Plan Review Stops For Permit 05040897 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-01-30 |
Time |
18:14 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-01-30 |
Time |
18:07 |
Sent To |
PC |
|
Notes |
2006-01-30 00:00:00 | BLDG REVISION, DOOR PRODUCT APPROVAL AND | | REVISED ENERGY CALCS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-11-15 |
Time |
14:57 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2005-11-15 |
Time |
14:57 |
Sent To |
PC |
|
Notes |
2005-11-15 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | 1- NOW ENERGY CALCULATIONS WERE REVISED | | USING FBC 2004 FORM. THIS HOUSE WAS | | PERMITTED USING THE FBC 2001 FORMS. | | MIS-MATCHING CODES IS NOT ALLOWED. | | PROVIDE ENERGY CALCS USING THE FBC 2001 | | FORMS AS REQUIRED. | | | | 2- PROVIDE DETAIL 7/D1 AS KEYED ON | | REVISED ROOF FRAMING PLAN. THERE IS NOT | | DETAIL 7 ON SHEET D1. | | | | 3- RESUBMIT FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR ONE HOUR FIRE RATED DOOR AT | | ATRIUM AS SPECIFIED ON PLANS: | | A) DRAWINGS SUBMITTED ARE FOR OUTSWING | | DOORS. NEED INSWING DOOR AS SHOWN ON | | PLANS AND DADE COUNTY NOA #02--0215.03 | | SUBMITTED. | | B) DRAWINGS SUBMITTED ARE FOR 7'-0" | | HIGH DOORS. NEED 8'-0" HIGH DOOR AS | | SHOWN ON PLANS. | | | | 4- APPLY FOR SHUTTERS UNDER A SEPARATE | | PERMIT AS AGREED ON PROVISO DATED 6-9-05 | | TO AVOID DELAYS OR CONFLICTS GIVEN THE | | HIGH VOLUME OF APPLICATIONS AND THE | | SHORTAGE OF REVIEWING PERSONNEL. | | | | ***NOTE: | | STAMPED DRAWINGS AND PRODUCT APPROVAL | | ARE ALREADY APPROVED. CONTRACTOR TO KEEP | | THEM IN THE JOBSITE. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-09-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-09-20 |
Time |
14:14 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2005-09-20 |
Time |
14:14 |
Sent To |
PC |
|
Notes |
2005-09-20 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | 1- ENERGY CALCS WERE REVISED. NOW, THEY | | ARE TAKING THE CEILING FAN CREDIT. | | THEREFORE, NEED TO REVISE THE ELECTRICAL | | PLAN TO SHOW CEILING FAN SIZES IN ALL | | ROOMS AND THE CEILING FANS REQ'D FOR THE | | GREAT RM. SEE TABLE 6-6 CHAPTER 13 FBC. | | REVISION FEES WILL APPLY. | | | | 2- REVISE ROOF FRAMING PLAN AT ENTRY | | PORCH. SHOW CORRECTLY WHEN THERE IS A | | CONCRETE BEAM OR WOOD BEAM. INCLUDING | | THE KNEEWALL AND SPECIFY CORRESPONDING | | CONNECTORS. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC. REVISION FEES APPLY. | | | | 3- REVISE NUMBER OF NAILS SPECIFIED | | FOR HUS26. SEE 2005 CATALOGUE. | | | | 4- PROVIDE PRODUCT APPROVAL FOR ONE HR | | FIRE RATED ATRIUM DOOR THAT MATCHES | | PLANS. | | | | 5- APPLY FOR SHUTTERS PERMIT AS AGREED | | ON PROVISO DATED 6-9-05. | | | | JULIO GOMEZ | | PLANS EXAMINER | | (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-06-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-06-09 |
Time |
17:46 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2005-06-09 |
Time |
17:46 |
Sent To |
E |
|
Notes |
