Plan Review Details - Permit 05030626
Plan Review Stops For Permit 05030626
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2005-06-07 Cont ID  
Sent By jwitmer Date 2005-06-07 Time 07:02 Rev Time 0.00
Received By jwitmer Date 2005-12-08 Time 10:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2006-04-03 Cont ID  
Sent By jwitmer Date 2006-04-03 Time 13:28 Rev Time 0.77
Received By jwitmer Date 2006-04-03 Time 13:28 Sent To PC
Notes
2006-04-03 00:00:00REVISION: 16' WIDE ROLL UP DOOR
 03-0722.04

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2006-02-03 Cont ID  
Sent By jwitmer Date 2006-02-03 Time 14:03 Rev Time 0.55
Received By jwitmer Date 2006-02-03 Time 14:03 Sent To PC
Notes
2006-02-03 00:00:00WINDOW REVISION YKK YHS-50 ALUMINIUM
 GLAZED STOREFRONT SYSTEM -IMPACT

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2006-01-19 Cont ID  
Sent By jwitmer Date 2006-01-19 Time 08:25 Rev Time 0.55
Received By jwitmer Date 2006-01-19 Time 08:25 Sent To PC
Notes
2006-01-19 00:00:00REV: CHANGE PRODUCT APPROVAL MIAMI-DADE
 03-0722.04 NO FL APPROVAL WILL REQUIRE
 LOCAL APPROVAL SENT LOCAL COVERSHEET.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-01-19 Cont ID  
Sent By jwitmer Date 2006-01-19 Time 08:23 Rev Time 0.44
Received By jwitmer Date 2006-01-19 Time 08:23 Sent To PC
Notes
2006-01-19 00:00:00CHANGE OF PRODUCT APPROVAL:
 2001- FL 3101/ 02-0328.03 NOA

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-12-08 Cont ID  
Sent By jwitmer Date 2005-12-08 Time 10:04 Rev Time 0.77
Received By jwitmer Date 2005-12-08 Time 10:04 Sent To PC
Notes
2005-12-08 00:00:00REVISION # 1 ANCHOR BOLTS 11-22-05JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-11-30 Cont ID  
Sent By jwitmer Date 2005-11-30 Time 11:11 Rev Time 1.11
Received By jwitmer Date 2005-11-30 Time 11:11 Sent To PC
Notes
2005-11-30 00:00:00CANOPY FOOTER REVISIONS11-30-05 JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-08-07 Cont ID  
Sent By jwitmer Date 2005-08-07 Time 07:39 Rev Time 1.25
Received By jwitmer Date 2005-08-07 Time 06:37 Sent To  
Notes
2005-08-07 00:00:008-07-05 PLANS REVIEWED, CORRELATED &
 STAMPED JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-06-07 Cont ID  
Sent By jwitmer Date 2005-06-07 Time 08:04 Rev Time 2.22
Received By jwitmer Date 2005-06-07 Time 07:02 Sent To  
Notes
2005-06-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05030626
 ADD: 2505 BRISTOL DRIVE
 CONT:PLAN REVIEW
 TEL: (561)684-5449#209
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 1)PROVIDE NOC RECORDED WITH THE CLERK OF
 COURT BEFORE A PERMIT CAN BE ISSUED.
 ***NOTE, ONCE THE NOTICE OF COMMENCEMENT
 IS RECORDED WORK MUST BE COMMENCED OR BE
 RE-RECORDED.****
  
 2) 471.023 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ENGINEER
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ENGINEERING SERVICES, SHALL INCLUDE THE
 CERTIFICATE OF AUTHORIZATION NUMBER.
 ADD THE NUMBER TO EACH SHEET.THIS MAY
 BE ADDED BY HAND.
  
 3) 481.219 F. S. CERTIFICATE OF
 AUTHORIZATION SHALL BE REQUIRED ALSO FOR
 ARCHITECTS WHEN USING A FICTIOUS NAME.
  
 4) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:(ALL REQUIRE FL COVERSHEET)
 A) ROLL UP DOOR- LOW PRESSURE 33LBS SEE
 A-3.0 FOR REQUIRED PRESSURE OF -53
 B) LOUVER DOOR- INGERSOLL-RAND - LOW
 PRESSURE -60 LBS REQUIRED -61.
 C)SOLID DOOR- CURRIES ASSA ABLOY LOW
 PRESSURE -57.2 REQUIRED PRESSURE -61
 LBS
 D) WINDOWS NOTHING SUBMITTED
 E) STORM SHUTTERS-FL COVERSHEET
 F) ROOFING ASSEMBLIES- NOTHING
 SUBMITTED
  
