Plan Review Details - Permit 05020882
Plan Review Stops For Permit 05020882
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-07-07 Cont ID  
Sent By lsmith Date 2005-07-07 Time 16:29 Rev Time 0.75
Received By lsmith Date 2005-07-07 Time 16:29 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-05-23 Cont ID  
Sent By lsmith Date 2005-05-23 Time 08:17 Rev Time 0.75
Received By lsmith Date 2005-05-23 Time 08:17 Sent To  
Notes
2005-05-23 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. SUBMIT THE MFGR. CUT SHEET ON HEATER
 MODEL.
  
 2. SEE NOTES FROM OTHER REVIEWERS
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-04-05 Cont ID  
Sent By lsmith Date 2005-04-05 Time 15:03 Rev Time 0.50
Received By lsmith Date 2005-04-05 Time 15:03 Sent To  
Notes
2005-04-05 00:00:00BUILDING PLAN REVIEW:FAILED
  
 2 DIFFERENT SETS OF PLANS SUBMITTED.
 CONTRACTOR TO RESUBMIT.
 SEE ZONING, ELEC & PLUMBING COMMENTS

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-07-01 Cont ID  
Sent By jleahy Date 2005-07-01 Time 08:45 Rev Time 0.30
Received By jleahy Date 2005-07-01 Time 08:44 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-05-23 Cont ID  
Sent By btrobaug Date 2005-05-23 Time 11:03 Rev Time 0.33
Received By btrobaug Date 2005-05-23 Time 10:46 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-03-03 Cont ID  
Sent By btrobaug Date 2005-03-03 Time 16:10 Rev Time 0.33
Received By btrobaug Date 2005-03-03 Time 15:44 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-06-21 Cont ID  
Sent By adarroug Date 2005-06-21 Time 13:45 Rev Time 0.00
Received By adarroug Date 2005-06-21 Time 13:45 Sent To P
Notes
2005-06-21 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-05-04 Cont ID  
Sent By adarroug Date 2005-05-04 Time 11:48 Rev Time 0.00
Received By adarroug Date 2005-05-04 Time 11:48 Sent To P
Notes
2005-05-04 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-04-28 Cont ID  
Sent By adarroug Date 2005-04-28 Time 11:07 Rev Time 0.00
Received By adarroug Date 2005-04-28 Time 11:07 Sent To Z
Notes
2005-04-28 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-02 Cont ID  
Sent By adarroug Date 2005-03-02 Time 13:21 Rev Time 0.00
Received By adarroug Date 2005-03-02 Time 13:21 Sent To E
Notes
2005-03-02 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-02-22 Cont ID  
Sent By adarroug Date 2005-02-22 Time 13:26 Rev Time 0.00
Received By adarroug Date 2005-02-22 Time 13:26 Sent To Z
Notes
2005-02-22 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-06-30 Cont ID  
Sent By jleech Date 2005-06-30 Time 14:46 Rev Time 0.75
Received By jleech Date 2005-06-30 Time 14:46 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2005-05-21 Cont ID  
Sent By pschmitz Date 2005-05-21 Time 08:16 Rev Time 0.00
Received By pschmitz Date 2005-05-21 Time 08:16 Sent To B
Notes
2005-05-21 00:00:00PLUMBING PLANN REVIEW FBC 2001 FAILED,
 THIRD TIME.
 (1) PREVIOUS NOTES DATED 3-7-05 G S,
 3-15-05 K S, NOT ADDRESSED.
 (2)SEC 104.2 DRAWINGS & SPECIFICATIONS:
 PROVIDE SUFFICENT INFORMATION, FOR
 CLARITY OF WORK.
 (3) 424.2.6.6.4 MAIN DRAIN: COMMON LINE
 TO PUMP WATER TO DRAIN SIMULTANEUOSLY.
 (4) 424.2.12 TEST: 35 PSI, NO AIR TEST.
 (5) 424.2.13.2 JOINTS, CONNECTIONS: FBCP
 2001 SEC 605.21 PURPLE PRIMER PVC PIPE.
 (6) 424.2.6.2 LIST REQUIRED EQUIPMENT:
 (7) 424.2.7.3 PUMP CAPACITY:HP,GPM.
 (8)424.2.6.3 WATER VELOCITY: FPS.
 (9) ALL OF THE ABOVE TO BE ON PLANS, IN
 NOTES OR SPECIFIC COMMENTS.
 (10) SEE ATTACHED SHEET CONCERNING THE
 DESIGN PROFESSIONAL AND FS 533.80(2)(B)
 IF PLANS COME IN WITH THE SAME COMMENTS
 MORE THAN TWO TIMES 4X FEE WILL BE
 ATTACHED TO PLANS.
 QUESTIONS CONTACT,
 561-805-6692 PAUL SCHMITZ