2005-06-09 00:00:00 | BUILDING REVIEW PROVISO: | | 1- SHUTTERS UNDER A SEPARATE PERMIT. | | 2- REVISE ENERGY CALCULATIONS. NEED | | CALCULATIONS DONE TO WORST CASE SCENARIO | | FOR THIS MODEL. | | 3- SUBMIT SOIL TEST REPORT WITH FOOTING | | SIZE REVISION. | | 4- REVISE FRONT ELEVATION TO DELETE 45 | | DEGREEE WINDOWS (TABLE 600 FBC 2001) | | 5- ROOF FRAMING PLAN. REVISE CONNECTOR | | SPECIFIED AT FRONT PORCH MASONRY BEAM. | | NEED MASONRY CONNECTOR. SEE DETAIL 5/D-1 | | 6- TRUSS ANCHOR SCHEDULE:REVISE TYPE OF | | NAIL USED FOR HUS26. SEE CATALOGUE. | | 7- REVISE FRONT ELEVATION SHOWING SOLID | | ENTRY DOOR. SEE PRODUCT APPROVAL. | | 8- PROVIDE PRODUCT APPROVAL FOR ONE HOUR | | FIRE RATED ASSEMBLY EGRESS OPENING. | | 9- PROVIDE PRODUCT APPROVAL FOR 12'-0" | | WIDE SLIDING GLASS DOORS. | | 10- PROVIDE PRODUCT APPROVAL FOR 8'-0" | | HIGH ENTRY DOORS. SUBMITTED 6'-8" DOORS. | | 11- PROVIDE CLEAR WINDOW AND DOORS | | SCHEDULES. NEED MATCHING SYMBOLS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-05-20 |
Time |
07:51 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2005-05-20 |
Time |
07:51 |
Sent To |
PC |
|
Notes |
2005-05-20 00:00:00 | CHECKLIST: | | 1- MEETING WITH RON ELLISH. HE REQUESTED | | TO LOG OUT PLANS TO MAKE CORRECTIONS | | BASED ON PREVIOUS COMMENTS TO SAME | | MODEL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-03 |
Time |
17:23 |
Sent To |
PC |
|
Notes |
2006-02-03 00:00:00 | | | | | 2)NOTE: PLEASE SEE MIN GRND ROD 8' PER | | 250.52A5 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-13 |
Time |
15:44 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-06-13 |
Time |
15:44 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-26 |
Time |
10:50 |
Rev Time |
0.40 |
Received By |
dpalmer |
Date |
2005-04-26 |
Time |
10:50 |
Sent To |
M |
|
Notes |
2005-04-26 00:00:00 | ********** UNSAT ************* | | | | 1)NOTE: PLEASE SEE PANEL "A" SHOWS FEED | | TO PANEL "B" AS 100A OCP ON #6 AWG. | | PLEASE SEE 240.4,310.16 AND PLEASE | | CORRELATE WITH RISER DIAGRAM. | | PLEASE ALSO SEE THIS IS SHOWN AS 100A SP | | BRKR ON ONE PHASE? (MISPRINT) | | | | 2)NOTE: PLEASE SEE PANEL "B" SHOWS SUB | | PANEL "C" IN TWO DIFFERENT LOCATIONS? | | PLEASE SEE THIS IS SHOWN ON SAME PHASE. | | PLEASE ALSO CORRELATE AWG FOR 60A OCP. | | SHOWS #6 AND #8? | | PLEASE ALSO SEE SINGLE POLE 60A FOR | | ADDITIONAL SUB PANEL. | | PLEASE SEE 240.4,310.16, 310.15B6 | | | | 3)NOTE: PLEASE SEE NOTE ADDED TO CENTER | | OF PLANS WHICH IS A PROVISO SET UP BY A | | PLAN REVIEWER FOR A PREVIOUS PROJECT. | | THIS COMMENT FROM OTHER ELECTRICAL PLAN | | REVIEW SHOULD NOT BE LOCATED ON THESE | | PLANS. | | PLEASE REMOVE. | | | | 4)NOTE;PLEASE SEE MISSING RECEPT(S) PER | | 210.52 C1, 210.8A6 | | | | 5)NOTE: PLEASE SEE ONE OF THE ABOVE | | CIRCUITS FOR SD'S (#38) IS THE SAME | | CIRCUIT ON PANEL SCHEDULE FOR SUB PANEL | | "B". | | | | 6)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | ON PLANS. | | 215.5 | | | | 7)NOTE: PLEASE SHOW LOADS ON EACH | | ELECTRICAL PANEL. PANEL "B AND "C | | MENTIONS TO SEE LOAD CALCS, HOWEVER | | THESE PANELS NEED TO SHOW ACTUAL LOAD | | FOR THOSE PANELS. | | 220,215.5 | | | | 8 )NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | 9)NOTE: PLEASE SEE PLANS REFERENCE 1999 | | NEC FOR 210.12. WE HAVE BEEN UNDER THE | | 2002 NEC SINCE JULY 1ST, 2003 | | | | 10)NOTE: PLEASE SEE SD'S ON MULTIPLE | | CIRCUITS WHEN THEY ARE REQUIRED TO BE | | WIRED "INLINE". PLEASE SEE #38 AND 25. | | | | PLEASE BE SURE TO REMOVE ALL OLD VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. | | PLEASE SEE ONE COPY/SET OF OLD SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-27 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-27 |
