Plan Review Stops For Permit 05040901 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-28 |
Time |
14:26 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2006-02-28 |
Time |
14:26 |
Sent To |
P |
|
Notes |
2006-02-28 00:00:00 | DRAWING A.1-0 SUBMITTAL. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2006-02-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-13 |
Time |
13:11 |
Rev Time |
0.40 |
Received By |
jgomez |
Date |
2006-02-13 |
Time |
12:53 |
Sent To |
PC |
|
Notes |
2006-02-13 00:00:00 | REVISION RE-SUBMITTAL 2ND CHECKLIST: | | 1- SAME COMMENT FROM PREVIOUS CHECKLIST. | | PLUMBING RISER DIAGRAM IS PART OF THE | | CONSTRUCTION DOCUMENTS AND IT WAS | | CROSSED OUT BY HAND AGAIN. SEE ATTACHED | | COMMENT FROM PREVIOUS CHECKLIST. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2006-01-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-01-17 |
Time |
18:58 |
Rev Time |
0.75 |
Received By |
jgomez |
Date |
2006-01-17 |
Time |
18:58 |
Sent To |
PC |
|
Notes |
2006-01-17 00:00:00 | BUILDING REVISION CHECKLIST; | | 1- DRAWING A-1.0 INCLUDES PLUMBING RISER | | DIAGRAM AND IT WAS CROSS OUT WITH THE | | WORDS NIC. THIS PLUMBING RISER DIAGRAM | | IS PART OF THE CONSTRUCTION DOCUMENTS | | AND IT CAN'T BE CROSSED OUT. RE-SUBMIT | | CLEAN DRAWINGS. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-10 |
Time |
09:29 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-09-21 |
Time |
16:37 |
Sent To |
PC |
|
Notes |
2005-09-21 00:00:00 | CORRECTED DRAWINGS AND REQUESTED PRODUCT | | APPROVALS AND ENERGY CALCULATIONS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-06-30 |
Time |
10:30 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-06-30 |
Time |
10:30 |
Sent To |
PC |
|
Notes |
2005-06-30 00:00:00 | BUILDING REVIEW PROVISO: | | 1- SHUTTERS UNDER A SEPARATE PERMIT. | | 2- NEED REVISED ENERGY CALCULATIONS FOR | | WORST CASE SCENARIO. | | 3- REVISE DOOR/WINDOW SCHEDULE TO MATCH | | PLANS. INCLUDING SYMBOL USED. | | 4- DETAIL 5/D1: CONNECTOR HTS20 CAN'T | | SUPPORT BEAM. REVISE AS REQUIRED. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 5- TRUSS ANCHOR SCHEDULE: UPDATE NAIL | | SIZE USED FOR HUS26. SEE CATALOGUE. | | 6- ROOF FRAMING PLAN: REVISE CONNECTOR | | SPECIFIED AT ENTRY PORCH TO MATCH | | DETAILS 5 & 6 OF DRAWING D-1. | | 7- PROVIDE PRODUCT APPROVAL FOR: | | A) 9'-0" WIDE SLIDING GLASS DOORS. | | B) 8'-0" HIGH ENTRY DOORS. | | 8- SHEET A-5 SHEAR VALUE NOTE: | | A) PROVIDE HAND CALCULATIONS. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | B) WHY USING TIMBER MANUAL TO CALCULATE | | TAPCON VALUES?. | | C) SPECIFY TIMBER MANUAL EDITION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-05-20 |
Time |
07:40 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2005-05-20 |
Time |
07:39 |
Sent To |
PC |
|
Notes |
2005-05-20 00:00:00 | CHECKLIST: | | 1- MEETING WITH RON ELLISH. HE REQUESTED | | TO LOG OUT PLANS TO MAKE REVISIONS BASED | | ON COMMENTS ADDRESSED TO SAME MODEL ON | | PREVIOUS CHECKLISTS. | 2005-05-02 00:00:00 | MECH. PLAN REVIEW: | | | | A/C PLANS DOES NOT MATCH HOUSE PLANS, | | PLEASE SUBMIT CORRECT A/C PLANS. | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | PATTY KRAUSS. | | | | PLEASE IF THEAR ANY QUESTIONS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2006-08-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-03 |
Time |
20:19 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-03 |
Time |
20:19 |
Sent To |
PC |
|
Notes |
2006-08-03 00:00:00 | REDLINED TO VERIFY LOADONCU #1, | | REVISE AS NEEDED AS LOAD IS SHOWN AS | | 9.8KW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-09 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-09 |
Time |
11:30 |
Sent To |
B |
|
Notes |
2006-02-09 00:00:00 | ** REDLINED ** | | | | VERIFY OCP FOR CU, SHOWS 9.8KW, 40A OCP | | | | MIN 8' GROUND ROD REQUIRED PER 250.52A | | | | VERIFY MIN OCP FOR AHU#2, PER 424.3B, | | MIN OCP 125%. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
20:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-03 |
Time |
20:17 |
Sent To |
PC |
|
Notes |
2006-02-03 00:00:00 | REDLINED: | | | | | | MIN OCP FOR AHU#2 SHALL BE SIZED A MIN | | OF 125%. 424.3B | | | | MIN GRND ROD SAHLL BE 8' PER 250.52A5 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-01-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-09 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-09 |
Time |
16:45 |
Sent To |
B |
|
Notes |
2006-01-09 00:00:00 | ********* UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE PANEL "A" IS MISSING | | LOAD FROM PANEL "B"AND "C". | | PLEASE ALSO SEE LOADS ON PANEL "B" AND | | "C". SOME ARE SHOWN WITH 83 KW, 96, KW | | ETC. | | PLEASE ADJUST LOADS AND CALCUALTIONS. | | 220, 215.5 | | | | 2)NOTE: PLEASE SEE MISSING RECEPT PER | | 210.52 DEN | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-13 |