 6)COMMENT # 6 FROM THE PREVIOUS REVIEW
 DEALS WITH THE SAME ISSUE, 11-4.24.2
 SINKS, HEIGHT. SINKS SHALL BE MOUNTED
 WITH THE COUNTER NO HIGHER THAN 34"
 ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARENCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
 THE PLANS INDICATE THE CLEAR KNEE
 SPACE, BUT THE HEIGHT REQUIREMENT IS NOT
 INDICATED AT 34". DETAIL# 7 DOES
 INDICATE HEIGHT FOR THE RESTROOM LAV,
 INDICATE HEIGHT FOR THE SINK IN THE
 BREAK ROOM!
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-04-11 Cont ID  
Sent By jwitmer Date 2005-04-11 Time 10:04 Rev Time 5.55
Received By jwitmer Date 2005-04-11 Time 09:51 Sent To  
Notes
2005-04-11 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05030626
 ADD: 2505 BRISTOL DRIVE
 CONT:PLAN REVIEW
 TEL: (561)684-5449#209
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 DISCREPANCY BETWEEN THE VICINITY MAP
 SHEET A0.1 INDICATING THE SITE AND THE
 PLAT MAP.
  
 2)PROVIDE NOC RECORDED WITH THE CLERK OF
 COURT BEFORE A PERMIT CAN BE ISSUED.
 ***NOTE, ONCE THE NOTICE OF COMMENCEMENT
 IS RECORDED WORK MUST BE COMMENCED OR BE
 RE-RECORDED.****
  
 3) THE STRUCTURAL PLANS S-4 INDICATE THE
 USE OF MANUFACTURED METAL BUILDINGS, NO
 DRAWINGS WERE SUPPLIED.PLANS ARE TO
 INDICATE WIND ZONE AND DESIGN CRIERIA.
  
 4)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) ROLL UP DOORS
 B) EXTERIOR SWING DOORS, SOLID &
 LOUVERED
 C) WINDOWS
 D) STORM SHUTTERS
 E) ROOFING ASSEMBLIES
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5) INDICATE THE PRESSURES FOR THE
 WINDOWS AND DOORS OF THE ENCLOSED
 STURURE?
  
 6) SEE SHEET A6.0 DETAIL# 1 BREAKROOM
 ELEVATIONS INDICATE SECTION# 7 FOR
 HEIGHT DETAILS.PLEASE MAKE CORRETIONS.
 11-4.24.2 SINKS, HEIGHT. SINKS SHALL
 BE MOUNTED WITH THE COUNTER NO HIGHER
 THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARENCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
  
 7) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED, SHEET
 A2.0 INDICATES FLOOR PLAN NOTES, PLANS
 INDICATE VARIOUS NUMBERED DETAILS BUT NO
 NOTES FOLLOW, EXAMPLE 2-4 OR 6-7?
  
 8)MECH TABLE 403.4.2 PUBLIC SPACES,
 TOLIET ROOMS/ 50 CFM/ WATER CLOSET
 FOOTNOTE "B" EXHAUST REQUIRED &
 RECIRCULATION OF AIR IS PROHIBITED.
  
 9) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITLY KNOWN OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-04-24 Cont ID  
Sent By dpalmer Date 2006-04-24 Time 15:55 Rev Time 0.00
Received By dpalmer Date 2006-04-24 Time 15:55 Sent To PC
Notes
2006-04-24 00:00:00PLEASE SEE PAPAERWORK AND PLANS
 SUBMITTED FOR EXISTING LIGHTING POLES TO
 REMAIN.
 ALL FUTURE LTS TO BE APPLIED FOR AND
 REVIEWED UNDER A SEPARATE PERMIT.
 EXISTING POLES ON-SITE TO REMAIN, NO
 CHANGES ARE TO BE MADE.

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2006-03-27 Cont ID  
Sent By dpalmer Date 2006-03-27 Time 12:54 Rev Time 0.00
Received By dpalmer Date 2006-03-27 Time 12:54 Sent To PC
Notes
2006-03-27 00:00:00*** UNSAT ***
  
  
 1) NOTE: PLEASE SUBMIT WIND LOAD
 CALCUALTIONS FOR POLES AND LIGHTING
 FIXTURES ATTACHED. PLEASE SEE THESE MUST
 BE SIGNED, DATED AND SEAL BY A FL
 LICENSED PE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW.
  
 DEWEYPALMER
 561-805-6717

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-03-27 Cont ID  
Sent By dpalmer Date 2006-03-27 Time 12:53 Rev Time 0.00
Received By dpalmer Date 2006-03-27 Time 12:53 Sent To PC
Notes
2006-03-27 00:00:00REV'S FOR 1.2,2.2 OK,
  
 CALCS FOR LIGHTING POLES WITH FIXTURES
 PENDING.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-07-27 Cont ID  
Sent By dpalmer Date 2005-07-27 Time 15:52 Rev Time 1.50
Received By dpalmer Date 2005-07-27 Time 14:54 Sent To  
Notes
2005-07-27 00:00:00ELECTRICAL PLANS STAMPED.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-05-16 Cont ID  
Sent By dpalmer Date 2005-05-16 Time 16:28 Rev Time 2.50
Received By dpalmer Date 2005-05-16 Time 14:12 Sent To  
Notes
2005-05-16 00:00:00********** UNSAT 2ND REVIEW ***********
  
 PLANS SUBMITTED FOR "PLAN REVIEW" ONLY
 AND NOT SUBMITTED FOR PERMIT.
  
