Plan Review Stops For Permit 04121181 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-03-07 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-03-07 |
Time |
10:00 |
Sent To |
|
|
Notes |
2005-03-07 00:00:00 | SEE PROVISO FROM LAST REVIEW. | | WILL CHANGE STATUS TO PASS WHEN PRODUCT | | APPROVALS ARE RETURNED. RM |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-02-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-02-22 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-02-22 |
Time |
11:21 |
Sent To |
|
|
Notes |
2005-02-22 00:00:00 | PROVISO | | | | 1) SUBMIT MANUFACTURER'S SPECIFICATIONS | | FOR THE VENTLESS FOAM INSULATION SYSTEM. | | | | 2) SUBMIT A LETTER FROM THE FIREPLACE | | AND CHIMNEY MANUFACTURER APPROVING THE | | CHINEY CAP ENCLOSURE SHOWN ON THE PLANS. | | | | 3) SUBMIT TWO COPIES OF AN INSTALLATION | | SCHEDULE AND KEY PLAN FOR THE STORM | | PANELS BEFORE THEY ARE INSTALLED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-01-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-01-12 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-01-12 |
Time |
08:54 |
Sent To |
|
|
Notes |
2005-01-12 00:00:00 | DENIED | | | | 1)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 2)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 3) SUBMIT A SURVEY INDICATING THE | | LOCATION OF THE STRUCTURE ON THE LOT. | | | | 4) THE LOCATIONS OF SEVERAL OF THE | | FILLED CELLS ARE MISSING FROM THE | | FOUNDATION PLAN ON A1. | | | | 5) SPECIFY THE EMBED DEPTH OF THE 1/2" | | DIA. BOLTS ON THE O.H. GARAGE DOOR BUCK | | DETAIL ON A 2. | | | | 6) SPECIFY THE LOCATIONS OF THE DRAFT | | STOPS DIVIDING THE FLOOR/CEILING | | ASSEMBLY INTO AREAS OF 500 SQFT AS | | REQUIRED BY FBC 2305.2.2. | | | | 7) SUBMIT MANUFACTURERS SPECIFICATIONS | | AND INSTALLATION INSTRUCTIONS FOR THE | | FOAM INSULATION THAT WILL BE USED IN | | CONJUNCTION WITH THE UNVENTED ATTIC. | | ALSO SEE ATTACHMENT. | | | | 8) THE MEAN ROOF HEIGHT OF LESS THAN 20' | | LISTED ON SHEETS A4 AND A6 IS INCORRECT. | | THE MRH (DISTANCE FROM GRADE TO AVERAGE | | HEIGHT OF THE ROOF) IS JUST OVER 26'. | | PLEASE CORRECT. | | | | 9) REVISE ROOF SHEATHING NAILING NOTES | | ON A4. THE OUTSIDE CORNERS OF HIP ROOFS | | ARE ZONE 3. SHEATING IN ZONE 3 IS | | REQUIRED TO BE NAILED AT 4'OC AT EDGES | | AND 6'OC INTERMEDIATE WITH 8D RING-SHANK | | NAILS PER CITY OF WPB AMENDMENTS TO FBC | | TABLE 2306.1. | | | | 10) REVISE THE ROOF SHEATHING FASTENING | | NOTES AT THE ONE AND TWO STORY WALL | | SECTIONS ON A5. | | | | 11) PLEASE CORRECT THE NUMBER OF | | FASTENERS SPECIFIED FOR TRUSS CONNECTOR | | #4 IN THE SCHEDULE ON A4. THE SIMPSON | | CATALOG SPECIFIES (15) 10D X 1-1/2" | | NAILS FOR THE HETAL 20. | | | | 12) PROVIDE A FASTENING DETAIL FOR THE | | LEDGER CARRYING THE ROOF TRUSSES AT THE | | CHIMNEY. | | | | 13) SUBMIT A LETTER FROM THE | | MANUFACTURER OF THE FIREPLACE AND | | CHIMNEY SPECIFYING THAT THE CHIMNET | | TERMINATION CAP CAN BE ENCLOSED AS SHOWN | | ON THE PLANS. ADDRESS THE FIRE HAZARD | | AND THE ABILITY OF THE UNIT TO DRAFT | | PROPERLY. | | | | 14) SUBMIT A KEY PLAN AND INSTALLATION | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | WHICH OPENINGS WILL BE SHUTTERED. | | SPECIFY THE MOUNT TYPE, FASTENER TYPE | | AND SPACING. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-03-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-03-04 |
Time |
06:41 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-03-04 |
Time |
06:41 |
Sent To |
B |
|
Notes |
2005-03-04 00:00:00 | ELEC STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-02-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-07 |
Time |
08:45 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-02-07 |