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-03-15 Cont ID  
Sent By kstevens Date 2005-03-15 Time 18:44 Rev Time 0.50
Received By kstevens Date 2005-03-15 Time 18:44 Sent To B
Notes
2005-03-15 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) PLANS HAVE 2 POOL LAYOUTS AND 2
 ENGINEERS OF RECORD. SHE 2 OF 3 SHOWS 4
 POOL RETURNS, 2 WALL MAIN DRAINS AND 2
 FLOOR MAIN DRAINS. SHT 1 OF 1 SHOWS NO
 POOL RETURNS, AND ALL MAIN DRAINS ON THE
 WALLS. PLEASE CLARIFY. SECTION 104.2.1.
 2) ALL SHEETS BY GATOR ENGINEERING,
 ENGINEER SHALL INDICATE THEIR NAME,
 ADDRESS, AND LICENSE NUMBER ON EACH
 SHEET. ENGINEERS PRINTED NAME AND
 LICENSE NUMBER ARE MISSING. FAC
 61G14-23.002(2) & FS 471.025
 3) SHT 1 OF 1 PIPING DIAGRAM DOES NOT
 SHOW THE VENTS FOR THE MAIN DRAINS, NOR
 DOES IT SHOW A RETURN TO THE POOL FROM
 THE RECIRCULATION PUMB. SECTION 104.2.1.
 4) PLANS BY GATOR ENGINEERING INDICATE
 NO POOL HEATER, BUT PLANS BY BEA
 ENGINEERING SHOW A POOL HEATER ON THE
 PIPING DIAGRAM, PLEASE CLARIFY. SECTION
 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-03-07 Cont ID  
Sent By gsalfeld Date 2005-03-07 Time 11:27 Rev Time 1.00
Received By gsalfeld Date 2005-03-07 Time 11:27 Sent To B
Notes
2005-03-07 00:00:003/7/05
  
 1-PER DUAL MAIN DRAIN ATMOSPHERIC VENT
 ARRANGMENT SH 3.MAIN DRAIN SHALL REFLECT
 VENT ARRANGEMENT.MAIN DRAIN SHALL DRAIN
 SIMULTANEOUSLY.SUCTION LINE SHALL TIE IN
  
 AT CENTER OF THE DRAINS.VENT LINETO TIE
 INTO SUCTION LINE 12" FROM DRAIN TIE IN,
 PER VENT ARRANGEMENT.
 2-SPA LAYOUTS ON SHEETS 1-2 INDICATE
 MAIN DRAINS ON FLOOR.SPA PLAN ON SHEET
 1 OF 1 INDICATE MAIN DRAINS ON WALL.
 PLEASE CORRELATE PLANS.
 3-PIPING DIAGRAM SHEET 1 OF 1 DOES NOT
 SHOW A RETURN LINE FROM 2ND PUMP,PLEASE
 CLARIFY.

Review Stop Z ZONING
Rev No 3 Status P Date 2005-07-18 Cont ID  
Sent By mmclean Date 2005-07-18 Time 12:58 Rev Time 0.00
Received By mmclean Date 2005-07-18 Time 12:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2005-05-03 Cont ID  
Sent By mmclean Date 2005-05-03 Time 18:21 Rev Time 0.00
Received By mmclean Date 2005-05-03 Time 18:21 Sent To I
Notes
2005-05-03 00:00:00DENIED.
 1. SURVEY/SITEPLAN MISSING.MUST
 PROVIDE TWO COPY OF SITEPLAN/SURVEY
 SHOWING THE LOCATION OF
 POOL/SPA/DECK/SCREEN ENCLOSURE WITH
 SETBACKS.
 2. SETBACK FOR CORNER LOT MUST BE 15FT.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-02-23 Cont ID  
Sent By mmclean Date 2005-02-23 Time 12:30 Rev Time 0.00
Received By mmclean Date 2005-02-23 Time 12:30 Sent To I
Notes
2005-02-23 00:00:00DENIED,
 1. SETBACK FOR CORNER LOT
 (SPA/POOL/DECK) IS 15FT.PLANS SHOWS
 SPA AT 6'9".CALLED CONTR LEFT MSG ON
 VOICE MAIL.