 1)NOTE: PLEASE SEE NOTE #1 FROM PREVIOUS
 REVIEW.
 PLEASE SEE MISSING INFORMATION ON TITLE
 BLOCKS FOR P,M,E, ARCH SHEETS AND FS
 SHEETS ALSO. PLEASE SEE ANY OTHER SHEETS
 WHICH POSSIBLY MAY ALSO HAVE MISSING
 REQUIRED LICENSE INFORMATION.
 PLEASE SEE FAC 61G1-16.004, FAC
 61G15-23.002.
 REQUIRED PER FS 481.219, 471.023
 THIS INFORMATION IS REQUIRED FOR ALL
 SHEETS AND FOR ALL TRADES WHEATHER OR
 NOT COMMENT IS MADE BY OTHER
 REVIEWER(S).
 PLEASE SEE THIS WAS NOTED ON PREVIOSU
 REVIEW AND RESPONSE LTR MENTIONS: "PLANS
 CORRECTED TO INCLUDE THE PRINTED NAME
 AND SIGNATURE OF PERSON RESPONSIBLE FOR
 PLANS". THIS IS REQUIRED ALSO UNDER FBC
 104.2.1, HOWEVER THIS IS NOT THE ONLY
 ITEM WHICH WAS NOTED.
  
 2)NOTE: PLEASE PORVIDE WIND LOADING FOR
 LIGHT POLES AND FIXTURES PER FBC 140
 MPH.
 THIS IS REQUIRED AT THIS TIME IF SITE
 LIGHTING IS UNDER THIS PERMIT.
  
 3)NOTE: PLEASE SEE 250.6,250.24
 EQUIPMENT GROUNDING CONDUCTORS SHALL NOT
 BE INSTALLED UNTIL AFTER THE FIRST MEANS
 OF DISCONNECT.
  
 4)NOTE: PLEASE CORRELATE FS PLANS WITH
 E-SHEETS.
 PLEASE SEE FS PANEL INDICATE BEING FED
 FROM PANEL LA??
 PLEASE SEE PANELS SHOWN ON FS SHEETS DO
 NOT CORRELATE WITH E-SHEETS??
 SC, DHI ETC?
 215.5
  
 5)NOTE: PLEASE SEE DISCONNECTING MEANS
 FOR DETACHED STRUCTURES PER
 225.31-225.36 FUEL CANOPY
  
 6)NOTE: PLEASE SEE 250.32 FOR GROUNDING
 ELECTRODE CONNECTION AT DETACHED
 STRUCTURES.
  
 7)NOTE: PLEASE PROVIDE POSSIBLE CLASS
 LOCATION FOR SERVICE BAY AREAS.
 PLEASE SEE POSSIBLE EXEMPTIONS IN NEC
 511.
 PLEASE PROVIDE NOTES ON PLANS FOR
 USEAGE/CLASS. SEE POSSIBLE NOTES FROM
 OTHER TRADES.
 PLEASE SEE POSSIBLE AIR CHANGES.
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
 PLEASE SUBMIT ONLY ONE SET OF OLD/VOIDED
 SHEETS FOR REFERENCE ONLY.
  
 PLEASE SEE POSSIBLE COMMMENTS FROM OTHER
 TRADES WHICH MAY HAVE AN AFFECT ON
 ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-03-18 Cont ID  
Sent By dpalmer Date 2005-03-18 Time 07:54 Rev Time 1.00
Received By dpalmer Date 2005-03-18 Time 07:39 Sent To  
Notes
2005-03-18 00:00:00*********** UNSAT ************
  
 ** PLEASE SEE PLANS WERE SUBMITTED FOR
 "PLAN REVIEW" ONLY AT THIS TIME AND HAVE
 NOT BEEN SUBMITTED FOR PERMIT.
  
  
 1)NOTE: PLEASE SEE MISSINGLICENSE
 INFORMATION REQUIRED ON TITLE BLOCK FOR
 ARCHITECTUAL AND ENGINEERING FIRM(S).
 PLEASE ALSO SEE OTHER INFORMATION
 REQUIRED ON TITLE BLOCKS.
 PLEASE SEE FAC 61G1-16.004,(ARCH) FAC
 61G15-23.002 (ENG) REQUIRED PER FS
 481.219, FS 471.023.
 PLEASE SEE THIS IS REQUIRED ON ALL
 SHEETS AND FOR ALL TRADES WHEATHER OR
 NOT COMMENT IS MADE BY OTHER
 REVIEWER(S).
  
