Plan Review Details - Permit 04121136
Plan Review Stops For Permit 04121136 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-01-12 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2005-01-12 |
Time |
08:48 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2005-01-12 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-14 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-02-14 |
Time |
10:25 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-12-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-12-28 |
Time |
16:40 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-12-28 |
Time |
16:40 |
Sent To |
P |
|
Notes |
2004-12-28 00:00:00 | ************ UNSAT *********** | | | | 1)NOTE: PLEASE SEE WIRING DIAGRAM | | INDICATES A NEW PANEL. | | PLEASE INCLUDE FEED TO NEW PANEL, OCP, | | AWG, CONDUIT ETC. | | PLEASE ALSO INCLUDE PANEL SCHEDULE FOR | | NEW PANEL WITH CIRCUITS FOR NEW | | EQUIPMENT.215.5 | | | | 2)NOTE: PLEASE BE SURE RAISED SEAL IS | | CLEAR AND VISABLE WITH ALL INFORMATION | | ON SEAL. FS 471.025 | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-12-28 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-28 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-28 |
Time |
07:39 |
Sent To |
E |
|
Notes |
2004-12-28 00:00:00 | TO "E" BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-12-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-22 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-22 |
Time |
09:16 |
Sent To |
Z |
|
Notes |
2004-12-22 00:00:00 | SENT TO "Z" BOX. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-01-10 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-01-10 |
Time |
13:44 |
Sent To |
B |
|
Notes |
2005-01-10 00:00:00 | PROVISO: | | BACK FLOW PREVENTER INSTALLED PRIOR TO | | COMMENCING WORK ON POOL. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-12-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-12-27 |
Time |
15:28 |
Rev Time |
0.25 |
Received By |
mmclean |
Date |
2004-12-27 |
Time |
15:28 |
Sent To |
I |
|
Notes |
2005-02-14 00:00:00 | OK, RISER REVISED BY ENGINEER, TO READ | | PANEL SHOWN AS EXISTING. |
|
|
|