Time |
08:45 |
Sent To |
P |
|
Notes |
2005-02-07 00:00:00 | ********* UNSAT 2ND REVIEW ********** | | | | PLEASE SEE SOME COMMENTS FROM PREVIOUS | | REVIEW STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE PLANS WHICH ARE | | SIGNED, DATED AND SEALED BY THE ENGINEER | | MUST CONTAIN A TITLE BLOCK FOR THE | | ENGINEER OF RECORD CONTAINING ALL | | INFORMATION AS REQUIRED UNDER FAC | | 61G15-23.002. | | | | | | 2)NOTE: PLEASE CORRELATE LOAD | | CALCULATIONS, SUB-PANEL IS SHOWN W/ 25KW | | LOAD AND MAIN PANEL INDICATES 10KW? | | PLEASE SEE 220.31 FOR LOAD | | CALCULATIONS. | | PLEASE SEE 220.3B4, THIS IS A TOTAL # OF | | FIXTURES X THE WATTAGE PER FIXTURE ADDED | | TO LIGHTING LOAD CALCS. | | | | | | NEW COMMENTS DUE TO CHANGE IN RISER | | DIAGRAM AND ADDED PANEL SCHEDULE. | | | | 1)NOTE: PLEASE SEE REQUIRED FOOTER STEEL | | HAS NOW BEEN REMOVED FROM RISER | | DIAGRAM? | | PLEASE SEE 250.50. | | | | 2)NOTE: PLEASE SEE SMALL APPL CIRCUIT IS | | SHOWN W/ 3KW LOAD ON A 20A CIRCUIT. | | PLEASE SEE MAX KW FOR A 20A CIRCUIT IS | | 1950W'S. PLEASE ADJUST. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-12-30 |
Time |
16:13 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-12-30 |
Time |
16:13 |
Sent To |
M |
|
Notes |
2004-12-30 00:00:00 | *************** UNSAT ************* | | | | 1)NOTE: PLEASE SEE PLANS WHICH ARE | | SIGNED AND SEALED BY THE ENGINEER ARE | | REQUIRED TO HAVE A TITLE BLOCK WITH ALL | | INFORMATION AS SET-FORTH IN FAC | | 61G15-23.002. PLEASE SEE ELECTRICAL | | PLANS DO NOT CONTAIN ANY TITLE BLOCK FOR | | ENG. | | PLEASE SEE ALL PLANS ARE REQUIRED TO | | HAVE THE PRINTED NAME AND SIAGNATURE OF | | PERSON RESPONSIBLE FOR PLANS/DESIGN. PER | | FBC 104.2.1 THIS IS REQUIRED ON ALL | | PLANS AND FOR ALL TRADES WHEATHER OR NOT | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | 2)NOTE: SMOKE DETECTORS ARE REQUIRED | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | UNIT. | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | TO FLOORS ABOVE AND IN THE VICINITY OF | | BEDROOMS. | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | A MIN OF 3' FROM BATHROOM DOORS AND | | KITCHENS. | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | PLEASE SEE MOST HAVE BEEN REDLINED ON | | PLANS FOR LOCATIONS REQUIRED. | | | | 3)NOTE: PLEASE CORRELATE PLANS WITH | | PANEL SCHEDULE AND LOAD CALCULATIONS FOR | | WATER HEATER, OVEN/RANGE AND DRYER. | | PLANS SHOW AS GAS AND ELECTRICAL WITH | | LOADS ACCORD. | | PLEASE SEE WATER HOWEVER SHOWS A LOAD OF | | 4500W ON A 20A CIRCUIT. | | PLEASE SEE 422.13, REQUIRES MIN RATING | | OF 125%. | | | | 4)NOTE: PLEASE VERIFY OCP FOR AHU #2, | | THIS SHOWS 60A OCP FOR 7.5KW UNIT. | | 424.3B REQUIRES A MIN 125% . MAX MAY BE | | 150% FOR OCP. | | | | 5 )NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | 6 )NOTE: PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CURCUIT(S) ON PANEL | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | IN BEDROOMS ARE TO BE PROTECTED , | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | 7)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | ON PLANS. | | | | 8)NOTE: PLEASE INDICATE PANEL AS MCB. | | 225.31,240.4B,ETC. | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | ONE SET OF OLD SHEETS SHOULD BE | | SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2005-02-12 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-02-12 |
Time |
06:03 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-02-12 |
Time |
06:02 |
Sent To |
P |
|
Notes |
2005-02-12 00:00:00 | SEPERATE PLANS AND PERMIT FOR GAS PIPING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-03-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-15 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-15 |