 2)NOTE: PLEASE SEE PLANS INDICATEA NEW
 GAS CANOPY FUELING STATION AND A NEW
 CARWASH/SERVICE BLDG.
 PLEASE SEE NO ELECTRICAL PLANS WERE
 SUBMITTED FOR LIGHTING , RECEPTS, RISER
 DIAGRAM, FEEDERS, GROUNDING, ETC.
 PLEASE SHOW ALL CIRCUITING ON PLANS AND
 CORRELATE WITH PANEL SCHEDULES TO BE
 SUBMITTED.
  
 PLEASE SEE DUE TO COMPLETE ELECTRICAL
 PLANS NOT BEING SUBMITTED AT THIS TIME,
 A COMPLETE AND FULL REVIEW CAN NOT BE
 DONE.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2005-12-07 Cont ID  
Sent By mamini Date 2005-12-07 Time 10:11 Rev Time 0.50
Received By mamini Date 2005-12-07 Time 10:11 Sent To  
Notes
2005-12-07 00:00:00PASSED:
  
 1. REVIEWED FOR REVISION, SHEETS C-5,
 C-10, C-13.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2005-05-12 Cont ID  
Sent By mamini Date 2005-05-12 Time 08:49 Rev Time 1.00
Received By mamini Date 2005-05-12 Time 08:49 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2005-03-22 Cont ID  
Sent By mamini Date 2005-03-22 Time 09:52 Rev Time 1.00
Received By mamini Date 2005-03-22 Time 09:52 Sent To  
Notes
2005-03-22 00:00:00FAILED:
  
 1. DUMPSTER ENCLOSURE MUST BE SIZED PER
 CITY OF WPB'S REQUIREMENTS IF GARBAGE
 IS TO BEPICKED UP BY THE CITY ;12'-6"
 OPENING BETWEEN THE GATE POSTS, INRERIOR
 DIMENSIONS 12'-6" WIDE, 12'-0" DEEP.
 PLEASE COORDINATE WITH ARCHITECT.
 2. DRIVEWAY APPROACHES MUST BE
 CONSTRUCTED WITH 6" CONCRETE THICK, FROM
 THE EDGE OF THE PAVEMENT TO THE PROPERTY
 LINE, CITY REQUIREMENT.
 3. PLEASE SUBMIT STORM WATER CALCULATION
 INCLUDING PERVIOUS AND IMPERVIOUS AREA
 FOR THE TOTAL SITE.
 4. PLEASE NOTE THAT CIVIL PLAN MUST BE
 REVIEWED AND APPROVED BY THE PUBLIC
 UTILITIES AND ENGINEERING FOR ALL THE
 CONNECTIONS TO THE SERVICES.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2005-08-15 Cont ID  
Sent By mwennerg Date 2005-08-15 Time 13:20 Rev Time 0.00
Received By mwennerg Date 2005-08-15 Time 13:20 Sent To  
Notes
2005-08-15 00:00:00PASSED ON 6/1/05

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-06-01 Cont ID  
Sent By mwennerg Date 2005-06-01 Time 14:10 Rev Time 0.00
Received By mwennerg Date 2005-06-01 Time 14:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-04-05 Cont ID  
Sent By mwennerg Date 2005-04-05 Time 10:22 Rev Time 0.00
Received By mwennerg Date 2005-04-05 Time 10:22 Sent To  
Notes
2005-04-05 00:00:001) AN ADDRESS NUMBER IS REQUIRED THAT IS
 AT LEAST 6" IN HEIGHT AND CONTRASTING TO
 THE BACKGROUND.
  
 2) HOW WILL EMERGENCY ACCESS THROUGH THE
 EXISTING ENTRANCE GATE BE ACCOMPLISHED
 AFTER NORMAL WORKING HOURS?
  
 3) APPROPRIATE WARNING SIGNS MUST BE
 DISPLAYED IN THE FUEL DISPENSING AREA.
  
 4) PLEASE INCLUDE ADDITIONAL INFORMATION
 AND PRODUCT SHEETS ON TYPES OF FUEL
 BEING USED.
  
 5) PLANS DON'T SHOW ANY EMERGENCY
 LIGHTING. DOES THE STRUCTURE MEET THE
 EXCEPTION TO ELLIMINATE THESE LIGHTS?
  
