2005-02-01 00:00:00 | DENIED |
| |
| 1.PROJECT DETAIL ON APPLICATIO AND |
| SCOPE OF WORK ON PLANS DOES NOT REFLECT |
| WORK TO BE DONE.COPLETE EACH IN |
| DETAIL |
| AND SHOW NEW AND EXISTING WORK. |
| |
| 2.SUBMIT 2 COPIES OF PRODUCT |
| APPROVALS |
| FOR THE FOLLOWING.WINDOWS, EXTERIOR |
| DOORS, IMPACT PROTECTION AND ROOFING. |
| ALL PRODUCT APPROVALS SUBMITTED WITH |
| QUALITY ASSURANCE REQUIRE THE FOLLOWING |
| TO BE ATTACHED. |
| PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, |
| 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR |
| INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEETS THAT |
| LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| |
| 3.ROOF FRAMING PLAN.HOW MUCH ROOF |
| FRAMING IS NEW? WILL THERE BE NEW ROOF |
| SHEATHING?PLEASE SUBMIT PLANS WITH |
| MORE INFORMATION. |
| |
| 4.BEDROOM WINDOWS SHALL COMPLY WITH |
| FBC 1005.4. PLEASE SHOW SILL HEIGHT |
| FROM |
| FLOOR. |
| |
| 5.SAFTEY GLAZING REQUIRED ON WINDOW |
| AT |
| TUB LOCATION. FBC 2405.2.1 |
| |
| 6.VALUATION OF PERMIT IS TO REFLECT |
| ALL MATERIALS AND LABOR FOR THIS |
| PROJECT.PLEASE REVISE. |
| |
| 7.A CONTRACTOR IS REQUIRED TO PULL |
| THIS PERMIT. FS 489 |
| |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| ART LANGE |
| BUILDING PLANS EXAMINER |
| 805-6672 |