Plan Review Stops For Permit 05040431 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-07-27 |
Time |
14:50 |
Rev Time |
2.00 |
Received By |
shill |
Date |
2005-07-27 |
Time |
14:50 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-07-27 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-07-27 |
Time |
10:20 |
Sent To |
PC |
|
Notes |
2005-07-27 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)CONTRACTOR TO PUT TOGETHER TWO | | COMPLETE PERMIT PACKAGES FOR ISSUANCE. | | OTHERWISE CODE COMPLIANT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-07-20 |
Time |
10:42 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-07-20 |
Time |
10:42 |
Sent To |
PC |
|
Notes |
2005-07-20 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.)ZONING APPROVAL REQUIRED BEFORE A | | PERMIT CAN BE ISSUED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-06-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-10 |
Time |
17:41 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2005-06-10 |
Time |
13:56 |
Sent To |
PC |
|
Notes |
2005-06-10 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)HAVE THE PERMIT SET OF PLANS | | STAMPED BY HISTORIC. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-06-02 |
Time |
16:09 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2005-05-06 |
Time |
09:41 |
Sent To |
PC |
|
Notes |
2005-05-06 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED, FS713.13. | | | | 2.) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | AND THE RECEIPT ATTACHED TO THE | | APPLICATION.561-233-5025 | | | | 3.) A ROOF PERMIT NUMBER WAS NOT | | ASSIGNED.THIS TYPE OF ROOF IS NOT | | WITHIN THE SCOPE OF YOUR GC LICENSE, | | FS489. | | | | 4.)SHOW LANDING DIMENSION FOR STAIRS. | | | | 5.)PROVIDE A STRUCTURAL DETAIL FOR THE | | STAIRS. | | | | 6.)FLORIDA STATE OR LOCAL PRODUCT | | APPROVALS REQUIRED IN ADDITION TO THE | | NOAS PROVIDED, FAC9B72. | | WWW.FLORIDABUILDING.ORG. | | | | 7.)SUBMIT THE FOLLOWING PRODUCT | | APPROVALS: | | FIXED GLASS WINDOW | | MULLION | | | | 8.)CONNECTION DETAIL 5, A7, LUS210-3 | | FASTENING CONFLICTS WITH CATALOG.CHECK | | ALL CONNECTORS.IF YOU SPECIFY | | FASTENING IN CONFLICT WITH | | MANUFACTURER?S SPECIFICATIONS A LOCAL | | PRODUCT APPROVAL IS REQUIRED FAC9B72. | | | | 9.)PROVIDE DRAFTSTOP SCHEDULE, 2ND | | FLOOR FRAMING PLAN, FBC705.3. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-07-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-07-18 |
Time |
06:22 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-07-18 |
Time |
06:04 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-06-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-06-21 |
Time |
12:12 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-06-21 |
Time |
12:02 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-07-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-07-08 |
Time |
12:15 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-07-08 |
Time |
07:00 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-06-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-06-02 |
Time |
16:02 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-06-02 |
Time |
15:15 |
Sent To |
P |
|
Notes |
2005-06-02 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} COMMENTS FROM PRIOR REVIEW, NOTE #3. | | 3/0CU BEING FED WITH A 300 AMP BREAKER | | (OCP) IS IN VIOLATION OF 310.15(B)(6). | | | | 2} THE QUESTION FROM COMMENT #1 STILL | | REMAAINS, IS THE SERVICE EQUIPMENT A | | METER/MAIN, IF SO USE CORRECT DIAGRAM | | FOR SAME, REMOVE THE 2" CONDUIT SHOWN ON | | RISER. IF NOT THE FEEDERS WOULD HAVE TO | | BE 250MCM TO COMPLY WITH 310.15, | | TERMINATING IN A 300 AMP OCP. IF THERE | | ARE QUESTIONS REGARDING THIS ISSUE, CALL | | DEWEY OR MYSELF PRIOR TO REDRAWING AND | | RESUBMITTING. | | | | 3} NOTE #6. CLEARANCE FOR DISCONNECTS AT | | THE CONDENSERS, COMPLY WITH 110.26. | | | | 4} NOTE #12, SUBMIT AIC(FAULT CURRENT) | | RATINGS FOR THE EQUIPMENT PER 110.10. | | | | 5} IF THE OBJECT IN THE KITCHEN THAT | | RESEMBLES A TABLE, IS IN FACT AN ISLAND | | , THE RECEPTACLE MUST BE GFI PER | | 210.8(A)(6). | | | | PLEASE LABEL THE ROOMS ON THE ELECTRICAL | | PLAN PER 104.2.1.3 FBC, CWPB | | AMMENDMENTS. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-04-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-13 |