  
 MIKE WENNERGREN, A/CAPTAIN
 WPBFR(561) 835-2910
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2006-04-18 Cont ID  
Sent By adarroug Date 2006-04-18 Time 16:50 Rev Time 0.00
Received By adarroug Date 2006-04-18 Time 16:50 Sent To E
Notes
2006-04-18 00:00:00TO "DPALMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2006-03-24 Cont ID  
Sent By dpalmer Date 2006-03-24 Time 14:21 Rev Time 0.00
Received By dpalmer Date 2006-03-24 Time 14:21 Sent To B
Notes
2006-03-24 00:00:00TO JW'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2006-03-23 Cont ID  
Sent By dpalmer Date 2006-03-23 Time 08:44 Rev Time 0.00
Received By dpalmer Date 2006-03-23 Time 08:44 Sent To P
Notes
2006-03-23 00:00:00TO KS'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2006-03-23 Cont ID  
Sent By dpalmer Date 2006-03-23 Time 08:43 Rev Time 0.00
Received By dpalmer Date 2006-03-23 Time 08:43 Sent To E
Notes
2006-03-23 00:00:00TO DP'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-03-06 Cont ID  
Sent By adarroug Date 2006-03-06 Time 16:40 Rev Time 0.00
Received By adarroug Date 2006-03-06 Time 16:40 Sent To E
Notes
2006-03-06 00:00:00TO "E" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-02-02 Cont ID  
Sent By adarroug Date 2006-02-02 Time 19:10 Rev Time 0.00
Received By adarroug Date 2006-02-02 Time 19:10 Sent To B
Notes
2006-02-02 00:00:00TO "JWITMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2005-12-20 Cont ID  
Sent By adarroug Date 2005-12-20 Time 11:08 Rev Time 0.00
Received By adarroug Date 2005-12-20 Time 11:08 Sent To P
Notes
2005-12-20 00:00:00TO "P" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-12-20 Cont ID  
Sent By adarroug Date 2005-12-20 Time 11:03 Rev Time 0.00
Received By adarroug Date 2005-12-20 Time 11:03 Sent To B
Notes
2005-12-20 00:00:00TO "JWITMER" DESK/2 SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-12-20 Cont ID  
Sent By adarroug Date 2005-12-20 Time 10:56 Rev Time 0.00
Received By adarroug Date 2005-12-20 Time 10:56 Sent To M
Notes
2005-12-20 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-12-05 Cont ID  
Sent By adarroug Date 2005-12-05 Time 16:36 Rev Time 0.00
Received By adarroug Date 2005-12-05 Time 16:36 Sent To B
Notes
2005-12-05 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-11-17 Cont ID  
Sent By adarroug Date 2005-11-17 Time 13:39 Rev Time 0.00
Received By adarroug Date 2005-11-17 Time 13:39 Sent To B
Notes
2005-11-17 00:00:00TO "JWITMER" DESK/2 REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-09-01 Cont ID  
Sent By adarroug Date 2005-09-01 Time 15:38 Rev Time 0.00
Received By adarroug Date 2005-09-01 Time 15:38 Sent To P
Notes
2005-09-01 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-27 Cont ID  
Sent By adarroug Date 2005-07-27 Time 13:55 Rev Time 0.00
Received By adarroug Date 2005-07-15 Time 16:18 Sent To  
Notes
2005-08-15 00:00:00PLANS ARE IN ZONING IN-BOX
2005-07-19 00:00:00TO "COMM" BD#62
2005-07-15 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-17 Cont ID  
Sent By shill Date 2005-06-17 Time 09:46 Rev Time 0.00
Received By shill Date 2005-06-17 Time 09:46 Sent To Z
Notes
2005-06-17 00:00:00TAKEN OFF OF COMMERCIAL BOARD, ROUTED TO
 ZONING BOX (LAST REVIEW)

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-11 Cont ID  
Sent By adarroug Date 2005-05-03 Time 13:07 Rev Time 0.00
Received By adarroug Date 2005-05-03 Time 14:52 Sent To  
Notes
2005-05-11 00:00:00TO "COMM" BD#63
2005-05-03 00:00:00IN INCOMING, AWAITING SPOT ON "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-04-11 Cont ID  
Sent By pkrauss Date 2005-04-11 Time 14:31 Rev Time 0.00
Received By pkrauss Date 2005-03-17 Time 08:03 Sent To  
Notes
2005-03-17 00:00:00TO "COMM" BD#29

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-12-20 Cont ID  
Sent By tgordon Date 2005-12-20 Time 16:17 Rev Time 0.30
Received By tgordon Date 2005-12-20 Time 16:17 Sent To  
Notes
2005-12-20 00:00:00REVIEW SUBMITTALS FOR HVAC.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-07-27 Cont ID  
Sent By pkrauss Date 2005-07-27 Time 16:55 Rev Time 0.45
Received By pkrauss Date 2005-07-27 Time 16:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2005-06-14 Cont ID  
Sent By pkrauss Date 2005-06-14 Time 19:38 Rev Time 0.55
Received By pkrauss Date 2005-06-14 Time 19:08 Sent To  
Notes
2005-06-14 00:00:00DENIED:
 ****PLAN CHECK ONLY NOT FOR PERMIT****
 PLANS ARE "TECHNICALLY CODE COMPLIANT.
 TITLE BLOCK INFORMATION - CERTIFICATE OF
 AUTHORIZATION NUMBER FOR PARTNERSHIP
 REQUIRED IN ACCORDANCE WITH FS 471.023,
 FS 481.219.
  
