Plan Review Stops For Permit 04121797 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-09-19 |
Time |
11:25 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2005-09-19 |
Time |
11:25 |
Sent To |
P |
|
Notes |
2005-09-19 00:00:00 | REV DATED 7-29-05 OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-03-31 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-03-31 |
Time |
15:05 |
Rev Time |
1.55 |
Received By |
jwitmer |
Date |
2005-03-31 |
Time |
14:42 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-02-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-02-01 |
Time |
12:01 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2005-02-01 |
Time |
12:01 |
Sent To |
PC |
|
Notes |
2005-02-01 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04121797 | | ADD: 6824 SPARROW HAWK DRIVE | | CONT: THE RIF GROUP | | TEL: (561)239-5790 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | | | | | COMMENTS FOR THIS PERMIT ARE THE SAME | | FOR PERMIT# 04121765 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-28 |
Time |
18:24 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-28 |
Time |
18:08 |
Sent To |
PC |
|
Notes |
2006-02-28 00:00:00 | REVISION, OK, STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2006-02-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-10 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-10 |
Time |
09:42 |
Sent To |
PC |
|
Notes |
2006-02-10 00:00:00 | ***** UNSAT **** | | | | 1)NOTE: PLEASE CORRELATE AHU HEAT LOADS | | ON PANEL SCHEDULE WIHT LOADS | | CALCULATIONS. | | PLEASE SEE TWO DIFFERENT LOADS ARE | | SHOWN. | | PLEASE SEE 65% OF 10KW IS NOT 7150VA, | | PLEASE ALSO SEE VA SHOWN FOR A/C AT 5KW? | | 215.5 | | | | 2)NOTE: PLEASE CORRELATE FEEDERS FOR | | PANEL "C", RISER SHOWS #3, PANEL "A" | | SHOWS #4. | | 310.16.240.40,310.15B6, 215.5 | | | | 3)NOTE: PLEASE CORRELATE FEEDERS FOR | | PANEL "B", RISER SHOWS #8'S AND SHOWS | | #12 ON PANEL SCHEDULE "A". PLEASE ALSO | | SEE NEITHER SETS OF FEEDERS ARE RATED | | FOR THE 80A BRKR FEEDING PANEL "B". | | 240.4,310.15B6,310.16 ,215.5 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2006-01-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-23 |
Time |
17:55 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-23 |
Time |
17:35 |
Sent To |
PC |
|
Notes |
2006-01-23 00:00:00 | ********** UNSAT ********** | | | | 1)NOTE: PLEASE SEE NOTE #10 ON E-2 WHICH | | INDICATES 250.95, WHICH IS FROM THE 1996 | | NEC. THIS HAS BEEN REDLINED ON PREVIOUS | | PLANS, HOWEVER PLEASE CORRECT AT THIS | | TIME. | | | | 2)NOTE: PLEASE SEE MIN VA SHALL BE 1.5KW | | FOR SMALL APPL, WAS/LAUNDRY CIRCUITS. | | 220.12 | | SHOWS 1.0 | | | | 3)NOTE: PLEASE VERIFY ALL LOADS IN PANEL | | "C" AS BOTH CU'S INDICATE LOAD TOGETHER | | AS 2.8VA. THIS IS NOT POSSIBLE AS UNITS | | ARE TOO LARGE FOR THIS LOW OF A LOAD. | | PLEASE ALSO SEE LOAD FOR SPRINKLER TIME | | CLOCK, IS THIS A PUMP OR ONLY TC.VERIFY | | LOAD.? | | PLEASE SEE LOADS ARE NOT COMPLETE IN | | THIS PANEL "C". | | | | | | 4)NOTE: PLEASE SEE PANEL "A" SHOWS KW | | RATING AT 10KW , HOWEVER LOAD CALCS | | INDICATE BOTH OF THESE AT 7.15 KW? | | PLEASE EXPLAIN OR SHOW. IF DE-RATING IS | | BEING CALCULATED , THEN PLEASE SHOW. | | | | 5)NOTE: PLEASE SEE KITCHEN ISLAND WHERE | | THE GFI LABEL SEEMS TO BE LOCATED OFF | | THE RECEPT IN WHICH IT IS SUPPOSE TO | | LABEL. (MISPRINT). PLEASE SEE ONE SET IS | | REDLINED FOR THIS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-09-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-03 |
Time |
09:32 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-09-03 |
Time |
09:32 |
Sent To |
P |
|
Notes |
2005-09-03 00:00:00 | RETAINED FILE COPY OF ELEC REV. | | ONLY CONTRACTORS COPY IN PACKAGE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-03-23 |