Time |
18:05 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-04-13 |
Time |
18:05 |
Sent To |
M |
|
Notes |
2005-04-13 00:00:00 | ********* UNSAT ********* | | | | 1)NOTE: PLEASE CLARIFY RISER, IT APPEARS | | TO SHOW A METER/MAIN COMBO?? | | PLEASE SEE RISER APPEARS TO SHOW A FEED | | GOING OUT OF THE TOP OF EQUIPMENT TO A | | SUB-PANEL? | | 215.5 | | PLEASE PROVIDE A PANEL SCHEDULE FOR | | EQUIPMENT OUTSIDE IF INDEED A PANEL. | | | | 2)NOTE: PLEASE CLARIFY IF LOAD SHOWN FOR | | POOL HEATER IS THE LOAD ALREADY FIGURED | | AT 125% FOR CONTINUOUS LOADS. | | 215.3,230.42 ETC. | | | | 3)NOTE: PLEASE SEE RISER SHOWS A 300A | | MAIN WITH NO OCP SHOWN FOR SUB PANEL. | | 300A MAIN ON 2/0'S?? | | 240.4,310.15B6 | | | | 4)NOTE: PLEASE SEE 250.66 FOR MIN | | GROUNDING ELECTRODE CONDUCTOR. #2 MIN | | 310.15B6 | | | | 5)NOTE: PLEASE SEE 210.52D FOR MISSING | | BATH RECEPTS WITHIN 3' OF SINK. | | | | 6)NOTE: PLEASE SEE MISSING A/C | | DISCONNECTS FOR AC/ CU'S AND AHU'S. PER | | 440.11 AND CLEARENCE PER 110.26 | | | | 7)NOTE: PLEASE SHOW ALL RECEPTS SERVING | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | -ED PER 210.8A-6 | | SEE ISLAND. | | | | 8)NOTE: PLEASE SEE 210.8A2 FOR GARAGES. | | | | 9)NOTE: PLEASE SEE PLANS ARE MISISNG ALL | | SERVICE EQUIPMENT?? UNABLE TO REVIEW | | LOCATIONS FOR CODE COMPLIANCE AT THIS | | TIME.215. | | | | 10)NOTE:SMOKE DETECTORS ARE REQUIRED | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | UNIT. | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | TO FLOORS ABOVE AND IN THE VICINITY OF | | BEDROOMS. | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | A MIN OF 3' FROM BATHROOM DOORS AND | | KITCHENS. | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | :PLEASE SEE MISSING SD LEADING TO FLOOR | | ABOVE: | | | | 11)NOTE: PLEASE SEE MISSING FOOTER STEEL | | FOR GROUNDING ELECTRODE REQUIRED. 250.50 | | | | 12)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 | | | | PLEASE SEE MANY OF THE ABOVE ITEMS HAVE | | BEEN REDLINED ON ONE SET OF PLANS. | | | | PLEASE REMOVE ALL OLD VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO TWOM | | COMPLETE SETS FOR REVIEW AND STAMPING. | | ONE SET/COPY OF OLD SHEETS SHOULD BE | | SUBMITTED FOR REFERENCE ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2006-08-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-11 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-11 |
Time |
11:40 |
Sent To |
P |
|
Notes |
2006-08-11 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-07-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-15 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-15 |
Time |
10:20 |
Sent To |
E |
|
Notes |
2006-07-15 00:00:00 | TO "BTROBAUGH" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-14 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-14 |
Time |
10:57 |
Sent To |
E |
|
Notes |
2006-06-14 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-21 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-21 |
Time |
16:00 |
Sent To |
Z |
|
Notes |
2005-07-21 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-01 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-01 |
Time |
16:08 |
Sent To |
E |
|
Notes |
