Plan Review Details - Permit 05011202
Plan Review Stops For Permit 05011202
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-04-28 Cont ID  
Sent By jwitmer Date 2005-04-28 Time 07:53 Rev Time 1.10
Received By jwitmer Date 2005-04-28 Time 07:53 Sent To PC
Notes
2005-04-28 00:00:00BUILDING PROVISO: ASEPERATE PERMIT IS
 REQUIRED FOR STORM SHUTTERS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-04-28 Cont ID  
Sent By jwitmer Date 2005-04-28 Time 07:53 Rev Time 1.10
Received By jwitmer Date 2005-04-28 Time 07:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-04-28 Cont ID  
Sent By jwitmer Date 2005-04-25 Time 08:43 Rev Time 1.10
Received By jwitmer Date 2005-04-28 Time 07:51 Sent To PC
Notes
2005-04-28 00:00:00BUILDING PROVISO: A SEPERATE PERMIT IS
 REQUIRED FOR STORM SHUTTERSJW
2005-04-25 00:00:004-25-05 CALLED CONT TO PICK UP PLANS,
 NEED EITHER A SURVEY INDICATING A EGRESS
 EASEMENT OR IN THE COVENENT OF THE PUD
 THAT WAS RECORDED SAID LANGUAGE OF A
 EGRESS EASEMENT.
  
 NO REVIEW COMPLEETED UNTIL DOCUMENT HAS
 BEEN RECEIVED.
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-08 Cont ID  
Sent By jwitmer Date 2005-02-08 Time 08:38 Rev Time 3.33
Received By jwitmer Date 2005-02-08 Time 08:15 Sent To PC
Notes
2005-02-08 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05011202
 ADD: 6450 SPARROW HAWK DRIVE
 CONT: RIF GROUP
 TEL: (561)239-5790
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 FL S S 481.219(2)(3) THE HEADER STRIP
 FOR THE ARCHITECT FIRM JEFFERY
 SILBERSTEIN ARCHITECT & ASSOCIATES,
 INC.
 DOES NOT HAVE THE FIRMS CERTIFICATE OF
 AUTHORIZATION IN THE HEADERSTRIP.
  
 2) SHEET A-2.0 MASTER BEDROOM EGRESS
 WINDOW# 10 IS A FIXED GLASS PANEL. THE
 ADJOINING WINDOW# 3 MEETS THE EGRESS
 REQUIREMENTS, CORRECT.
  
 3) SHEET A-2.0 ALSO INDICATES A DEN ON
 THE ZERO LOTLINE SIDE OF THE HOUSE,
 THERE IS ALSO A ATRIUM AND EXTERIOR
 DOORWAY, THE DEN CANBE USED FOR A
 SLEEPING ROOM REQUIRING A SECOND MEANS
 OF EGRESS THROUGH THE ATRIUM, NOTHING ON
 THE SURVEY INDICATES A ANY ACCESS/EGRESS
 EASEMENTS ON THE ZEERO LOT LINE SIDE OF
 THE HOUSE. THE ELECTRICAL PLAN ALSO
 INDICATES SMOKE DETECTORS AND ARK FAULT
 CIRCUIT BREAKERS WHICH ARE REQUIRED FOR
  
 BEDROOMS OR SLEEPING ROOMS.
 IF NOT USSED AS A SLEEPING ROOM THE
 SURVEY DOESN'T INDICATE A ACCESS
 EASEMENT FOR MAINTENCE OF THE ATRIUM, IN
 EITHER CASE A ACCESS/EGRESS EASEMENT
 SHALL BE REQUIRED.
  
 4)ONLY ONE SOILS REPORT SIGNED AND
 SEALED THE SECOND IS A COPY,
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 5) THE PRODUCT SUBMITTALS FOR WINDOWS
 AND GLAZED DOORS INDICATES "NO LARGE
 MISSLE TESTING". FL BLD CODE
 1606.1.5: COMPONENTS & CLADDING, PROVIDE
 2 COPIES(3 IF THRESH- OLD OR RESIDENT
 INSPECTOR) OF PRODUCT TESTING
 REPORTS,MISSING REPORTS ARE AS FOLLOWS:
 A) STORM SHUTTERS
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.FBC
 1606.1.4.
  
 6)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.SEE EXAMPLE SHEET.
  
 7)THE FRONT ENTRY DOOR INDICATES
 GLAZING, THE PRODUCT APPROVAL SUBMITTED
 FOR THIS DOOR INDICATES STORM SHUTTERS
 ARE REQUIRED.FBC 1005.4.5 (GLITCH
 AMENDMENTS JULY 1, 2003) REQUIRES AT
 LEAST ONE MEANS OF ESCAPE FROM A
 DWELLING WHEN SHUTTERED FOR IMPACT
 PROTECTION. THE MEANS OF ESCAPE SHALL BE
 WITHIN THE FIRST FLOOR OF THE DWELLING
 AND CAN NOT BE LOCATED IN A GARAGE.
 OCCUPANTS IN ANY PART OF THE DWELLING
 SHALL HAVE ACCESS TO IT WITHOUT HAVING
 TO PASS THROUGH A LOCKABLE DOOR NOT
 UNDER THEIR CONTROL. INDICATE HOW
 COMPLIANCE WILL BE ACHIEVED.
  
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-10-11 Cont ID  
Sent By jleahy Date 2005-10-11 Time 14:33 Rev Time 0.30
Received By jleahy Date 2005-10-11 Time 14:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-01-28 Cont ID  
Sent By btrobaug Date 2005-01-28 Time 13:18 Rev Time 0.50
Received By btrobaug Date 2005-01-28 Time 11:43 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-10-06 Cont ID  
Sent By adarroug Date 2005-10-06 Time 12:10 Rev Time 0.00
Received By adarroug Date 2005-10-06 Time 12:10 Sent To E
Notes
2005-10-06 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-04-27 Cont ID  
Sent By adarroug Date 2005-04-27 Time 14:08 Rev Time 0.00
Received By adarroug Date 2005-04-27 Time 14:08 Sent To B
Notes
2005-04-27 00:00:00TO "JWITMER" DESK/SRESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-11 Cont ID  
Sent By adarroug Date 2005-03-11 Time 09:14 Rev Time 0.00
Received By adarroug Date 2005-03-11 Time 09:14 Sent To B
Notes
2005-03-11 00:00:00TO "JWITMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-26 Cont ID  
Sent By mjacobs Date 2005-01-26 Time 17:43 Rev Time 0.00
Received By mjacobs Date 2005-01-26 Time 17:43 Sent To E
Notes
2005-01-26 00:00:00TO"SFR" RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-26 Cont ID  
Sent By mjacobs Date 2005-01-26 Time 07:28 Rev Time 0.00
Received By mjacobs Date 2005-01-26 Time 07:28 Sent To Z
Notes
2005-01-26 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-01-31 Cont ID  
Sent By pkrauss Date 2005-01-31 Time 12:32 Rev Time 0.35
Received By pkrauss Date 2005-01-31 Time 08:29 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-02-04 Cont ID  
Sent By kstevens Date 2005-02-04 Time 13:16 Rev Time 0.33
Received By kstevens Date 2005-02-04 Time 13:16 Sent To B1
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-26 Cont ID  
Sent By mmclean Date 2005-01-26 Time 12:02 Rev Time 0.00
Received By mmclean Date 2005-01-26 Time 12:02 Sent To I
Notes
***NONE***