN'T | | MATCH HOUSE ORIENTATION. SEE SURVEY AND | | PROVIDE CORRECT SITE SPECIFIC | | ORIENTATION. | | | | 2- A) REVISE ROOF FRAMING PLAN AT ENTRY | | AREA. PROVIDE CORRECT FRAMING PLAN AND | | CORRESPONDING CONNECTOR. THIS DWG WAS | | NOT SUBMITTED WITH THIS SUBMITTAL. | | B) REVISE TRUSS ANCHOR SCHEDULE. | | SPECIFY CORRECT SIZE AND NUMBER OF NAILS | | FOR CONNECTOR HUS26. DWG NOT SUBMITTED. | | | | 3- PROVIDE CORRECT INFORMATION FOR FIRE | | RATED DOOR AT ATRIUM: | | A) DRAWINGS ARE FOR "OUTSWING" DOOR, | | WHILE DADE COUNTY NOA IS FOR "INSWING" | | DOOR. PROVIDE MATCHING INFORMATION. | | B) NEED 8'-0" HIGH DOOR AS SPECIFIED | | ON ARCHITECT'S PLANS. | | | | 4- REVISED DRAWINGS AND ENERGY | | CALCULATIONS WILL BE SUBJECT TO REVISION | | FEES AS APPLICABLE. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-08-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-08-31 |
Time |
13:54 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-08-31 |
Time |
13:54 |
Sent To |
PC |
|
Notes |
2005-08-31 00:00:00 | SUBMITTAL BUILDING REVIEW CHECKLIST; | | 1- SEPARATE PERMIT FOR SHUTTERS HAS NOT | | BEEN APPLIED FOR YET. | | | | 2- ENERGY CALCULATIONS WERE REVISED. NOW | | CEILING FAN CREDIT WAS TAKEN. THEREFORE, | | NEED TO REVISE ELECTRICAL PLAN SHOWING | | SIZE OF CEILING FANS, INCLUDING FANS IN | | THE GREAT ROOM AS REQUIRED BY TABLE 6-6 | | OF CHAPTER 13 FBC 2001. | | | | 3- ROOF FRAMING PLAN NEEDS TO BE REVISE | | AT ENTRY PORCH AREA TO MATCH FOUNDATION | | PLAN AND FLOOR PLAN. NOTICE THAT | | CONCRETE BEAM DOESN'T EXTEND ALL THE WAY | | INSIDE TO THE FOYER AREA. CONCRETE BEAM | | IS ONLY AT ENTRY PORCH AREA. REVISE AS | | REQUIRED, INCLUDING TRUSS CONNECTORS AS | | REQUIRED. SEC. 104.2.1.2 CITY AMENDMENTS | | TO FBC 2001. | | | | 4- TRUSS ANCHOR SCHEDULE: REVISE NUMBER | | OF NAILS SPECIFIED FOR CONNECTOR HUS26. | | SEE 2005 CATALOGUE. | | | | 5- ONE HOUR FIRE RATED DOOR AT ATRIUM | | PRODUCT APPROVAL SUBMITTED IS FOR | | OUTSWING DOOR. PROVIDE INSWING DOOR AS | | SHOWN ON PLANS OR REVISE PLANS AS REQ'D. | | ***NOTE; DOOR NEED NOT TO BE FIRE RATED. | | WALL IS CONSIDERED LIKE A FENCE NOT A | | BUILDING WALL. THEREFORE, TABLE 600 FBC | | 2001 DOESN'T APPLY. REVISE PLANS IF | | SPECIFICATIONS CHANGE. | | | | 6- WINDOW MULLION SIZE SPECIFIED FOR | | FIXED WINDOWS AT GREAT ROOM DOESN'T | | RESIST THE CALCULATED DESIGN PRESSURES. | | SEE PRODUCT APPROVAL AND REVISE SIZE OF | | MULLION AS REQUIRED. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | | | 7- ALL REVISED DRAWINGS WILL BE SUBJECT | | TO THE REVISION FEES. SEE SUBMITTAL FORM | | FOR APPLICABLE FEES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-06-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-06-10 |
Time |
18:04 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2005-06-10 |
Time |
18:04 |
Sent To |
E |
|
Notes |