2005-07-01 00:00:00 | TO "BTROBAUG" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-06-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-22 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-22 |
Time |
11:28 |
Sent To |
Z |
|
Notes |
2005-06-22 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-05-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-31 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-31 |
Time |
09:01 |
Sent To |
E |
|
Notes |
2005-05-31 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-05-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-18 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-18 |
Time |
16:33 |
Sent To |
Z |
|
Notes |
2005-05-18 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-04-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-12 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-12 |
Time |
16:03 |
Sent To |
E |
|
Notes |
2005-04-12 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-05-06 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-04-07 |
Time |
09:23 |
Sent To |
|
|
Notes |
2005-04-07 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-04-19 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-04-19 |
Time |
11:41 |
Rev Time |
0.50 |
Received By |
prafter |
Date |
2005-04-19 |
Time |
11:41 |
Sent To |
P |
|
Notes |
2005-04-19 00:00:00 | MECH. PLAN REVIEW. | | | | A/C CONTRACTOR TO SUBMIT A/C PLANS AND | | EQUIPMENT INFORMATION AT A/C PERMIT | | TIME. | | PAT RAFTER 4/19/05 561/6728O OR | | 805/6719 PATTY KRAUSS. | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-09-06 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-09-06 |
Time |
10:15 |
Sent To |
|
|
Notes |
2006-09-06 00:00:00 | REVISION; REVISED SANITARY RISER DIAGRAM | | OK. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-06-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-06-04 |
Time |
14:45 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-06-04 |
Time |
14:45 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-04-23 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-04-23 |
Time |
07:11 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-04-23 |
Time |
07:11 |
Sent To |
B |
|
Notes |
2005-04-23 00:00:00 | INSTALLATION OF FITTINGS FBC 2001 | | SEC 706.3 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2005-07-26 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-07-26 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-07-26 |
Time |
15:09 |
Sent To |
B |
|
Notes |
2005-07-26 00:00:00 | GIVEN TO SAMANTHA HILL |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2005-06-30 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-06-30 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-06-30 |
Time |
14:56 |
Sent To |
I |
|
Notes |
2005-06-30 00:00:00 | DENIED, | | 1. SURVEY & SITEPLAN DOES NOT MATCH. | | 2. NEED TO HAVE SURVEY TO MATCH SITEPLAN | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-05-26 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-05-26 |
Time |
13:16 |
Sent To |
I |
|
Notes |
2005-05-26 00:00:00 | DENIED, | | 1. DRIVEWAY HAS TOO MUCH PAVERS/CONCRETE | | WITHIN THE FIRST 25FT FRONT SETBACK. | | 2. NEED TO REDUCE THE DRIVE FROM 16FT | | WIDE TO 10FT WIDE. | | **MUST HAVE 1000SQ FT OR 75% OF | | LANDSCAPE WITHIN THE FIRST 25FT FRONT | | SETBACK.** | | 3. NEED TO PROVIDE TWO COPY OF SURVEY | | 4. NEED TO PROVIDE THE REAR SETBACK FROM | | THE STRUCTURE TO PROPERTY LINE. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-04-11 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-04-11 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-04-11 |
Time |
15:09 |
Sent To |
I |
|
Notes |
2005-04-11 00:00:00 | DENIED, | | 1. NEED KNOW THE WIDTH OF THE DRIVEWAY. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|