Time |
17:07 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-06-13 |
Time |
17:07 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-26 |
Time |
10:59 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-04-26 |
Time |
10:59 |
Sent To |
M |
|
Notes |
2005-04-26 00:00:00 | ********** UNSAT ************* | | | | 1)NOTE: PLEASE SEE PANEL "A" SHOWS FEED | | TO PANEL "B" AS 100A OCP ON #6 AWG. | | PLEASE SEE 240.4,310.16 AND PLEASE | | CORRELATE WITH RISER DIAGRAM. | | PLEASE ALSO SEE THIS IS SHOWN AS 100A SP | | BRKR ON ONE PHASE? (MISPRINT) | | | | 2)NOTE: PLEASE SEE PANEL "B" SHOWS SUB | | PANEL "C" IN TWO DIFFERENT LOCATIONS? | | PLEASE SEE THIS IS SHOWN ON SAME PHASE. | | PLEASE ALSO CORRELATE AWG FOR 60A OCP. | | SHOWS #6 AND #8? | | PLEASE ALSO SEE SINGLE POLE 60A FOR | | ADDITIONAL SUB PANEL. | | PLEASE SEE 240.4,310.16, 310.15B6 | | | | 3)NOTE: PLEASE SEE NOTE ADDED TO CENTER | | OF PLANS WHICH IS A PROVISO SET UP BY A | | PLAN REVIEWER FOR A PREVIOUS PROJECT. | | THIS COMMENT FROM OTHER ELECTRICAL PLAN | | REVIEW SHOULD NOT BE LOCATED ON THESE | | PLANS. | | PLEASE REMOVE. | | | | 4)NOTE; | | | | 5)NOTE: PLEASE SEE ONE OF THE ABOVE | | CIRCUITS FOR SD'S (#38) IS THE SAME | | CIRCUIT ON PANEL SCHEDULE FOR SUB PANEL | | "B". | | | | 6)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | ON PLANS. | | 215.5 | | | | 7)NOTE: PLEASE SHOW LOADS ON EACH | | ELECTRICAL PANEL. PANEL "B AND "C | | MENTIONS TO SEE LOAD CALCS, HOWEVER | | THESE PANELS NEED TO SHOW ACTUAL LOAD | | FOR THOSE PANELS. | | 220,215.5 | | | | 8 )NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | 9)NOTE: PLEASE SEE PLANS REFERENCE 1999 | | NEC FOR 210.12. WE HAVE BEEN UNDER THE | | 2002 NEC SINCE JULY 1ST, 2003 | | | | PLEASE BE SURE TO REMOVE ALL OLD VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. | | PLEASE SEE ONE COPY/SET OF OLD SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-03 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-03 |
Time |
12:04 |
Sent To |
E |
|
Notes |
2006-02-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-27 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-27 |
Time |
15:57 |
Sent To |
E |
|
Notes |
2006-01-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-12-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-30 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-30 |
Time |
09:20 |
Sent To |
E |
|
Notes |
2005-12-30 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-24 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-24 |
Time |
11:31 |
Sent To |
B |
|
Notes |
2005-08-24 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-06-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-07 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-07 |
Time |
15:37 |
Sent To |
E |
|
Notes |
2005-06-07 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-26 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-26 |
Time |
09:19 |
Sent To |
E |
|
Notes |
2005-04-26 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-05-20 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-04-18 |
Time |
16:44 |
Sent To |
PC |
|
Notes |
2005-04-18 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2005-06-21 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2005-06-21 |
Time |
17:44 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-05-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-05-15 |
Time |
19:44 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2005-05-15 |
Time |
19:44 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-05-02 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-05-02 |
Time |
12:13 |
Rev Time |
0.50 |
Received By |
prafter |
Date |
2005-05-02 |
Time |
12:13 |
Sent To |
P |
|
Notes |
2005-05-02 00:00:00 | MECH. PAN REVIEW: | | | | A/C PLAN DOES NOT MATCH HOUSE PLANS, | | PLEASE SUBMIT CORRECT A/C PLANS. | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | PATTY KRAUSS. | | PLEASE CALL IF THEAR ANY QUESTION. | | MECH. PLAN REVIEW: | | | | A/C PLAN DOES NOT MATCH HOUSE PLANS, | | PLEASE SUBMIT CORRECTED A/C PLANS. | | PAT RAFTER 561/805/6728 OR 805/6719 | | PATTY KRAUSS. | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-28 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-02-28 |
Time |
17:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-06-20 |
Time |
16:51 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2005-06-20 |
Time |
16:51 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-05-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-05-04 |
Time |
15:07 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-05-04 |
Time |
15:07 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-04-25 |
Time |
18:32 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-04-25 |
Time |
18:32 |
Sent To |
I |
|
Notes |
|
|