Time |
15:19 |
Sent To |
E |
|
Notes |
2006-01-27 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-22 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-22 |
Time |
12:51 |
Sent To |
B |
|
Notes |
2006-01-22 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-10-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-14 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-14 |
Time |
10:42 |
Sent To |
B |
|
Notes |
2005-10-14 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-09 |
Time |
18:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-09 |
Time |
18:11 |
Sent To |
B |
|
Notes |
2005-08-09 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-06-08 |
Time |
08:27 |
Sent To |
E |
|
Notes |
2005-06-08 00:00:00 | TO 'DP' DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-26 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-26 |
Time |
09:17 |
Sent To |
E |
|
Notes |
2005-04-26 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-05-20 |
Time |
07:53 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2005-04-15 |
Time |
14:36 |
Sent To |
PC |
|
Notes |
2005-04-15 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-05-02 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-05-02 |
Time |
10:33 |
Rev Time |
0.50 |
Received By |
prafter |
Date |
2005-05-02 |
Time |
10:33 |
Sent To |
B |
|
Notes |
2005-05-02 00:00:00 | MECH. PLAN REVIEW: | | PROVISO: | | AHU #2 REQUIRES AUX. DRAIN PAN WITH | | DRAIN PROTECTION.FBC/M 307.2.3 . | | PAT RAFTER 561/805/6728 OR805/6719 | | PATTY KRAUSS. | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-03-23 |
Time |
12:00 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-03-23 |
Time |
12:00 |
Sent To |
PC |
|
Notes |
2006-03-23 00:00:00 | REVISION: AS BUILT ISOMETRIC SANITARY | | RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2006-03-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-03-21 |
Time |
11:47 |
Rev Time |
1.25 |
Received By |
mperson |
Date |
2006-03-21 |
Time |
11:47 |
Sent To |
PC |
|
Notes |
2006-03-21 00:00:00 | REVISION DENIED | | REFERENCE:FBC-2004 PLUMBING AND CITY OF | | WEST PALM BEACH AMENDMENTS TO FBC-2004 | | CHAPTER 1 | | | | 1. CHAPTER 1, SEC. 106.1 PER CHAPTER | | 481, FLORIDA STATUTES, PART 1, REVISION | | DRAWINGS SHALL BE SIGNED, SEALED, AND | | DATED BY DESIGN PROFESSIONAL, WITH TITLE | | BLOCK. | | 2. ISOMETRIC DRAWING FOR BATHROOM #2 | | DOES NOT REFLECT DRAWING A-2.0. BATHROOM | | #2 IS OFFSET OF LAUNDRY. | | 3. WASHING MACHINE IN LAUNDRY DOES NOT | | REFLECT LAYOUT ON A-2.0. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561)805-6730 | | FAX (561)805-6731 | | UNDERSUPERVISION OF K.STEVENS | | (561)805-6721 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-20 |
Time |
15:44 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2005-06-20 |
Time |
15:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-05-05 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-05-05 |
Time |
14:39 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-05-05 |
Time |
14:39 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-04-25 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-04-25 |
Time |
18:49 |
Sent To |
I |
|
Notes |
|
|