Time |
12:50 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-03-23 |
Time |
12:37 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-01-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-01-06 |
Time |
12:33 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-01-06 |
Time |
12:20 |
Sent To |
M |
|
Notes |
2005-01-06 00:00:00 | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1}THE PLAN SHOWS A METER/MAIN AND THE | | RISER SHOWS A PANEL AND METER SEPERATE, | | PLEASE CORRELATE. | | | | NOTE: USING FIVE 2-POLE BREAKERS AS | | "MAINS" IN A TWELVE SPACE PANEL LEAVES | | ROOM FOR TWO SINGLE POLE BREAKERS, NOT | | MEETING THE INTENT OF THE SIX MEANS OF | | DISCONNECT IN ARTICLE 230.70, 71 OR THE | | EXCEPTIONS OUTLINED IN 230.40. | | | | 2} THE DEMAND CALCULATION SHOWS A/C #1 | | & | | #2 AS 5000 WATTS, PANELSCHEDULE SHOWS | | 11000, AND THE LOADS ARE SHOWN AS 7150 | | W | | AFTER DEMAND . PLEASE CORRELATE. | | | | 3} NOTE: THE LOAD CALCULATION AFTER | | DEMAND IS 199 AMPS ON A 200 AMP SERVICE | | LEAVING NO ROOM FOR FUTURE ADDITIONAL | | LOADS. WHILE THIS SERVICE DOES MEET THE | | MINIMUM CRITERIA A LARGER SERVICE IS | | RECOMMENDED. | | | | 4} THE TERM "ARCHITECTS" IN THE TITLE | | BLOCK INDICATES A FIRM OR BUSINESS AND | | THEREFORE REQUIRES A CERTIFICATE OF | | AUTHORIZATION NUMBER ALSO ON THE TITLE | | BLOCK PER 61G1-16.004(2) FAC. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-02-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-24 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-24 |
Time |
09:45 |
Sent To |
E |
|
Notes |
2006-02-24 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-03 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-03 |
Time |
16:46 |
Sent To |
E |
|
Notes |
2006-02-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-01-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-17 |
Time |
18:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-17 |
Time |
18:14 |
Sent To |
E |
|
Notes |
2006-01-17 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-08-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-31 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-31 |
Time |
11:35 |
Sent To |
I |
|
Notes |
2005-08-31 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-03-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-22 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-22 |
Time |
09:14 |
Sent To |
E |
|
Notes |
2005-03-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-01-04 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-04 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-04 |
Time |
14:57 |
Sent To |
E |
|
Notes |
2005-01-04 00:00:00 | TO "SFR" RACK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-03 |
Time |
10:20 |
Sent To |
Z |
|
Notes |
2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-01-10 |
Time |
14:25 |
Rev Time |
0.45 |
Received By |
prafter |
Date |
2005-01-10 |
Time |
14:24 |
Sent To |
P |
|
Notes |
2005-01-10 00:00:00 | RETURN AIR OF MASTER BEDROOM AREA JUMPER | | MUST BE 15# OR LARGER. 2001 F.B.C./M | | 601.4 EXCEPTION #1 . |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-09-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-09-14 |
Time |
13:20 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-09-14 |
Time |
13:20 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-01-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-01-12 |
Time |
08:47 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-01-12 |
Time |
08:47 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-01-04 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-01-04 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-01-04 |
Time |
14:33 |
Sent To |
I |
|
Notes |
|
|