Plan Review Details - Permit 05030164
Plan Review Stops For Permit 05030164
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-06-03 Cont ID  
Sent By jgomez Date 2005-06-03 Time 18:56 Rev Time 2.00
Received By jgomez Date 2005-06-03 Time 18:56 Sent To Z
Notes
2005-06-03 00:00:00BUILDING REVIEW PROVISO:
 1- CEILING INSTALLATION AT ENTRY PORCH
 TO HAVE 2" MIN. NAIL. (ASTM C-926).
  
 2- PROVIDE PRODUCT APPROVAL REPORT THAT
 MATCHES ONE SUBMITTED FOR FLORIDA
 PRODUCT APPROVAL. BENCHMARK MODEL IS NOT
 INCLUDED IN THE APPROVED PACKAGE.
  
 3- NEED FLORIDA/LOCAL PRODUCT APPROVAL
 FOR TRUSS CONNECTORS SPECIFIED ON PLANS.
  
 4- NEED ANOTHER DADE COUNTY NOA FOR
 SINGLE HUNG WINDOWS. ONE SUBMITTED THE
 FILE IS CLOSED.
  
 5- SPECIFY STRAPS TO BE USED AT ENTRY
 COLUMN ROOF TRUSS. SEC. 104.2.1.2 CITY
 AMENDEMNTS TO FBC 2001.
  
 NOTE: PROVIDE ALL INFORMATION PRIOR TO
 INSTALLATION OR CONSTRUCTION TO AVOID
 DELAYS OR CONFLICTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-03-18 Cont ID  
Sent By jgomez Date 2005-03-18 Time 16:37 Rev Time 2.00
Received By jgomez Date 2005-03-18 Time 16:37 Sent To PC
Notes
2005-03-18 00:00:00BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- IMPACT FEES RECEIPT SHOWS A BALANCE
 DUE. PAY BALANCE AND BRING BACK COPY OF
 RECEIPT PAID IN FULL.
  
 3- ENGINEER NEEDS TO HAVE ALL HIS
 INFORMATION AS REQUIRED BY CHAPTER 471
 FL.STATUTES. ALSO, SEE ADMINISTRATIVE
 CODE SECTION 61G15-23.002 FOR
 INFORMATION REQUIRED BY ENGINEER.
  
 4- NEED TO PROVIDE 2 SETS OF PLANS AND
 ALL REQUIRED INFORMATION.
  
 5- SPECIFY 30PSF OR 10PSF ATTIC LIVE
 LOAD AS REQ'D BY TABLE 1604.1 FBC 2001.
  
 6- SPECIFY WHAT'S THE USE OF THE ROOM
 ADJACENT TO THE KITCHEN.
  
 7- REVISE TYPICAL WALL SECTION TO SHOW
 FOOTING TO BE 12" MIN. BELOW GRADE (SEC.
 1804.1.3 FBC 2001) AND CONCRETE SLAB TO
 BE MIN. 4" ABOVE FINISH GRADE AS REQ'D
 BY SEC. 1804.1.7 CITY AMENDMENTS TO FBC.
  
 8- PROVIDE SOIL TEST REPORT.
  
 9- CLARIFY FOOTING REINFORCEMENT. TYP.
 WALL SECTION CALLS FOR 3#5, WHILE
 FOUNDATION PLAN CALLS FOR 2#5. REVISE.
  
 10- SPECIFY CEILING INSTALLATION AT
 ENTRY PORCH. SPECIFY FASTENERS SIZE AND
 SPACING. SEE ASTM C926 AND ASTM C1063.
 SEC. 2504.2 FBC 2001.
  
 11- PROVIDE CLEAR TRUSS ANCHOR SCHEDULE.
 SEC. 104.2.1.2 CITY AMENDMETNS TO FBC
 2001. (SEE LATEST SIMPSON CATALOGUE AND
 PROVIDE ENGINEERING FOR TYPE AND NUMBER
 OF FASTENERS THAT DIFFER FROM
 CATALOGUE). SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 12- TRUSS NOTES ON SHEET A-3 AND TYP
 WALL SECTION DON'T MATCH. SEE TYPE AND
 NUMBER OF FASTENERS SPECIFIED AND REVISE
 AS REQUIRED.
 **NOTE: SEE LATEST SIMPSON CATALOGUE FOR
 NUMBER OF FASTENERS TO BE USED.
 FASTENERS WERE REVISED TO COMPLY WITH
 SEC. 1609.4.3 FBC 2001 WERE THE STEEL
 STRESS COULD NOT BE INCREASED.
 OTHERWISE, ENGINEER TO PROVIDE
 ENGINEERING CALCULATIONS (SEE SEC.
 1609.4.3 FBC 2001)FOR NUMBER OF
 FASTENERS THAT DIFFER FROM THOSE TESTED
 AND PUBLISHED BY MANUFACTURER.
  
