Plan Review Details - Permit 05011200
Plan Review Stops For Permit 05011200
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-04-06 Cont ID  
Sent By jwitmer Date 2005-04-06 Time 08:30 Rev Time 0.50
Received By jwitmer Date 2005-04-06 Time 08:30 Sent To PC
Notes
2005-04-06 00:00:0004-06-05 REV # 2 OK JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-03-14 Cont ID  
Sent By jwitmer Date 2005-03-14 Time 17:53 Rev Time 1.66
Received By jwitmer Date 2005-03-14 Time 17:10 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-07 Cont ID  
Sent By jwitmer Date 2005-02-07 Time 11:31 Rev Time 3.33
Received By jwitmer Date 2005-02-07 Time 11:31 Sent To PC
Notes
2005-02-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05011200
 ADD: 7160 WINDING BAY LANE
 CONT: RIF GROUP
 TEL: (561)239-5790
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER
 LISTING THE ORIGINAL REVIEW COMMENT
 NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR
 SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 SHEET T1, DESIGN PARAMETERS, MISSING
 THE
  
 WIND IMPORTANCE FACTOR (1) AND BUILDING
 CATEGORY SEE ASCE7-98, ALSO EXPLAIN THE
 "BUILDING DESIGN AS CLOSED, KD=0.85,
 EXPLAIN ?
  
 3A) SHEET A3.0 TRUSS ANCHORS, ANCHOR(J)
 HIGH VALUE, ANCHOR (L) HIGH VALUE, SEE
 2005 USP VALUES.1609.4.3 LOAD
 REDUCTION.WHEN STRUCTURAL EFFECTS DUE
 TO
 TWO OR MORE LOADS IN COMBINATION WITH
 DEAD LOAD ARE INVESTIGATED IN LOAD
 COMBINATIONS OF 1609.4.1 OR 1609.4.2,
 THE COMBINED EFFECTS DUE TO THE TWO OR
 LOADS MULTI- PLIED BY 0.75 PLUS EFFECTS
 DUE TO DEAD LOADS SHALL NOT BE LESS
 THAN
 THE EFFECTS FROM THE LOAD COMBINATION
 OF
 THE DEAD LOAD PLUS THE LOAD PRODUCING
 THE LARGEST EFFECTS. INCREAS IN
 ALLOWABLE STRESS SPE CIFIED IN THE
 MATERIALS SECTIONS OF THIS CODE OR A
 REFRENCED STANDARD SHALL NOT BE USED
 WITH THESE LOAD COMBINATIONS EXCEPT
 THAT
 A DURATION OF LOAD INCREASE SHALL BE
 PERMITTED IN ACCORDANCE WITH CHAPTER
 23.
 3B) TRUSS ANCHORS REQUIRE LISTINGS FROM
 THE FLORIDA PRODUCT APPRVAL OR A LOCAL
 LISTING SEE ATTACHED FORM.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 4) SOILS REPORTS,PLANS,
 SPECIFICATIONS,REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 5) FIRM: JEFFERY SSILBERSTEIN ARCHITECT
 & ASSOCIATES, INC. FIRMS CERTIFICATE OF
 AUTHORIZATION NOT SHOWN FL S S
 481.219.(2)(3).
  
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-01-26 Cont ID  
Sent By btrobaug Date 2006-01-26 Time 14:22 Rev Time 0.50
Received By btrobaug Date 2006-01-26 Time 13:57 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-01-27 Cont ID  
Sent By btrobaug Date 2005-01-27 Time 12:49 Rev Time 0.50
Received By btrobaug Date 2005-01-27 Time 08:11 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-24 Cont ID  
Sent By adarroug Date 2006-01-24 Time 10:55 Rev Time 0.00
Received By adarroug Date 2006-01-24 Time 10:55 Sent To E
Notes
2006-01-24 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-28 Cont ID  
Sent By adarroug Date 2005-02-28 Time 15:15 Rev Time 0.00
Received By adarroug Date 2005-02-28 Time 15:15 Sent To P
Notes
2005-02-28 00:00:00TO KSTEVENS BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-26 Cont ID  
Sent By mjacobs Date 2005-01-26 Time 16:52 Rev Time 0.00
Received By mjacobs Date 2005-01-26 Time 16:52 Sent To E
Notes
2005-01-26 00:00:00TO "SFR" RACK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-26 Cont ID  
Sent By mjacobs Date 2005-01-26 Time 10:11 Rev Time 0.00
Received By mjacobs Date 2005-01-26 Time 10:11 Sent To Z
Notes
2005-01-26 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-03-09 Cont ID  
Sent By hmoser Date 2005-03-09 Time   Rev Time 0.00
Received By hmoser Date 2005-03-09 Time 17:39 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-01-28 Cont ID  
Sent By btrobaug Date 2005-01-27 Time 12:49 Rev Time 0.35
Received By pkrauss Date 2005-01-28 Time 10:29 Sent To P
Notes
2005-01-28 00:00:00PROVISO:
 PLAN INDICATES A 10" RETURN AIR JUMPER
 FROM THE BEDROOM AREA OF THE GUEST
 SUITE.THE GRILLES ARE NOT SIZED.A
 RETURN AIR JUMPER WILL ALSO BE REQUIRED
 FROM THE SUITE AREA INTO THE FAMILY
 ROOM BECAUSE THE GUEST SUITE IS
 SEPARATED FROM THE MAIN RETURN BY A
 DOOR.REFERENCE 2001 FBC(M)601.4
 EXCEPTION #1 & 3.
  
 PLEASE PROVIDE A REVISION INDICATING
 R/A
 GRILLE SIZE TO THE GUEST SUITE AND THE
 REQUIRED JUMPER INTO THE FAMILY ROOM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-03-09 Cont ID  
Sent By jleech Date 2005-03-09 Time 17:27 Rev Time 0.50
Received By jleech Date 2005-03-09 Time 17:27 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-02-04 Cont ID  
Sent By kstevens Date 2005-02-04 Time 10:18 Rev Time 0.50
Received By kstevens Date 2005-02-04 Time 10:18 Sent To B
Notes
2005-02-04 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT D1 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN, NOR DOES IT
 MEET CODE REQUIREMENTS.
 A) WASH MACHINE REQUIRES A TRAP AND A
 STANDPIPE. SECTIONS 1002.1 & 802.4
 B) WASH MACHINE AND LAUNDRY SINK SHALL
 NOT BE CONNECTED TO THE STACK ON A
 DOUBLE SANITARY TEE PATTERN. SEPARATE
 TEES REQUIRED. SECTION 706.3
 C) LANUDRY SINK IS MISLABELED AS A LAV
 SECTION 104.2.1.
 D) CLEANOUT ON LAUNDRY SINK/WASH
 MACHINE SHALL BE 4' ABOVE THE FLOOR FOR
 ACCESS. SECTION 708.10.
 E) BATHROOM BEHIND THE BAR SINK SHOWS A
 SHOWER ON THE RISER DIAGRAM, BUT SHOWS A
 TUB ON THE FLOOR PLAN. PLEASE CLARIFY.
 SECTION 104.2.1.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-26 Cont ID  
Sent By mmclean Date 2005-01-26 Time 16:18 Rev Time 0.00
Received By mmclean Date 2005-01-26 Time 16:18 Sent To I
Notes
***NONE***