Time |
15:03 |
Sent To |
P |
|
Notes |
2006-03-15 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-01-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-20 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-20 |
Time |
12:25 |
Sent To |
P |
|
Notes |
2006-01-20 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-03-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-03 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-03 |
Time |
11:38 |
Sent To |
I |
|
Notes |
2005-03-03 00:00:00 | TO DPALMER DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-04 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-04 |
Time |
11:37 |
Sent To |
E |
|
Notes |
2005-02-04 00:00:00 | TO "DP" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-02-01 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-02-01 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-02-01 |
Time |
11:16 |
Sent To |
Z |
|
Notes |
2005-02-01 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-12-30 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-30 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-30 |
Time |
07:58 |
Sent To |
E |
|
Notes |
2004-12-30 00:00:00 | TO "SFD RACK" E. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-12-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-22 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-22 |
Time |
13:11 |
Sent To |
Z |
|
Notes |
2004-12-22 00:00:00 | SENT TO "Z" BOX. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-01-03 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-01-03 |
Time |
12:20 |
Rev Time |
0.45 |
Received By |
prafter |
Date |
2005-01-03 |
Time |
12:20 |
Sent To |
B |
|
Notes |
2005-01-03 00:00:00 | | | PROVISO.TALK TO MIKE WILLIAMS1/03/05 | | 11:30 AM | | | | 1. DUCT SIZE TO BEDROOM 2. REQUIRE 10 " | | SUPPLY AIR DUCT . | | 2. RETURN AIR FROM BEDROOM 2. REQUIRE | | 14" JUMPER WITH 16"X16" RT GRILLS . | | | | PAT RAFTER561/805/6719 . | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-03-20 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-03-20 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-03-20 |
Time |
15:17 |
Sent To |
|
|
Notes |
2006-03-20 00:00:00 | ADDED VEG. SINK. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-02-12 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-02-12 |
Time |
06:07 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-02-12 |
Time |
06:07 |
Sent To |
B1 |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-01-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-01-03 |
Time |
09:16 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2005-01-03 |
Time |
09:16 |
Sent To |
M |
|
Notes |
2005-01-03 00:00:00 | DENIED; | | 1.KITCHEN SINK MUST DISCHARGE DOWN | | STREAM OF HALF BATH. FBC PLUMBING SEC. | | 909.1. | | 2.TUB AND SHOWER IN MASTER BATHROOM ARE | | NOT VENTED. | | 3.PLEASE CHANGE NOTES. SHOWER HEADS TO | | COMPLY WITH FBC PLUMBING TABLE 604.4.ALL | | TUB AND SHOWER VALVES TO BE ANTI-SCALD | | TYPE. NOTE 2 ONE VENT MUST EXTEND THRU | | ROOF TO THE OUT SIDE. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-02-04 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-02-04 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-02-04 |
Time |
15:28 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2004-12-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-12-29 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-12-29 |
Time |
16:25 |
Sent To |
I |
|
Notes |
2004-12-29 00:00:00 | DENIED, NEED A SCALED SITEPLAN SHOWING | | THE SETBACKS FOR THE CHIMENEY AND OTHER | | OR SHOW ON THE SURVEY.CALLED CONTR | | LEFT MSG ON VOICE MAIL. |
|
|