Plan Review Stops For Permit 04111262 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2004-12-03 |
|
|
Cont ID |
|
Sent By |
jhiggins |
Date |
2004-12-03 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2005-06-17 |
Time |
14:03 |
Sent To |
|
|
Notes |
2004-12-03 00:00:00 | ADDRESS OK,LOT/BLOCK= 14TH FL, PH 4 | 2004-12-02 00:00:00 | OWNER UPDATE |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2005-07-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-07-11 |
Time |
12:01 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-07-11 |
Time |
12:01 |
Sent To |
PC |
|
Notes |
2005-07-11 00:00:00 | REVISED SHEET D2 (2A, 2B, D3 ALREADY | | REVIEWED BY JW) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-06-17 |
Time |
14:09 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2005-06-17 |
Time |
14:03 |
Sent To |
|
|
Notes |
2005-06-17 00:00:00 | REVISION 6-02-05JW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2005-06-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-06-03 |
Time |
09:50 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-06-03 |
Time |
09:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-06-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-06-03 |
Time |
09:32 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-06-03 |
Time |
09:29 |
Sent To |
PC |
|
Notes |
2005-06-03 00:00:00 | 06-03-05 RE: FLOOR X-RAYS (8)JW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-02-08 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2005-06-03 |
Time |
09:29 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-12-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-12-15 |
Time |
09:55 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2004-12-15 |
Time |
08:58 |
Sent To |
|
|
Notes |
2004-12-15 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04111262 | | ADD: 622 N FLAGLER PH 4 | | CONT:FIRST CONSTRUCTION | | TEL: (561)358-9289 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | | | 1) FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | DISCREPANCY, BETWEEN SHEETS 2A, 2B & | | D-1. SEE THE REQUIREMENT 1007.8.3 FOR | | TREAD DEPTH NOT BEING LESS THAN 11" | | MEASURED 12" FROM THE SMALL RADIUS. | | | | 2) PROVIDE WHAT MATERIALS THE STRINGERS | | WILL BE MANUFACTURED FROM. SEE 1007.1.1 | | NONCOMBUSTIBLE MATERIALS FOR A TYPE I OR | | TYPE II BLDGS. | | | | 3) SHEET D-1 PROVIDE THE SPACING BETWEEN | | THE UPRIGHT PICKETS, | | 1015.3 OPENINGS. OPEN GUARDRAILS | | SHALL HAVE INTERMEDIATE RAILS OR ORNA- | | MENTAL PATTERNS SUCH AS A 4" DIAMETER | | SPHERE CAN NOT PASS THROUGH. A BOTTOM | | RAIL OR CURB SHALL BE PROVIDED THAT WILL | | REJECT THE PASSAGE OF 2" DIAMETER | | SPHERE. | | | | 4) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 5) TYPE I /II BLDG NO COMBUSTIBLES IN | | WALLS 609.2.1. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-30 |
Time |
17:44 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-06-30 |
Time |
17:41 |
Sent To |
FIRE |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-06-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-06-20 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-06-20 |
Time |
15:41 |
Sent To |
|
|
Notes |
2005-06-20 00:00:00 | ****** UNSAT ****** | | | | 1)NOTE: PLEASE SEE ALL NEW CIRCUITING | | FOR BATH GFI RECEPTS. THESE MUST BE 20A | | AND #12. 210.52D,210.11C3 | | | | 2)NOTE: PLEASE SEE A MIN OF 1.5KW | | REQUIRED FOR LAUNDRY/WASHER CIRCUIT. | | 220.16 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-12-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-12-01 |
Time |
07:12 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-12-01 |
Time |
07:11 |
Sent To |
|
|
Notes |
2004-12-01 00:00:00 | REMODEL/RELOCATION OF EXISTING | | ELECTRICAL. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2005-07-05 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-07-05 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-07-05 |
Time |
13:21 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-02-07 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-02-07 |
Time |
12:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-12-22 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-12-22 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-12-22 |
Time |
14:56 |
Sent To |
|
|
Notes |
2004-12-22 00:00:00 | FIRE REVIEW REF NFPA 101 LIFE SAFETY | | CODE 2000 EDITION | | | | 1) NFPA 101 CODE TABLE 7.2.2.2.1 (A) NEW | | STAIRS | | | | 2) NFPA 101 CODE 30.3.3.2 INTERIOR | | FINISH FOR WALLS AND CEILINGS SHALL BE | | MINIMUM OF CLASS "C". | | | | 3) SEPARATE PLANS AND PERMIT | | APPLICATIONS ARE REQUIRED FOR FIRE | | SPRINKLER SYSTEM REMODEL. | | | | | | NATE MCCRAY, CAPTAIN | | 561-835-2910 OR 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-20 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-20 |
Time |
14:30 |
Sent To |
P |
|
Notes |
2005-07-20 00:00:00 | TO "P" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-07-08 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-07-08 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2005-07-08 |
Time |
14:02 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-06 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-06 |
Time |
09:35 |
Sent To |
B |
|
Notes |
2005-07-06 00:00:00 | TO "JWITMER" DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-06-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-06-28 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-06-28 |
Time |
10:09 |
Sent To |
E |
|
Notes |
2005-06-28 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-08 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-06-08 |
Time |
15:09 |
Sent To |
|
|
Notes |
2005-06-16 00:00:00 | COMM BOARD #55 | | | 2005-06-08 00:00:00 | WAITING FOR COMM BOARD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-24 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-24 |
Time |
16:05 |
Sent To |
B |
|
Notes |
2005-05-24 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-01-26 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-26 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-26 |
Time |
10:53 |
Sent To |
|
|
Notes |
2005-01-26 00:00:00 | TO "COMM BD#11/RESUB." |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
|
Time |
|
Rev Time |
|
Received By |
mjacobs |
Date |
2004-11-24 |
Time |
12:18 |
Sent To |
|
|
Notes |
2004-11-24 00:00:00 | SENT TO "AD"BOX FOR PCN CLARIFICATION. | | PLANS COMM BD#11 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-03-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-02-02 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-02-02 |
Time |
08:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-07-08 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-07-08 |
Time |
14:28 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2005-07-08 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-02-08 |
Time |
08:22 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-01-29 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-01-29 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-01-29 |
Time |
13:41 |
Sent To |
FIRE |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-12-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-12-23 |
Time |
17:54 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-12-23 |
Time |
17:54 |
Sent To |
|
|
Notes |
2004-12-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SHT D1 SANITARY RISER DIAGRAM. THIS | | IS A SOVENT SYSTEM AND AS SUCH IS AN | | ENGINEERED SYSTEM. THE STACK THAT THE | | NEW BATHROOM IS BEING TIED INTO SHALL BE | | SHOWN AS EXISTING. SHOW WHERE THE NEW | | BATHROOM IS CONNECTED TO THE SOVENT | | STACK. INDICATE THE DEVELOPED LENGTH OF | | THE PIPING FROM THE STACK TO THE | | FIXTURES. SHOW THE AERATOR AND IF THERE | | IS AN OFFSET THE DEAERATOR REQUIRED FOR | | THIS ADDED BATHROOM. SECTION 104.2.1 | | 2) SUBMIT A WATER RISER DIAGRAM SHOW THE | | CONNECTION TO THE EXISTING WATER IN THE | | UNIT AND ALL PIPE SIZES, WATER HAMMER | | ARRESTORS ECT. SECTION 104.3.1.1. | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|