 13- LINTEL SCHEDULE DON'T MATCH PLAN.
 REVISE AS REQUIRED.
  
 14- ENERGY CALCULATIONS: A) OWNER/AGENT
 TO SIGN AND DATE BOTTOM OF FORM.
 B) COMPLETE INFORMATION ON TOP OF FORM.
 INCLUDING BUILDING ADDRESS.
  
 15- STORM SHUTTERS: A) PROVIDE FLORIDA
 OR LOCAL PRODUCT APPROVAL.
 B) PROVIDE KEY PLAN AND COMPLETE
 INSTALLATION SCHEDULE. SEE SAMPLE.
 C) CLEARLY MARK ON SHUTTER DRAWINGS
 SPECIFIC MOUNTING CONDITIONS AND ANCHOR
 TYPE AND SPACING TO BE USED ACCORDING TO
 THE DESIGN PRESSURES, EDGE DISTANCE,
 PANEL SPAN, CONNECTION TYPE AND
 STRUCTURE TO BE ATTACHED TO (MASONRY OR
 CONCRETE).
  
 16- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR: (NOTE: DADE COUNTY PRODUCT
 APPROVAL IS NOT A FLORIDA PRODUCT
 APPROVAL)
 A) WINDOW MULLIONS.
 B) SLIDING GLASS DOORS AND CLEARLY
 IDENTIFY SIZE OF SILL TO BE USED
 ACCORDING TO THE DESIGN PRESSURES.
 C) GARAGE DOOR FOR SIZE OF DOOR USED.
 D) ROOF SHINGLES.
 E) ENTRY DOOR.NOTE: INSWING AS SHOWN
 ON PLANS.
 F) SIMPSON TRUSS CONNECTOR USED.
 G) SINGLE HUNG WINDOWS.
  
 17- DESIGN PRESSURES SPECIFIED FOR
 GARAGE DOOR ARE TOO LOW. PROVIDE
 ENGINERING CALCULATIONS SHOWING HOW THE
 DESIGN PRESSURES WERE DETERMINED. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 18- OWES $116.20 FOR LOW VALUATION AND
 RADON FEES.
  
 19- CLARIFY R VALUE FOR INSULATION AT
 ATTIC. ENERGY CALCS CALLS FOR R-19,
 WHILE TYP. WALL SECTION CALLS FOR R-30.
 REVISE AS REQUIRED.
  
 20- SHEET A-3: A) CLARIFY FASTENER FOR
 GARAGE DOOR BUCK. NOTES ON SHEET A-1 AND
 NOTES ON DETAIL DON'T MATCH. REVISE.
 B) CLARIFY CONNECTORS SPECIFIED FOR
 ENTRY PORCH BEAM. WHAT'S HUS210-3? SEE
 SIMPSON CATALOGUE.
 C) SPECIFY THE 4 STRAPS SPECIFIED FOR
 ENTRY PORCH ON TOP OF CONCRETE COLUMN.
 NOTE: NEED WOOD TO MASONRY CONNECTOR.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 D) ROOF FRAMING PLAN IS MISSING LINTEL
 AT ROOM ADJACENT TO KITCHEN.
 SEE COMMENTS ON PLANS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop DEMO DEMO/BOARD/SEC/EMERGENCY
Rev No 1 Status N Date 2005-06-06 Cont ID  
Sent By btrobaug Date 2005-06-06 Time 11:01 Rev Time  
Received By btrobaug Date   Time   Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-06-06 Cont ID  
Sent By btrobaug Date 2005-06-06 Time 11:02 Rev Time 0.50
Received By btrobaug Date 2005-06-06 Time 11:02 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-03-14 Cont ID  
Sent By btrobaug Date 2005-03-14 Time 12:44 Rev Time 1.00
Received By btrobaug Date 2005-03-11 Time 11:50 Sent To M
Notes
2005-03-14 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} CALCULATE AND SUBMIT THE AVAILABLE
 FAULT CURRENT AND INDICATE AIC RATING
 FOR THE SERVICE EQUIPMENT PER 110.9 &
 10.
  
