Plan Review Stops For Permit 05030554 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-05-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-05-13 |
Time |
15:18 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2005-05-13 |
Time |
15:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-03-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-03-22 |
Time |
10:31 |
Rev Time |
2.00 |
Received By |
shill |
Date |
2005-03-22 |
Time |
10:31 |
Sent To |
|
|
Notes |
2005-03-22 00:00:00 | PERMIT #05030554 | | | | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2.) THE SEAL IS TO BE DATED, FAC61G1-15. | | | | 3.) OCCUPANCY CLASSIFICATIONS OF B AND M | | (STATED AS ?RETAIL?) ARE DECLARED, SHEET | | A.PLEASE READ FBC CHAPTER 3.IF THERE | | ARE TWO OCCUPANCIES, PLEASE SHOW | | OCCUPANCY SEPARATION REQUIRED FBC TABLE | | 704.1. | | | | 4.) SHOW THE MANEUVERING CLEARANCE, PUSH | | SIDE, FOR THE NEW DOCTOR?S OFFICE, NEW | | TREATMENT ROOM #1,EXISTING KITCHEN | | PULL SIDE, ACCESSIBLE BATHROOM PULL | | SIDE, NEW TREATMENT ROOM #3 PUSH AND | | PULL SIDE. | | | | 5.) THE ELEVATION FOR THE TOILET/LAV, P2 | | DOES NOT MATCH THE FLOOR PLAN.NOTE | | MINIMUM DISTANCE FROM CENTERLINE OF | | TOILET TO LAV, FBC11 FIGURE 28. | | | | 6.) ELEVATION, P2 SIDE WALL, SHOW MAX | | DISTANCE FOR GRAB BAR FROM THE BACK | | WALL, FBC11 FIGURE 29. | | | | 7.) NOTE HALLWAY WIDTHS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-08 |
Time |
20:39 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-09-08 |
Time |
20:37 |
Sent To |
|
|
Notes |
2005-09-08 00:00:00 | REDLINED PANEL SCHEDULE AND PLANS FOR | | CIRCUITING. | | PLEASE SEE 26/28 SHOWS A/C UNIT, HOWEVER | | PLANS INDICATES GEN RECEPTS? | | PLEASE SEE CIRCUITING FO REM/EXT LTS PER | | 700.12E, SHALL BE WIRED TO LOCAL | | LIGHTING BRANCH CIRCUIT. | | REDLINED BOTH SETS, PANEL SCHEDULE ON | | PANEL AT FIELD TO BE VERIFIED FOR CODE | | COMPLAINCE AND CORRECT CIRCUITS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2005-09-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-04 |
Time |
11:48 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-09-04 |
Time |
11:46 |
Sent To |
|
|
Notes |
2005-09-04 00:00:00 | ********* UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE PLANS HAVE COME BACK | | IN CONTAINING A RAISED SEAL OVER A | | "PHOTO-COPIED "SIGNATURE FOR THE | | ARCHITECT OF RECORD. PLEASE SEE FS | | 481.221, FAC 61G1-16.003 WHICH STAES THE | | SIGNATURE OF ARCHITECT MUST BE AN | | ORIGINAL SIGNATURE. | | PLEASE SEE ONE COPY OF PLANS SUBMITTED | | IS BEING RETAINEDAND MAY BE SUBMITTED | | FOR POSSIBLE REVIEW BY STATE BOARD OF | | ARCHITECTS. | | | | 2)NOTE: PLEASE RE-CAD PLANS WITH ALL | | INFORMATION AS CHANGED FROM ORIGINAL | | PLANS. PLEASE SEE FBC 104.2.1, WHICH | | REQUIRES PLANS TO BE DONE IN A NEAT A | | DETAILED MANNER FOR LEGIBILITY. | | PLEASE BE SURE ALL CIRCUITING FOR NEW | | DEVICES AND EQUIPMENTIS SHOWN ON PLANS | | AND CORRELATES WITH THE SUBMITTED PANEL | | SCHEDULE. | | PLEASE ALSO REVISE LOAD CALCULATIONS PER | | NEC 220 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2005-08-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-08-18 |
Time |
20:53 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-08-18 |
Time |
20:52 |
Sent To |
|
|
Notes |