 PLANS ARE OTHERWISE CODE COMPLIANT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-04-11 Cont ID  
Sent By pkrauss Date 2005-04-11 Time 13:58 Rev Time 0.55
Received By pkrauss Date 2005-04-11 Time 13:58 Sent To  
Notes
2005-04-11 00:00:00DENIED:
 1.PLANS FOR THE UNDERGROUND FUEL TANKS
 SHALL BE SUBMITTED TO DEPARTMENT OF ERM
 LOCATED AT; 3323 BELVEDERE RD. BUILDING
 #502.PLANS TO HAVE ERM'S APPROVAL
 PRIOR TO REVIEW BY CITY OF WEST PALM
 BEACH.FOR ADDITIONAL QUESTIONS FOR
 ERM, PLEASE CONTACT CHIP GREEN AT
 (561)233-2504.
  
 2.PLAN SHEET A3.0 NOTE #11, INDICATES
 A/C BY OTHERS.PLEASE PROVIDE THE
 FOLLOWING INFORMATION:
 1) EQUIPMENT SCHEDULE, A/C EQUIPMENT,
 AND EXHAUST FANS.
 2) INDICATE WHAT TYPE OF "SERVICE" WORK
  
 WILL DONE IN THE GARAGE AREA.
 3) INDICATE ALL LOUVERED DOORS OR WALL
 LOUVERS.
 ADDITIONAL PERMIT REQUIRED FOR FUEL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 6 Status P Date 2006-03-24 Cont ID  
Sent By kstevens Date 2006-03-24 Time 07:30 Rev Time 0.00
Received By kstevens Date 2006-03-24 Time 07:30 Sent To  
Notes
2006-03-24 00:00:00REVISION APPROVED
  
 CHANGED ROUTING OF PIPING FROM SAND/OIL
 INTERCEPTORS

Review Stop P PLUMBING
Rev No 5 Status P Date 2006-01-24 Cont ID  
Sent By jleech Date 2006-01-24 Time 09:04 Rev Time 0.50
Received By jleech Date 2006-01-24 Time 09:04 Sent To  
Notes
2006-01-24 00:00:00SUBMITAL FIXTURES TO BE USED OK

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-09-07 Cont ID  
Sent By kstevens Date 2005-09-07 Time 11:20 Rev Time 3.00
Received By kstevens Date 2005-09-07 Time 11:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2005-08-12 Cont ID  
Sent By kstevens Date 2005-08-12 Time 17:26 Rev Time 1.15
Received By kstevens Date 2005-08-12 Time 17:26 Sent To  
Notes
2005-08-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 A. FROM PREVIOUS REVIEW:
 1B) SHT PE.1 SANITARY RISER DIAGRAM, A
 FUNNEL FLOOR DARAIN IS NOT AN APPROVED
 INDIRECT WASTE RECEPTOR. PER SECTIONS
 802.3 & 802.3.2 EITHER A FLOOR SINK OR A
 HUB DRAIN IS REQUIRED. RESPONSE NOTED,
 BUT THIS JURISDICTION DOES NOT APPROVE A
 FLOOR DRAIN AS AN INDIRECT WASTE
 RECEPTOR, AND THE CODE STATES "AN
 APPROVED WASTE RECEPTOR"
 2B) SHT PE.1 SANITARY RISER DIAGRAM. THE
 BREAK ROOM SINK SHALL NOT DRAIN THROUGH
 THE HORIZONTAL WET VENT OF THE BATHROOM
 FIXTURES. THE SINK SHALL DISCHARGE
 DOWNSTREAM OF THE BATHROOM FIXTURES.
 SECTION 909.1. RESPONSE NOTED, BUT
 SECTION 908.1 READS " AN INDIVIDUAL VENT
 IS PERMITTED TO VENT TWO TRAPS OR
 TRAPPED FIXTURES AS A COMMON VENT". AS
 THE FLOOR DRAIN HAS A TRAP, A SEPARATE
 STACK WITH A VENT IS REQUIRED FOR THE
 BREAK ROOM SINK.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-06-04 Cont ID  
Sent By kstevens Date 2005-06-04 Time 18:12 Rev Time 2.59
Received By kstevens Date 2005-06-04 Time 18:12 Sent To  
Notes
2005-06-04 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
 CITY CODE
  