 2} THE RISER DIAGRAM IS TO VAGUE.
 INDICATE WHAT IS TO BE INSTALLED ON THE
 PLAN. REMOVE ALL "OPTIONS" AND "IF
 REQUIRED" LANGUAGE. IF UNCERTAIN
 COORDINATE WITH ELECTRICAL CONTRACTOR.
  
 3} INDICATE THE LOCATION OF ALL SERVICE
 EQUIPMENT ON THE PLAN PER 110.26, 215.5
 AND 230.70 CWBP AMMENDMENTS.
  
 4} INDICATE ALL COMPONENTS OF THE
 GROUNDING ELECTRODE SYSTEM PER 250.50.
  
 5} CORRELATE THE MECHANICAL SPECS AND
 ELECTRICAL PANEL FOR EQUIPMENT SIZE. SEE
 AHU HEATER SIZE.
  
 6} INDICATE COMPLIANCE OF 210.12 AFCI
 FOR SLEEPING ROOMS ON PANEL SCHEDULE.
  
 7} THE ENGINEER OF RECORD MUST PROVIDE A
 TITLE BLOCK ON THE PLANS PER FAC
 61G15-23.002.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-12-14 Cont ID  
Sent By adarroug Date 2005-12-14 Time 13:55 Rev Time 0.00
Received By adarroug Date 2005-12-14 Time 13:55 Sent To P
Notes
2005-12-14 00:00:00TO "P" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-11-23 Cont ID  
Sent By adarroug Date 2005-11-23 Time 14:54 Rev Time 0.00
Received By adarroug Date 2005-11-23 Time 14:54 Sent To M
Notes
2005-11-23 00:00:00TO "M" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-05-13 Cont ID  
Sent By adarroug Date 2005-05-13 Time 16:51 Rev Time 0.00
Received By adarroug Date 2005-05-13 Time 16:51 Sent To E
Notes
2005-05-13 00:00:00TO "BTROBAUG"DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-11 Cont ID  
Sent By adarroug Date 2005-03-11 Time 10:12 Rev Time 0.00
Received By adarroug Date 2005-03-11 Time 10:12 Sent To E
Notes
2005-03-11 00:00:00TO SFR "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-03-18 Cont ID  
Sent By jgomez Date 2005-03-18 Time 18:27 Rev Time 0.00
Received By jgomez Date 2005-03-08 Time 08:41 Sent To PC
Notes
2005-03-08 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-11-28 Cont ID  
Sent By tgordon Date 2005-11-28 Time 13:33 Rev Time 0.30
Received By tgordon Date 2005-11-28 Time 13:33 Sent To  
Notes
2005-11-28 00:00:00REV. TO MECH. PLANS AND E-CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-08-31 Cont ID  
Sent By hmoser Date 2005-08-31 Time 10:57 Rev Time 0.00
Received By hmoser Date 2005-08-31 Time 10:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-03-14 Cont ID  
Sent By hmoser Date 2005-03-14 Time   Rev Time 0.00
Received By hmoser Date 2005-03-14 Time 15:54 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-05-28 Cont ID  
Sent By btrobaug Date 2005-06-06 Time 11:01 Rev Time 0.51
Received By kstevens Date 2005-05-28 Time 10:45 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-03-18 Cont ID  
Sent By gsalfeld Date 2005-03-18 Time 09:14 Rev Time 1.00
Received By gsalfeld Date 2005-03-18 Time 09:13 Sent To B
Notes
2005-03-18 00:00:001- SHEET A-2 SAN. RISER DIAGRAM DOES NOT
 REFLECT FLOOR PLAN.SHOW ALL PIPE SIZES.
 SEE EXAMPLE:
 2- TITLE BLOCK FOR ENG.MISSING ON ALL
 SHEETS. 61G1-15-23.002 AND FS471.025
 3- ONE SET OF PLANS BEING RETAINED FOR
 POSSIBLE REVIEW BY D.B.P.R.
 4- PLUMBING TO TIE INTO SANITARY
 PROVIDED BY CITY OF WPB.SEPTIC TANKS NOT
 APPROVED.UTILITY ORD.

Review Stop Z ZONING
Rev No 2 Status P Date 2005-06-09 Cont ID  
Sent By mmclean Date 2005-06-09 Time 08:44 Rev Time 0.00
Received By mmclean Date 2005-06-09 Time 08:44 Sent To  
Notes
2005-06-09 00:00:00RE-STAMP PLANS.

Review Stop Z ZONING
Rev No 1 Status P Date 2005-03-10 Cont ID  
Sent By mmclean Date 2005-03-10 Time 16:49 Rev Time 0.00
Received By mmclean Date 2005-03-10 Time 16:49 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved