Plan Review Details - Permit 05010645
Plan Review Stops For Permit 05010645
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2005-01-14 Cont ID  
Sent By ptjomsto Date 2005-01-14 Time 09:48 Rev Time 0.00
Received By ptjomsto Date 2005-01-14 Time 09:48 Sent To  
Notes
2005-01-14 00:00:00EXT REQUIRED FOR STE #105

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-18 Cont ID  
Sent By jwitmer Date 2005-02-18 Time 10:48 Rev Time 1.50
Received By jwitmer Date 2005-02-18 Time 10:43 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-24 Cont ID  
Sent By jwitmer Date 2005-01-24 Time 14:36 Rev Time 1.11
Received By jwitmer Date 2005-01-24 Time 14:36 Sent To  
Notes
2005-01-24 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05010645
 ADD: 380 COLUMBIA DR# 105
 CONT: SISCA
 TEL: (561)686-5545
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)LOUNGE DOOR REQUIRES 18" PULL SIDE;
 11-4.13.6 MANEUVERING CLEARENCES AT
 DOORS. MINIMUM MANEUVERING CLEARENCES AT
 DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL.
  
 3)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 4) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-01-21 Cont ID  
Sent By dpalmer Date 2005-01-21 Time 13:47 Rev Time 0.30
Received By dpalmer Date 2005-01-21 Time 13:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-02-07 Cont ID  
Sent By nmccray Date 2005-02-07 Time 13:23 Rev Time 0.00
Received By nmccray Date 2005-02-07 Time 13:23 Sent To  
Notes
2005-02-07 00:00:00REVIEWED AND APPROVED BY MIKE CARSILLO
 ON 02-07-05

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-04-15 Cont ID  
Sent By adarroug Date 2005-04-15 Time 15:35 Rev Time 0.00
Received By adarroug Date 2005-04-15 Time 15:34 Sent To M
Notes
2005-04-15 00:00:00TO "PKRAUSS" BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-16 Cont ID  
Sent By adarroug Date 2005-02-16 Time 13:05 Rev Time 0.00
Received By adarroug Date 2005-02-16 Time 13:05 Sent To B
Notes
2005-02-16 00:00:00TO JWITMER DESK/RESUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-14 Cont ID  
Sent By mjacobs Date   Time   Rev Time 0.00
Received By mjacobs Date 2005-01-14 Time 10:36 Sent To  
Notes
2005-01-14 00:00:00TO "COMM BD#34"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-04-22 Cont ID  
Sent By pkrauss Date 2005-04-22 Time 10:45 Rev Time 0.40
Received By pkrauss Date 2005-04-22 Time 09:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-01-26 Cont ID  
Sent By pkrauss Date 2005-01-26 Time 12:36 Rev Time 0.40
Received By pkrauss Date 2005-01-26 Time 11:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2005-02-07 Cont ID  
Sent By kstevens Date 2005-02-07 Time 12:59 Rev Time 0.25
Received By kstevens Date 2005-02-07 Time 12:59 Sent To  
Notes
2005-02-07 00:00:00NO PLUMBING PLANS/WORK SUBMITTED