 A. FROM PREVIOUS REVIEW:
  
 2) ALL ARCHITECTURAL SHEETS, THE PRINTED
 NAME AND CERTIFICATE OF AUTHORIZATION IS
 REQUIRED ON EACH SHEET PER FAC
 61G1-16.004(2) & (6) AND FS 481.219 &
 481.2055. - RESPONSE NOTED, BUT COMMENT
 NOT ADDRESSED.
 3) ALL SHEETS WITH CRAVEN THOMPSON &
 ASSOCIATES, (CIVIL), REQUIRE A
 CERTIFICATE OF AUTHORIZATION NUMBER IN
 THE TITLE BLOCK. FAC 61G15-23.002(2) &
 FS 471.025. - RESPONSE NOTED, BUT
 COMMENT NOT ADDRESSED.
 5) A DRINKING FOUNTAIN IS REQUIRED PER
 TABLE 403.1. - RESPONSE NOTED AS "A
 BOTTLE OF WATER", BUT A BOTTLED WATER
 COOLER ARI-1010 COMPLIANT IS REQUIRED IF
 A DRINKING FOUNTAIN IS NOT INSTALLED.
 SUBMIT MANUF. SPECIFICATION SHEETS THE
 BOTTLED WATER COOLER. SECTION 410.1
 6) SHT A5.0 SHEET IS "NOT" SIGNED,
 SEALED, OR DATED AS REQUIRED BY FAC
 61G1-16.004(5) AND FS 481.2055. - NO
 RESPONSE BECAUSE I FORGOT TO ADD "NOT".
 7) SHT A6.0 DETAIL #1 PER THE BUILDING
 OFFICIAL NO CABINET DOORS ALLOWED IN THE
 CLEAR FLOOR SPACE), AND FAUCETS
 11-4.24.7. REQUIRED ON PLANS
 TO SHOW COMPLIANCE. - RESPONSE NOTED,
 BUT NOT ALL SECTIONS ADDRESSED.
 8) ALL FS SHEETS, A CERTIFICATE OF
 AUTHORIZATION IS REQUIRED ON THE TITLE
 BLOCK ON EACH SHEET. ALSO THE SEAL AND
 SIGNATURE SHALL BE DATED WHEN SEAL AND
 SIGNATURE ARE AFFIXED TO PLANS. FAC
 61G15-23.002(2) & FS 471.2055.RESPONSE
 NOTED, BUT IF THE ENGINEER WORKS FOR
 BLYMYER ENGINEERING INC. A CERTIFICATE
 OF AUTHORIZATION IS REQUIRED. IF THE
 ENGINEER DOES NOT WORK FOR BLYMER
 ENGINEERING INC., HE MUST LEGIBLY
 INDICATE HIS ADDRESS ON EACH SHEET.
 **************NEW COMMENTS**************
 1B. SHT P3.1 SANITARY RISER DIAGRAM. A
 FUNNEL FLOOR DRAIN IS NOT AN APPROVED
 INDIRECT WASTE RECEPTOR. PER SECTIONS
 802.3, AND 802.3.2 EITHER A FLOOR SINK
 OR A HUB DRAIN IS REQUIRED.
 2B. SHT P3.1 SANITARY RISER DIAGRAM. THE
 BREAK ROOM SINK SHALL NOT DRAIN THROUGH
 THE HORIZONTAL WET VENT OF THE BATHROOM
 FIXTRUES. THE SINK SHALL DISCHARGE
 DOWNSTREAM OF THE BATHROOM FIXTURES.
 SECTION 909.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-03-25 Cont ID  
Sent By kstevens Date 2005-03-25 Time 09:51 Rev Time 0.00
Received By jwitmer Date 2005-08-07 Time 06:36 Sent To  
Notes
2005-03-25 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
 CITY CODE
  
