Plan Review Stops For Permit 05020312 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2005-03-29 |
Time |
10:49 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2005-03-29 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-02-22 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2005-02-22 |
Time |
09:24 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2005-02-22 |
Time |
09:24 |
Sent To |
|
|
Notes |
2005-02-22 00:00:00 | BUILDING PLAN REVIEW: FAILED: | | | | 1. NOTICE OF COMMENCEMENT SHOWS MICHAEL | | STAIRS AS OWNER, APPLICATION, PBC PAPA & | | CITY SYSTEM SHOWS SWSLLC. | | | | 2. WHERE IS ROTTED FLOOR? WHAT TYPE OF | | FLOOR IS GOING TO BE INSTALLED? HAVE | | FLOOR BEAMS BEEN INSPECTED? | | | | 3. APPLICATION HAS FENCE CHECKED & A | | SURVEY HAS BEEN SUBMITTED WITH PERIMETER | | HIGHLIGHTED. FENCE PERMIT NEEDS EASEMENT | | RELEASE FORM & A SEPARATE PERMIT. | | | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-08-18 |
Time |
12:54 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-08-18 |
Time |
09:42 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-08-03 |
Time |
10:15 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-08-03 |
Time |
10:04 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2005-03-29 |
Time |
10:07 |
Rev Time |
0.45 |
Received By |
jleahy |
Date |
2005-03-29 |
Time |
10:07 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-02-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-02-18 |
Time |
10:25 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-02-18 |
Time |
09:59 |
Sent To |
B |
|
Notes |
2005-02-18 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE APPLICATION INDICATES "ELECTRICAL | | UPGRADE TO CODE". DOES THIS INCLUDE A | | SERVICE UPGRADE? IF SO PROVIDE A RISER | | DIAGRAM PER 215.5. | | | | 2} PLEASE PROVIDE A PANEL SCHEDULE SO | | THAT BRANCH CIRCUIT RATINGS CAN BE | | REVIEWED. | | | | 3} PLEASE SHOW RECEPTACLE LOCATIONS FOR | | THE MASTER BEDROOM. | | | | 4} PLEASE INDICATE SERVICE EQUIPMENT | | SIZE RATING AND LOCATION. | | | | 5} PLEASE NOTE THAT A PERMIT FOR LOW | | VOLTAGE IS REQUIRED. | | THERE IS NONE SHOWN ON THE PLAN, IF | | VALUE AND DRAWINGS SHOWING LOCATIONS ARE | | NOT PROVIDEED ON THIS DRAWING THEY WILL | | BE REQUIRED SEPARATELY, AND MUST BE | | INSPECTED SEPARATELY. | | | | 6} THE PLANS MUST BEAR THE PRINTED NAME | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | FOR THE PLAN PER 104.2.1 FBC. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-18 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-18 |
Time |
09:04 |
Sent To |
E |
|
Notes |
2006-08-18 00:00:00 | TO "BTROBAUG" DESK/RESTAMP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-07-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-27 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-27 |
Time |
13:36 |
Sent To |
E |
|
Notes |
2005-07-27 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-03-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-24 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-24 |
Time |
10:22 |
Sent To |
E |
|
Notes |
2005-03-24 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-02-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-11 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-11 |
Time |
15:53 |
Sent To |
E |
|
Notes |
2005-02-11 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-02-07 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-02-11 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-07 |
Time |
12:55 |
Sent To |
Z |
|
Notes |
2005-02-07 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2005-02-11 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-02-11 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-02-11 |
Time |
13:34 |
Sent To |
I |
|
Notes |
2005-02-11 00:00:00 | ALL WORK IS INTERIOR.SURVEY SHOWS | | HIGHTLIGHTED AREA, NEEDS MORE | | CLARIFICATION. |
|
|