2005-08-18 00:00:00 | ********* UNSAT *********** | | | | *** PLEASE SEE COMMENTS FROM PREVIOUS | | "PROVISO" WHICH WAS GIVEN IN JUNE 05. | | | | | | 1)NOTE: PLEASE SEE 240.4,310.16 FOR MIN | | SEC'S/FEEDERS FOR A 200A SERVICE. | | PLEASE SEE 2/0'S ARE NOT RATED FOR | | 200A'S. | | | | 2)NOTE: PLEASE CORRELATE RISER DIAGRAM | | FOR FEEDERS, OCP, CONDUIT ETC FOR X-RAY | | EQUIPMENT. | | 310.16, 240.4, 215.5 | | | | 3)NOTE: PLEASE SEE FS 481.221 AND FAC | | 61G1-16.003 REQUIRES THE SEAL OF | | ARCHITECT TO RAISED, CLEAR AND VISABLE | | WITH ALL INFORMATION AS SET-FORTH ON | | SAID SEAL. | | PLEASE SEE RAISED SEAL IS NOT READABLE. | | PLEASE ALSO SEE FS 481.221 ALSO REQUIRES | | ARCHITECT TO "DATE" PLANS WHEN SIGNING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-06-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-24 |
Time |
10:59 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-06-24 |
Time |
10:54 |
Sent To |
I |
|
Notes |
2005-06-24 00:00:00 | ********** PROVISO/REVISION ********* | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | AND PANEL SCHEDULE FOR NEW X-RAY FEED. | | PLEASE SEE RISER SHOWS 2/0'S AND PANEL | | SCHEDULE SHOWS #4?? | | 215.5 | | | | 2)NOTE: PLEASE SEE UPGRADE FOR SERVICE | | TO 200A'S PER 310.16, RISER SHOWS 2/0'S | | AND 3/0'S ARE REQUIRED. | | | | PLEASE MAKE THE ABOVE CORRECTIONS AND | | SUBMIT REVISION FOR REVIEW AND STAMPING | | BEFORE ROUGH ELECTRICAL INSPECTION. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-26 |
Time |
07:46 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-04-26 |
Time |
07:35 |
Sent To |
|
|
Notes |
2005-04-26 00:00:00 | ****** UNSAT 2ND REVIEW ******** | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | REVIEW STILL NEED TO BE ADDRESSED. | | | | 1)NOTE: NOTE #1 NO, PLEASE SEE RISER | | STILL INDICATED AS EXISTING YET, ALSO | | SHOWS UPGRADE. PLEASE CLARIFY WHAT WORK | | IS BEING DONE TO SERVICE. | | PLEASE SEE MAIN BRKR DISCONNECT IS SHOWN | | FEEDING MLO PANEL AND ALSO SHOWS A TAP ? | | TO NEW 150A DISC? | | 215.5,240.21,240.4,310.16 ETC. | | | | 2)NOTE: NOTE #2 NO, PLEASE SEE PREVIOUS | | NOTES. | | PLEASE SEE NEW NOTES AT BOTTOM. | | | | 3)NOTE: NOTE #3 OK. | | | | 4)NOTE: NOTE #4 NO, PLEASE SEE NO | | CIRCUITING SHOWN FOR NEW? | | PLEASE SEE ONLY NOTE ADDED FOR EM LTS. | | | | NEW NOTES: | | | | 1)NOTE: PLEASE SEE A PANEL SCHEDULE WAS | | NOW SUBMITTED, HOWEVER NO LIGHTING IS | | CIRCUITED ON PLANS? NO LIGHTING IN LOAD | | CALCULATIONS ? | | PLEASE ALSO SEE NO LOAD CALCULATIONS | | WERE DONE FOR SERVICE MAIN, TENANT MAIN | | ETC. | | 215.5 | | | | 2)NOTE: PLEASE SEE NEW 150A MAIN DOES | | NOT MEET 110.26 FOR MIN CLEARENCE AS | | SHOWN ON PLANS. | | | | 3)NOTE: PLEASE SEE COPY OF FS | | 553.80(2)(B) ATTACHED WITH RESPECT TO | | DESIGN PROFESSIONAL. | | THIS IS ONLY A NOTICE GIVEN AT THIS | | TIME. | | | | 4)NOTE: PLEASE SEE ELECTRICAL NOTES | | MENTIONS THE SFBC, WE ARE UNDER THE 2001 | | FBC. | | PLEASE ALSO SEE NOTE WHICH MENTIOSN | | BROWARD COUNTY,,,,, ETC. | | | | PLEASE SEE SOME OF THE ABOVE ITEMS ARE | | REDLINED ON PLANS AT LOCATIONS OF NOTES. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | INSERT ONLY NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-03-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-03-14 |
Time |
08:48 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-03-14 |
Time |
08:48 |
Sent To |
|
|
Notes |