 1) SHT PRIOR TO SHT C-3, ALL INFORMATION
 DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME
 AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN. SECTION 104.2.1.
 2) ALL ARCHITECTURAL SHEETS, THE PRINTED
 NAME AND CERTIFICATE OF AUTHORIZATION IS
 REQUIRED ON EACH SHEET PER FAC
 61G1-16.004(2) & (6) AND FS 481.219 &
 481.2055.
 3) ALL SHEETS WITH CRAVEN THOMPSON &
 ASSOCIATES, (CIVIL), REQUIRE A
 CERTIFICATE OF AUTHORIZATION NUMBER IN
 THE TITLE BLOCK. FAC 61G15-23.002(2) &
 FS 471.025.
 4) SHT C-10 CALL FOR A SAND/OIL
 INTECEPTOR. THIS SHALL BE SIZED BY
 RONDEY COMPO, ENVIRONMENTAL COMPLIANCE.
 WASTE ORDINANCE 2938-96. CONTACT MR.
 COMPO AT (561) 837-4074 OR E-MAIL
 ADDRESS [email protected].
 5) A DRINKING FOUNTAIN IS REQUIRED PER
 TABLE 403.1.
 6) SHT A5.0 SHEET IS SIGNED/SEALED/DATED
 AS REQUIRED BY FAC 61G1-16.004(5) AND
 FS 481.2055.
 7) SHT A6.0 DETAIL #1 SHOW THE HEIGHT
 11-4.24.2, KNEE CLEARANCE 11-4.24.3,
 SINK DEPTH 11-4.24.4, CLEAR FLOOR SPACE
 11-4.24.5 (FORWARD APPROACH EXTENDING
 MAXIMUM 19" UNDERNEATH THE SINK REQD,
 AND PER THE BUILDING OFFICIAL NO CABINET
 DOORS ALLOWED IN THE CLEAR FLOOR SPACE),
 EXPOSED PIPES AND SURFACES 11-4.24.6,
 AND FAUCETS 11-4.24.7. REQUIRED ON PLANS
 TO SHOW COMPLIANCE.
 8) ALL FS SHEETS, A CERTIFICATE OF
 AUTHORIZATION IS REQUIRED ON THE TITLE
 BLOCK ON EACH SHEET. ALSO THE SEAL AND
 SIGNATURE SHALL BE DATED WHEN SEAL AND
 SIGNATURE ARE AFFIXED TO PLANS. FAC
 61G15-23.002(2) & FS 471.2055.
 9) SUBMIT A SANITARY RISER ISOMETRIC
 THAT REFLECTS THE FLOOR PLAN. SHOW ALL
 PIPE SIZES, REQUIRED TRAPS, VENTS, AND
 CLEANOUTS. SECTION 104.3.1.1.
 10) SUBMIT A WATER RISER ISOMETRIC. SHOW
 ALL PIPE SIZES, VALVES, REQUIRED WATER
 HAMMER ARRESTORS LOCATED NEAR THE
 FIXTURES IN AN "EFFECTIVE RANGE" PER
 PDI-WH 201, REQUIRED BACKFLOWS ECT.
 SECTION 104.2.1.1.
 11) WATER SUPPLY TO THE CAR WASH SHALL
 HAVE AN RPZ BACKFLOW PROTECTION. SECTION
 608.13.2.
 12) SUBMIT A ROOF PLAN SHOWING ALL
 PRIMARY AND SECONDARY ROOF DRAINS.
 INDICATE THE SQUARE FOOTAGE OF THE ROOF
 AND THE SQUARE FOOTAGE DRAINING INTO
 EACH DRAIN. SUBMIT CALCULATIONS FOR
 PRIMARY AND SECONDARY ROOF DRAINS.
 INCLUDE 1/2 AREA OF ALL VERTICAL WALLS
 INCLUDING PARAPETS IN CALCULATIONS.
 SECTIONS 1106 & 1107 AND ALL SUBSECTIONS
 SUBMIT A DETAIL FOR SCUPPERS IF USED FOR
 SECONDARY ROOF DRAINS SHOWING HEIGHT &
 WIDTH. SUBMIT STORM DRAIN ISOMETRIC AND
 STORM RISER DIAGRAMS SHOWING ALL PIPE
 SIZES AND SQUARE FOOTAGE AS IT
 ACCUMULATES IN THE SYSTEM. SECTION
 104.2.1.
 13) PLANS ARE INCOMPLETE AT THIS REVIEW
 AND MORE COMMENTS MAY BE ADD ON THE NEXT
 REVIEW. SECTION 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2005-08-16 Cont ID  
Sent By mmclean Date 2005-08-16 Time 09:25 Rev Time 0.00
Received By mmclean Date 2005-08-16 Time 09:25 Sent To  
Notes
2005-08-16 00:00:00PASS BY GRACE JOYCE PLANNER, 822-1435 MM

Review Stop Z ZONING
Rev No 2 Status F Date 2005-06-20 Cont ID  
Sent By mmclean Date 2005-06-20 Time 15:27 Rev Time 0.00
Received By mmclean Date 2005-06-20 Time 15:27 Sent To  
Notes
2005-06-20 00:00:00DENIED,
 1. LANDSCAPE PLAN DOES NOT MATCH
 SITEPLAN.
 2. THERE IS STILL NO FOUNDATION PLANTING
  
  
 ANY QUESTIONS, PLEASE CALL GRACE JOYCE,
 PLANNER 822-1435

Review Stop Z ZONING
Rev No 1 Status F Date 2005-04-05 Cont ID  
Sent By mmclean Date 2005-04-05 Time 10:48 Rev Time 0.00
Received By mmclean Date 2005-04-05 Time 10:48 Sent To  
Notes
2005-04-05 00:00:00DENIED,
 1. MUST PROVIDE BUILDING FOUNDATION
 PLANTINGS.
 2. MUST PROVIDE (1) HANDICAP SPACE.
 3. MUST PROVIDE STALL STRIPPING FOR
 EMPLOYEE PARKINGS.
 4. MUST PROVIDE A PEDISTRIAN ACCESS FROM
 PUBLIC RIGHT OF WAY.
 ANY QUESTIONS, PLEASE CALL GRACE JOYCE,
 PLANNER 822-1435