2005-06-10 00:00:00 | BUILDING REVIEW PROVISO: | | 1- SHUTTERS UNDER A SEPARATE PERMIT. | | 2- REVISE ENERGY CALCULATIONS. NEED THEM | | TO BE CALCULATED FOR WORST CASE SCENARIO | | 3- REVISE FRONT ELEVATION TO SHOW ENTRY | | DOORS AS SHOWN ON PRODUCT APPROVAL. | | 4- ROOF FRAMING PLAN: REVISE CONNECTOR | | SPECIFIED AT ENTRY PORCH. NEED MASONRY | | CONNECTOR. SEE DETAIL 5/D-1. | | 5- TRUSS ANCHOR SCHEDULE: REVISE TYPE OF | | NAIL USED FOR HUS26. SEE CATALOGUE. | | 6- PROVIDE PRODUCT APPROVAL FOR: A) ONE | | HR FIRE RATED ASSEMBLY AT EGRESS OPENING | | B) 12'-0" WIDE SLIDING GLASS DOORS. | | C) 8'-0" HIGH ENTRY DOORS. | | 7- PROVIDE CLEAR WINDOW AND DOOR | | SCHEDULES. NEED MATCHING SYMBOLS. | | 8- PROVIDE COPY OF EGRESS EASEMENT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-05-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-05-10 |
Time |
17:49 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-05-10 |
Time |
17:49 |
Sent To |
PC |
|
Notes |
2005-05-10 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | 2- SOIL TEST REPORT RECOMMENDS 18" MIN. | | FOOTING WIDTH. FOUNDATION PLAN CALLS FOR | | 16" WIDTH. REVISE AS REQUIRED. | | | | 3- 45 DEGREE WINDOW ON BEDROOM #3 AT | | ZERO LOT LINE WALL IS NOT ALLOWED BY | | TABLE 600 FBC 2001. NO OPENINGS ALLOWED. | | | | 4- PROVIDE NOTE ON DEN ROOM STATING THAT | | ROOM IS NOT ALLOWED TO BE USED FOR | | SLEEPING PURPOSES. OR, PROVIDE COMPLETE | | EGRESS REQUIREMENTS INCLUDING RECORDED | | EGRESS EASEMENT. | | | | 5- PROVIDE DETAIL/SPECS FOR CEILING | | INSTALLATION AT ENTRY AND REAR PORCHES. | | SPECIFY FASTENERS TYPE AND SPACING . SEE | | SEC. 2504.2 FBC 2001. | | | | 6- SPECIFY SUPPORTS AND SPACING FOR WWM | | IN CONCRETE SLAB. SEE EXCEPTION IN SEC. | | 1909.3 FBC 2001. | | | | 7- SPECIFY FOOTINGS FOR ENTRY COLUMNS. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | 8- SHEET A-5.0:A) ROOF NAILING ZONE | | DIAPHRAGM IS MISSING ZONE 3. SEE FIGURE | | 1606.2(C) FBC 2001. | | | | B) DETAIL 3 SPECIFIES HGUS 28-2 SIMPSON | | CONNECTOR IS A WOOD TO WOOD CONNECTOR. | | NEED TO SPECIFY CIFY WOOD TO MASONRY | | CONNECTOR. REVISE AS REQUIRED. | | | | C) DETAILS 1 AND 2: REVISE TYPE OF | | NAILS. SEE SIMPSON CATALOGUE. | | | | D) REVISE CONNECTOR SPECIFIED AT ENTRY | | PORCH. NEED MASONRY CONNECTOR. SEE | | DETAIL 5/D-1. | | | | 9- REVISE/UPDATE TRUSS ANCHOR SCHEDULE. | | SEE LATEST CATALOGUE THAT WAS REVISED TO | | COMPLY WITH SEC. 1609.4.3 FBC 2001. | | PROVIDE COMPLETE ENGINEERING CALCS FOR | | TYPE AND NUMBER OF NAILS THAT DIFFER | | FROM THOSE TESTED AND PUBLISHED BY THE | | MANUFACTURER. SECTION 104.2.1.2 OF CITY | | AMENDMENTS TO FBC 2001. | | | | 10- A)RIGHT SIDE ELEVATION DOESN'T MATCH | | PLANS. BATHROOM #2 HAS GLASS BLOCK NOT | | WINDOW. | | | | B) SHOW GLASS BLOCK ON LEFT ELEVATION TO | | MATCH PLAN. | | | | 11- CLARIFY IF USING STORM SHUTTERS OR | | IMPACT GLAZING. THEN, PROVIDE COMPLETE | | INFORMATION FOR EITHER METHOD. | | | | 12- PROVIDE FLORIDA/LOCAL PRODUCT | | APPROVAL FOR:A) ONE HOUR FIRE RATED | | ASSEMBLY AT EMERGENCY EGRESS OPENING. | | | | B) SLIDING GLASS DOORS. DRAWINGS | | SUBMITTED DON'T MATCH DADE COUNTY NOA | | SUBMITTED. | | | | C) PROVIDE PRODUCT APPROVAL FOR 12'-0" | | WIDE SLIDING GLASS DOORS. SEE PLANS. | | | | D) LARGE FIXED WINDOWS AS SHOWN ON GREAT | | ROOM. PRODUCT APPROVAL SUBMITTED DOESN'T | | COVER THOSE SIZES. | | | | E) ENTRY DOORS. DRAWINGS SUBMITTED ARE | | FOR 6'-8" HIGH DOORS. SEE PLANS. | | | | F) TRUSS CONNECTORS SPECIFIED ON PLANS. | | AFTER CORRECTIONS TO SPECIFY PROPER | | ANCHORS ARE DONE ON PLANS. | | | | 13- SHEET D-1:A) CONNECTORS CS-16 X | | AND HTS-20 SHOWN ON DETAILS 3, 4 AND 5 | | ARE WOOD TO WOOD CONNECTORS. NEED TO | | SPECIFY MASONRY CONNECTORS. SEE | | CATALOGUE AND REVISE AS REQUIRED. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | B) REVISE TYPE AND NUMBER OF NAILS FOR | | HUS26 CONNECTOR. SEE CATALOGUE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-16 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-16 |