2005-03-14 00:00:00 | ************ UNSAT *************** | | | | 1)NOTE: PLEASE SEE SERVICE NOTE MENTIONS | | | | UPGRADE EXISTING ELECTRICAL RISER. | | PLEASE VERIFY WHAT APPAEARS TO BE A | | "TAP" FROM 200A MAIN DISC WHICH ALREADY | | FEEDS AND EXISTING 200A MLO PANEL. | | 240.21 | | | | 2)NOTE: PLEASE SUBMIT LOAD CALCUALTIONS | | FOR EXISTING 200A DISCONNECT AND FOR | | EXSITNG 1200A MAIN SERVICE. | | 220.3,220.10,220.11,220.13 ETC. | | PLEASE SEE ALL CONTINOUS LOADS TO BE | | SHOWN AT 125%.215.3,230.42 ETC | | 215.5 | | | | 3)NOTE: PLEASE SEE CONDUCTOR SIZE SHOWN | | FROM 150A DISCONNETC. #1? | | PLEASE SEE 310.16 75DEGREE COLUMN FOR | | MIN AWG FOR 150A'S. | | | | 4)NOTE: PLEASE INCLUDE ALL CIRCUITNG ON | | PLANS FOR NEW AND CORRELATE WITH A PANEL | | SCHEDULE TO BE SUBMITTED. | | PLEASE ALSO SEE 700.12E FOR CIRCUITING | | OF ANY EM/EXT LTS WHICH MAY OR MAY NOT | | BE REQUIRED. | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | OTHER REVIEWER(S) WHICH MAY AFFECT | | ELECTRICAL PLANS. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | PLEASE SUBMIT ONE COPY OF OLD SHEETS FOR | | REFERENCE ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2005-07-01 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-07-01 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-07-01 |
Time |
14:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2005-05-04 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-05-04 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-05-04 |
Time |
15:15 |
Sent To |
|
|
Notes |
2005-05-04 00:00:00 | 1) EXITS SHOWN ON DRAWINGS. IT DOESN'T | | SHOW AN ILLUMINATION SOURCE. | | | | 2) EMERGENCY LIGHTING WITH BACK UP | | BATTERY IS REQUIRED WHERE ARTIFICIAL | | LIGHT IS INADEQUATE. | | | | | | MIKE WENNERGREN, A/CAPTAIN | | WPBFR(561) 835-2910 OR 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2005-03-28 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-03-28 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-03-28 |
Time |
14:26 |
Sent To |
|
|
Notes |
2005-03-28 00:00:00 | DENIED | | | | 1) PLEASE BE ADVISED THAT ALL | | CONSTRUCTION, RENOVATION AND DEMOLITION | | SHALL COMPLY WITH NFPA 241. | | | | 2) NO EXIT SIGNS OR EMERGENCY LIGHTING | | CAN BE FOUND ON THE PLANS. PLEASE | | INDICATE HOW THE MEANS OF EGRESS WILL BE | | ACCOMPLISHED. | | | | 3) PLEASE BE ADVISED THAT 2A-10B-C FIRE | | EXTINGUISHERS MUST BE MOUNTED NOT TO | | EXCEED A TRAVEL DISTANCE OF 75 FEET. | | | | 4) PLEASE PROVIDE INFORMATION REGARDING | | THE INTERIOR FINISH CLASSIFICATION OF | | WALLS AND CEILINGS. | | | | 5) SEPARATE SHOP DRAWINGS AND PERMIT | | WILL BE REQUIRED FOR THE FIRE ALARM | | REMODEL IF APPLICABLE. | | | | | | MIKE WENNERGREN, A/CAPTAIN | | WPBFR(561) 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-09-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-02 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-02 |
Time |
11:25 |
Sent To |
E |
|
Notes |
2005-09-02 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-17 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-17 |
Time |
14:57 |
Sent To |
E |
|
Notes |
2005-08-17 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-21 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-21 |
Time |
08:58 |
Sent To |
|
|
Notes |
2005-06-24 00:00:00 | WAITING FOR "COMM" BD | | TO "COMM" BD#30 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-25 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-25 |
Time |
08:32 |
Sent To |
|
|
Notes |
2005-04-25 00:00:00 | TO "COMM" BD#32 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-04-04 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-04-04 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2005-03-11 |
Time |
15:45 |
Sent To |
|
|
Notes |
2005-03-11 00:00:00 | TO "COMM" BD#41 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-05-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-05-31 |
Time |
15:15 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2005-05-31 |
Time |
15:15 |
Sent To |
|
|
Notes |
2005-05-31 00:00:00 | PLANS APPROVED 4-4-05 NO CHANGE |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-04-04 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-04-04 |
Time |
16:12 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2005-04-04 |
Time |
16:04 |
Sent To |
|
|
Notes |
2005-04-04 00:00:00 | DENIED: | | PLANS ARE TO DATED BY THE ARCHITECT AS | | PER FS 481.221 & FAC 61G1-16.004. | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2005-07-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-07-05 |
Time |
07:14 |
Rev Time |
2.00 |
Received By |
kstevens |
Date |
2005-07-01 |
Time |
18:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2005-06-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-06-03 |
Time |
16:22 |
Rev Time |
1.33 |
Received By |
kstevens |
Date |
2005-06-03 |
Time |
16:22 |
Sent To |
|
|
Notes |
2005-06-03 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FLORIDA STATUTES | | | | FROM PREVIOUS REVIEW: | | 2. SHT A2 PROCESSING UNIT MAY REQUIRED A | | NEUTRALIZING TANK. CONTACT RODNEY COMPO, | | ENVIRONMENTAL COMPLIANCE (561) 837-4074, | | OR E-MAIL [email protected]. SUBMIT HIS | | DETERMINATION WORKSHEET WITH PLANS WHEN | | RESUBMITTING PLANS FOR REVIEW. | | 5. SHT P1 WATER RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN, NOR DOES IT MEET | | THE CODE REQUIREMENTS. SECTION 104.2.1. | | B. SHOW REQUIRED WATER HAMMER ARRESTORS | | INSTALLED PER PDI-WH 201 & MANUF. | | INSTALLATION INSTRUCTIONS. | | F. AIR CHAMBERS ARE NOT APPROVED. | | SECTION 604.9. - DELETE FROM RISER. | | 6. SHT P2 THE FOLLOWING INFORMATION FOR | | THE ACCESSIBLE TOILET ROOM SHALL BE | | SHOWN ON THE DETAIL SHT P2 AND THE FLOOR | | PLAN: | | A. CLEAR FLOOR SPACE 11-4.16.2 - W/C | | B. CLEAR FLOOR SPACE 11-4.19.3 - LAV | | 7. ALL DEVICES INTENDED TO SERVE SOME | | SPECIAL FUNCTION SUCH AS PROCESSING, AND | | THAT CONNECT TO THE WATER SUPPLY SYSTEM, | | SHALL BE PROVIDED WITH PROTECTION | | AGAINST BACKFLOW. SECTION 608.3 - PLEASE | | PROVIDE METHOD OF PROTECTION. SECTION | | 104.2.1. - RESPONSE NOTED, BUT PER | | SECTION 608.15.1 OPENINGS AND OUTLETS | | EQUIPPED FOR HOSE CONNECTION SHALL BE | | PROTECTED BY MEANS OTHER THAN AN AIR | | GAP. | | ****************NEW COMMENTS************ | | 1B. SHT P1 SANT. RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN, NOR DOES IT MEET | | CODE REQUIREMENT. | | A. ONLY SHOW FIXTURES THAT WILL BE ON | | THE RISER DIAGRAM. | | B. THE SINK AND PROCESSOR SHALL NOT | | DRAIN THROUGH THE HORIZONTAL WET VENT | | FOR THE BATHROOM FIXTURES. SECTION 909.1 | | SEE RED LINE CORRECTIONS FOR THIS ON THE | | RISER DIAGRAM AND THE FLOOR PLAN. | | C. FIXTURE IS MISLABELED. NEW SINK IN | | DARK ROOM LABELED AS EXISTING LAV. | | D. WASH MACHINE IS NOT VENTED AND A | | CLEANOUT 4' ABOVE THE FLOOR IS REQUIRED | | AT WASH MACHINE. | | 2B. SHT P1 WATER RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN, NOR DOES IT MEET | | CODE REQUIREMENTS. | | A. INDICATE WHERE THE HOT AND COLD | | WATER LINES PAST THE LAST FIXTURES TO | | THE LEFT AND RIGHT ARE CONNECTING TO? | | SECTION 104.2.1. | | B. THE WATER CLOSET IS NOT SHOWN ON THE | | RISER DIAGRAM. | | C. NEW SINK IN DARK ROOM LABELED AS | | EXISTING LAV. | | D. DELETE ALL AIR CHAMBERS, AND SHOW | | WATER HAMMER ARRESTORS AT WASH MACHINE | | AS REQUIRED IN SECTION 604.9. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-03-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-03-23 |
Time |
07:31 |
Rev Time |
2.00 |
Received By |
kstevens |
Date |
2005-03-22 |
Time |
18:55 |
Sent To |
|
|
Notes |
2005-03-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A2 ALTERED PORTIONS OF EXISTING | | BUILDINGS AND FACILITIES REQUIRED TO BE | | ACCESSIBLE BY 11-4.1.6 SHALL COMPLY WITH | | 11-4.1 THROUGH 11-4.35. SECTION | | 11-4.1.1(1)(A).- IF EXISTING ELEMENTS | | , SPACES, OR COMMON AREAS ARE ALTERED, | | THEN EACH SUCH ALTERED ELEMENT, SPACE, | | FEATURE, OR AREA SHALL COMPLY WITH THE | | APPLICABLE PROVISIONS OF 11-4.1.1 TO | | 11-4.1.3 MINIMUM REQUIREMENTS FOR NEW | | CONSTRUCTION. - THE "NEW DARKROOM" HAS A | | WATER CLOSET AND "LAV" IN IT AND IS | | STILL CONSIDERED A TOILET ROOM AND SHALL | | BE ACCESSIBLE. | | 2) SHT A2 PROCESSING UNIT MAY REQUIRE A | | NEUTRALIZING TANK. CONTACT RODNEY COMPO, | | ENVIRONMENTAL COMPLIANCE (561) 837-4074 | | OR E-MAIL [email protected]. SUBMIT HIS | | DETERMINATION WORKSHEET WITH PLANS WHEN | | RESUBMITTING PLANS FOR REVIEW. | | 3) A DRINKING FOUNTAIN IS REQUIRED PER | | TABLE 403.1. | | 4) SHT P1 SANITARY RISER DIAGRAM DOES | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | MEET CODE REQUIREMENTS: SEC 104.2.1. | | A) THE WASH MACHINE IS NOT SHOWN ON THE | | SANT. RISER. | | B) SHOW ALL PIPE SIZES | | C) FLOOR PLANS INDICATES A P-TRAP AND | | STANDPIPE FOR THE PROCESSOR THATS NOT | | SHOWN ON THE RISER DIAGRAM. | | 5) SHT P1 WATER RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN, NOR DOES IT MEET | | THE CODE REQUIREMENTS: SECTION 104.2.1. | | A) SHOW ALL PIPE SIZES | | B) SHOW REQUIRED WATER HAMMER ARRESTORS | | INSTALLED PER PDI-WH 201 & MANUF. | | INSTALLATION INSTRUCTIONS NEAR THE | | FIXTURE IN AN "EFFECTIVE RANGE" NOT IN | | THE CEILING. | | C) FULL OPEN VALVES ARE REQUIRED ON ALL | | WATER DOWN-FEED PIPES. 606.1(4) | | D) IDENTIFY ALL FIXTURES ON THE RISER, | | AND SHOW THE WASH MACHINE AND ALL | | EXISTING FIXTURES. | | E) SHOW ALL REQUIRED VALVES | | F) AIR CHAMBERS ARE NOT APPROVED. | | SECTION 604.9 | | 6) SHT P2 THE FOLLOWING INFORMATION FOR | | THE ACCESSIBLE TOILET ROOM SHALL BE | | SHOWN ON THE DETAIL SHT P2 AND THE FLOOR | | PLAN: | | A) CLEAR FLOOR SPACE 11-4.16.2 - W/C | | B) CLEAR FLOOR SPACE 11-4.19.3 - LAV | | C) EXPOSED PIPES & SURFACES 11-4.19.6 | | D) A 5' TURNING AREA REQUIRED IN EACH | | TOILET ROOM. 11-4.22.3 | | 7) ALL DEVICES INTENDED TO SERVE SOME | | SPECIAL FUNCTION SUCH AS PROCESSING, AND | | THAT CONNECT TO THE WATER SUPPLY SYSTEM, | | SHALL BE PROVIDED WITH PROTECTION | | AGAINST BACKFLOW. SECTION 608.3. - | | PLEASE PROVIDE METHOD OF PROTECTION. | | SECTION 104.2.1. | | 8) PROVIDE DETAIL FOR KITCHEN SINK | | ACCESSIBLITY. SHOW THE FOLLOWING | | INFORMATION: | | A) HEIGHT 11-4.24.2 | | B) KNEE CLEARANCE 11-4.24.3 | | C) SINK DEPTH 11-4.24.4 | | D) CLEAR FLOOR SPACE 11-4.24.5 SHALL BE | | PROVIDED TO ALLOW FORWARD APPROACH, AND | | SHALL EXTEND A MAXIMUM 19" UNDERNEATH | | THE SINK. | | E) EXPOSED PIPES & SURFACES 11-4.24.6 | | F) FAUCETS 11-4.24.7 | | G) SHOW TURNING AREA IN KITCHEN. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|