Plan Review Details - Permit 05030158
Plan Review Stops For Permit 05030158
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-05-06 Cont ID  
Sent By alange Date 2005-05-06 Time 10:25 Rev Time 0.66
Received By alange Date 2005-05-06 Time 10:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-05-02 Cont ID  
Sent By alange Date 2005-05-02 Time 11:42 Rev Time 0.50
Received By alange Date 2005-05-02 Time 11:42 Sent To  
Notes
2005-05-02 00:00:00 
 DENIED
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.PRODUCT APPROVALS WITH QUALITY
 ASSURANCE REQUIRED FOR THE FOLLOWING.
 IMPACT PROTECTION AND STRAPS AND
 TIE-DOWNS.
 ALL PRODUCT APPROVALS REQUIRE THE
 FOLLOWING TO BE ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-03-23 Cont ID  
Sent By alange Date 2005-03-23 Time 09:16 Rev Time 1.00
Received By alange Date 2005-03-23 Time 09:06 Sent To  
Notes
2005-03-23 00:00:00 
 DENIED
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.PRODUCT APPROVALS WITH QUALITY
 ASSURANCE REQUIRED FOR THE FOLLOWING.
 EXTERIOR DOORS, WINDOWS, IMPACT
 PROTECTION AND STRAPS AND TIE-DOWNS.
 ALL PRODUCT APPROVALS REQUIRE THE
 FOLLOWING TO BE ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4.SHOW HOW SMOKE DETECTORS WILL COMPLY
 WITH FBC 905.2
  
 5. PLEASE SHOW ELEVATIONS.A/2 #2 SHOWS
 CHANGE IN ELEVATION.MINIMUM FINISH
 FLOOR HEIGHT ABOVE GRADE IN HABITABLE
 AREAS IS 4" WPB AMMENDMENTS TO THE FBC
 1804.1.7
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2005-05-06 Cont ID  
Sent By btrobaug Date 2005-05-06 Time 09:49 Rev Time 0.00
Received By btrobaug Date 2005-05-06 Time 09:00 Sent To  
Notes
2005-05-06 00:00:00 
 ROUTED TO ELECTRICAL IN ERROR./WRT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-04-18 Cont ID  
Sent By dpalmer Date 2005-04-18 Time 11:37 Rev Time 0.30
Received By dpalmer Date 2005-04-18 Time 11:36 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-05-06 Cont ID  
Sent By dpalmer Date 2005-03-15 Time 12:29 Rev Time 0.66
Received By alange Date 2005-05-06 Time 10:25 Sent To P
Notes
2005-03-15 00:00:00******** UNSAT *********
  
 1)NOTE: PLEASE SEE MISSING SD'S REQUIRED
 INSIDE AND OUTSIDE BEDRM.
 NFPA-72 8-1.4.1.6.2
  
 2)NOTE: PLEASE SHOW ALL RECEPTS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210.8A-6
 SHOWN ON PLANS AS NEW?
  
 3)NOTE: PLEASE SEE 210.12 2002 NEC FOR
 REQUIRED ARC FAULT PROTECTION IN
 BEDROOMS.
 SD'S, LTS, FANS, RECEPTS ETC ARE ALL TO
 BE AFCI PROTECTED.
  
 4)NOTE: PLEASE SEE 220.31B FOR LOAD
 CALCUALTIONS FOR EXSITNG SERVICES.
 PLEASE VERIFY BOTH LOAD CALCULATIONS
 SHOWN. EXISTING AND NEW?
 PLEASE SEE WHAT APPEARS TO BE REVISED
 "NEW" LOAD CALCULATIONS INDICATES ONLY
 ONE AHU? PLANS APPEAR TO NOTE THAT THERE
 MAY BE MORE THAN ONE
 NOTE FOR LOAD CALCULATIONS MENTIONS ONLY
 LOAD ADDED AS 2.3 AMPS, HOWEVER LOAD
 CALCUALTIONS DO NOT CORRELATE WITH THIS.
  
 5)NOTE: PLEASE SEE RECEPTS AT OUTSIDE
 LOCATIONS TO BE SHOWN AS GFI, 210.8.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-05-03 Cont ID  
Sent By adarroug Date 2005-05-03 Time 17:27 Rev Time 0.00
Received By adarroug Date 2005-05-03 Time 17:27 Sent To B
Notes
2005-05-03 00:00:00TO "ALANGE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-04-12 Cont ID  
Sent By adarroug Date 2005-04-12 Time 17:19 Rev Time 0.00
Received By adarroug Date 2005-04-12 Time 17:19 Sent To E
Notes
2005-04-12 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-11 Cont ID  
Sent By adarroug Date 2005-03-11 Time 10:08 Rev Time 0.00
Received By adarroug Date 2005-03-11 Time 10:08 Sent To E
Notes
2005-03-11 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-03-07 Cont ID  
Sent By adarroug Date 2005-03-23 Time 09:24 Rev Time 0.00
Received By alange Date 2005-03-07 Time 11:16 Sent To Z
Notes
2005-03-07 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-03-17 Cont ID  
Sent By pkrauss Date 2005-03-17 Time 12:43 Rev Time 0.20
Received By pkrauss Date 2005-03-17 Time 12:38 Sent To B
Notes
2005-03-17 00:00:00NO MECHANICAL PLANS OR CONTRACTOR
 INDICATED WITH PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-03-16 Cont ID  
Sent By alange Date 2005-05-06 Time 10:25 Rev Time 0.50
Received By gsalfeld Date 2005-03-16 Time 15:41 Sent To M
Notes
2005-03-16 00:00:00NO PLUMBING PLAN SUBMITED,PLUMBING
 PERMIT REQUIRED TO RELOCATE FIXTURES

Review Stop Z ZONING
Rev No 1 Status N Date 2005-03-10 Cont ID  
Sent By mmclean Date 2005-03-10 Time 16:32 Rev Time 0.00
Received By mmclean Date 2005-03-10 Time 16:32 Sent To I
Notes
2005-03-10 00:00:00FOOT PRINT OF HOUSE DOES NOT CHANGE.