Time |
07:33 |
Sent To |
PC |
|
Notes |
2006-06-16 00:00:00 | ************** UNSAT *********** | | | | 1) NOTE: PLEASE SEE 250.52(5) FOR MIN | | SIZE OF THE GRND ROD. | | SHOWN AS 6 FT, 8FT MIN. | | | | 2) NOTE: PLEASE SEE 424.3B FOR MIN OCP | | TO BE 125% FOR AHU'S. | | PLEASE SEE BOTH UNITS INDICATE 10KW, YET | | THE OCPIS WAY UNDERSIZED. | | PLEASE ALSO SEE 9.8KW LOAD INDICATED FOR | | THE CU#1, WHICH SEEMS HIGH FOR THE OCP | | AS SHOWN. | | | | 3) NOTE: PLEASE SEE BACK COVERED PATIO | | SHALL CONTAIN A MIN LT FIXTURE OF SOME | | SORT FOR EGRESS. | | 210.70, LS 101 7.8, CHAPTER 24. | | | | 4) NOTE: PLEASE SEE A CIRCUIT #38 IS | | STILL BEING SHOWN ON PLANS FOR BATH RM , | | YET PANEL SCHEDULE IS BLANK AT THIS | | LOCATION. | | | | ** SOME OF THESE SAME ITEMS WERE | | REDLINED ON PREVIOUS PLANS. | | | | PLEASE SUBMIT THE ABOVE CORRECTIONS FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-01-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-17 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-17 |
Time |
11:39 |
Sent To |
PC |
|
Notes |
2006-01-17 00:00:00 | REDLINED, | | | | PLANS SHOWS POWDER RM AS CIRCUIT #38, | | HOWEVER PANEL SCHEDULE FOR THIS IS | | BLANK?? |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-13 |
Time |
15:25 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-06-13 |
Time |
15:25 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-26 |
Time |
11:12 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-04-26 |
Time |
11:12 |
Sent To |
M |
|
Notes |
2005-04-26 00:00:00 | ********** UNSAT ************* | | | | 1)NOTE: PLEASE SEE PANEL "A" SHOWS FEED | | TO PANEL "B" AS 100A OCP ON #6 AWG. | | PLEASE SEE 240.4,310.16 AND PLEASE | | CORRELATE WITH RISER DIAGRAM. | | PLEASE ALSO SEE THIS IS SHOWN AS 100A SP | | BRKR ON ONE PHASE? (MISPRINT) | | | | 2)NOTE: PLEASE SEE PANEL "B" SHOWS SUB | | PANEL "C" IN TWO DIFFERENT LOCATIONS? | | PLEASE SEE THIS IS SHOWN ON SAME PHASE. | | PLEASE ALSO CORRELATE AWG FOR 60A OCP. | | SHOWS #6 AND #8? | | PLEASE ALSO SEE SINGLE POLE 60A FOR | | ADDITIONAL SUB PANEL. | | PLEASE SEE 240.4,310.16, 310.15B6 | | | | 3)NOTE: PLEASE SEE NOTE ADDED TO CENTER | | OF PLANS WHICH IS A PROVISO SET UP BY A | | PLAN REVIEWER FOR A PREVIOUS PROJECT. | | THIS COMMENT FROM OTHER ELECTRICAL PLAN | | REVIEW SHOULD NOT BE LOCATED ON THESE | | PLANS. | | PLEASE REMOVE. | | | | 4)NOTE;PLEASE SEE MISSING RECEPT(S) PER | | 210.52 C1, 210.8A6 | | | | 5)NOTE: PLEASE SEE ONE OF THE ABOVE | | CIRCUITS FOR SD'S (#38) IS THE SAME | | CIRCUIT ON PANEL SCHEDULE FOR SUB PANEL | | "B". | | | | 6)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | ON PLANS. | | 215.5 | | | | 7)NOTE: PLEASE SHOW LOADS ON EACH | | ELECTRICAL PANEL. PANEL "B AND "C | | MENTIONS TO SEE LOAD CALCS, HOWEVER | | THESE PANELS NEED TO SHOW ACTUAL LOAD | | FOR THOSE PANELS. | | 220,215.5 | | | | 8 )NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | 9)NOTE: PLEASE SEE PLANS REFERENCE 1999 | | NEC FOR 210.12. WE HAVE BEEN UNDER THE | | 2002 NEC SINCE JULY 1ST, 2003 | | | | 10)NOTE: PLEASE SEE PANEL SCHEDULE | | INDICATES A WHIRLPOOL TUB, YET PLANS DO | | NOT SHOW ANY ELECTRICAL FOR SAME. | | PLEASE SEE 680.24 FOR INDICATION OF GFI | | PROTECTION. | | | | PLEASE BE SURE TO REMOVE ALL OLD VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. | | PLEASE SEE ONE COPY/SET OF OLD SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-14 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-14 |
Time |
11:14 |
Sent To |
E |
|
Notes |
2006-06-14 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-22 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-22 |
Time |
12:48 |
Sent To |
B |
|
Notes |
2006-01-22 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-01-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-06 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-06 |
Time |
09:51 |
Sent To |
E |
|
Notes |
2006-01-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-29 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-29 |
Time |
10:59 |
Sent To |
B |
|
Notes |
2005-12-29 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-19 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-19 |
Time |
09:14 |
Sent To |
B |
|
Notes |
2005-10-19 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-07-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-29 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-29 |
Time |
16:32 |
Sent To |
B |
|
Notes |
2005-07-29 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-06-07 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-06-07 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-06-07 |
Time |
09:40 |
Sent To |
E |
|
Notes |
2005-06-08 00:00:00 | TO 'DP' DESK. RESUB. | 2005-06-07 00:00:00 | LETTERS ARE IN PACKAGE PERMIT #05040909 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-26 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-26 |
Time |
09:20 |
Sent To |
E |
|
Notes |
2005-04-26 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-05-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-05-11 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-04-18 |
Time |
16:48 |
Sent To |
|
|
Notes |
2005-04-18 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-05-02 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-05-02 |
Time |
11:15 |
Rev Time |
0.50 |
Received By |
prafter |
Date |
2005-05-02 |
Time |
11:15 |
Sent To |
B |
|
Notes |
2005-05-02 00:00:00 | MECH PLAN REVIEW: | | | | PROVISO: | | AHU,S REQUIRES AUX. DRAIN PAN WITH | | DRAIN PROTECTION.2000 FBC/M 307.2.3 . | | PAT RAFTER 561/805/6728 OR 805/6719 | | PATTY KRAUSS. | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-20 |
Time |
16:44 |
Rev Time |
0.60 |
Received By |
kstevens |
Date |
2005-06-20 |
Time |
16:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-05-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-05-04 |
Time |
15:36 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-05-04 |
Time |
15:36 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-04-25 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-04-25 |
Time |
18:27 |
Sent To |
I |
|
Notes |
|
|