Plan Review Stops For Permit 05031157 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2005-08-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-28 |
Time |
08:06 |
Rev Time |
0.44 |
Received By |
jwitmer |
Date |
2005-08-28 |
Time |
07:42 |
Sent To |
E |
|
Notes |
2005-08-28 00:00:00 | BUILDING PROVISO: | | MANSARD ROOF NOT PART OF THIS PERMIT, | | NO PRODUCT APPROVALS SUBMITTED, NOR | | UNDER THE ROOFING PERMIT . JW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-08-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-13 |
Time |
16:57 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2005-08-13 |
Time |
16:57 |
Sent To |
|
|
Notes |
2005-08-13 00:00:00 | MET WITH ROMAN BUCKNER 8/01/05 HE WAS | | NOT SURE IF THIS JOB WAS USING METAL | | MANSARD WAS GOING TO GET BACK WITH ME? | | JW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-07-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-07-19 |
Time |
17:38 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2005-07-19 |
Time |
17:38 |
Sent To |
|
|
Notes |
2005-07-19 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05031157 | | ADD: 500 PALM STREET STE"C" | | CONT:MIKE MOORE CONST | | TEL: (561)262-0314 | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | | | ""NO ROOFING PRODUCT APPR.SUBMITTED""" | | | | 1) FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | PLANS INDICATE ROOF DAMAGE TO THE | | MANSARD ROOFING, NO PRODUCT INFORMATION | | WAS PROVIDED FOR THE METAL ROOF.NOTE | | THIS IS IN THE FIRE DISTRICT A CLASS A | | OR B ROOF COVERING IS REQUIRED F102.2.4. | | | | 2) THE BUILT UP ROOFING PRODUCT APPROVAL | | SUBMITTED DOESN'T INDICATE WHICH SYSTEM | | IS TO BE USED( FROM FIRST REVIEW). THE | | SECOND ISSUE IS LOW PRESSURES FOR ZONE | | THREE.PLANS INDICATE -68.2 IN ZONE | | THREE. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-04-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-04-18 |
Time |
11:07 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2005-04-18 |
Time |
10:47 |
Sent To |
PC |
|
Notes |
2005-04-18 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 05031157 | | ADD: 500 PALM STREET STE"C" | | CONT:MIKE MOORE CONST | | TEL: (561)262-0314 | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | PLANS INDICATE ROOF DAMAGE TO THE | | MANSARD ROOFING, NO PRODUCT INFORMATION | | WAS PROVIDED FOR THE METAL ROOF.NOTE | | THIS IS IN THE FIRE DISTRICT A CLASS A | | OR B ROOF COVERING IS REQUIRED F102.2.4. | | | | 2) THE BUILT UP ROOFING PRODUCT APPROVAL | | SUBMITTED DOESN'T INDICATE WHICH SYSTEM | | IS TO BE USED. THE SECOND ISSUE IS LOW | | PRESSURES FOR ZONE THREE.PLANS INDICATE | | -68.2 IN ZONE THREE. | | | | 3) THE PLANS INDICATE WOOD ROOF FRAMING | | BUT NO INDICATION IF THIS IS NEW WORK OR | | EXISTING? WHAT TYPE OF SPECIES OF WOOD | | IS USED AND THE GRADE TO DETERMINE THE | | SPANS? PROVIDE LIVE LOAD/ DEAD LOADS AND | | | | DEFLECTION LIMITATION. FL BLD CODE | | 104.2.1.2 ADDITIONAL INFORMATION | | REQUIRED. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-29 |
Time |
07:31 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-08-29 |
Time |
07:27 |
Sent To |
I |
|
Notes |
2005-08-29 00:00:00 | NEW SHEET, NEEDS REVIEW AND STAMPING BY | | OTHER TRADES. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-03-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-03-25 |
Time |
10:41 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-03-25 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-09-08 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-09-08 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2005-04-07 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-04-07 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-04-07 |
Time |
15:26 |
Sent To |
|
|
Notes |
2005-04-07 00:00:00 | 1) ALL CONSTRUCTION, ALTERATION AND | | DEMOLITION SHALL BE IN ACCORDANCE WITH | | NFPA 241. | | | | 2) PLEASE BE ADVISED THAT ALL WORK IS TO | | COMPLY WITH NFPA 101, 2003 EDITION. | | | | | | MIKE WENNERGREN, A/CAPTAIN | | WPBFR(561) 835-2910 OR 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-08-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-19 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-19 |
Time |
14:49 |
Sent To |
B |
|
Notes |
2005-08-19 00:00:00 | TO "COMM" BD#5 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-06-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-28 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-28 |
Time |
11:00 |
Sent To |
|
|
Notes |
2005-07-01 00:00:00 | TO "COMM" BD#27 | 2005-06-28 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-04-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-18 |
Time |
10:47 |
Rev Time |
|
Received By |
jwitmer |
Date |
2005-03-24 |
Time |
10:02 |
Sent To |
|
|
Notes |
2005-03-24 00:00:00 | TO "COMM" BD#61 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-09-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-09-15 |
Time |
07:14 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2005-09-15 |
Time |
06:31 |
Sent To |
|
|
Notes |
2005-09-15 00:00:00 | PLEASE NOTE - A/C CONTRACTOR INDICATED | | ON THE APPLICATION IS NOT CURRENTLY | | REGISTERED WITH THE STATE.A/C PERMIT | | WILL HAVE TO BE APPLIED FOR SEPARATELY | | BY A STATE REGISTERED OR LICENSED | | CONTRACTOR. | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | IF YOU HAVE ANY OTHER QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-04-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-04-13 |
Time |
07:34 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2005-04-13 |
Time |
07:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2005-09-18 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-09-18 |
Time |
01:26 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-09-18 |
Time |
01:26 |
Sent To |
|
|
Notes |
2005-09-18 00:00:00 | STAMPED NEW SHEET |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-07-30 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-07-30 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-07-30 |
Time |
09:53 |
Sent To |
|
|
Notes |
2005-07-30 00:00:00 | ROOF: | | EXISTING GUTTER ANSD DOWN SPOUTS, NO | | PARAPET.PES |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-03-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-03-26 |
Time |
14:19 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2005-03-26 |
Time |
14:19 |
Sent To |
|
|
Notes |
2005-03-26 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) MORE INFORMATION FOR ROOF DRAINAGE IS | | REQUIRED. SUBMIT CALCULATIONS FOR | | PRIMARY AND SECONDARY ROOF DRAINS. SHOW | | THE SQUARE FOOTAGE OF THE ROOF AND SHOW | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | PARAPETS. INDICAT SQUARE FOOTAGE TO BE | | DRAINING INTO THE PRIMARY ROOF DRAIN. | | ONLY ONE ROOF DRAIN SHOWN. SHOW THE SIZE | | OF THE NEW OVERFLOW SCUPPER AND | | DOWNSPOUT. SECTIONS 1106 & 1107 AND ALL | | SUBSECTIONS AND TABLES. | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|