Plan Review Details - Permit 04110885
Plan Review Stops For Permit 04110885
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-11-17 Cont ID  
Sent By jwitmer Date 2004-11-17 Time 11:39 Rev Time 0.00
Received By jwitmer Date 2004-11-17 Time 11:39 Sent To PC
Notes
2004-11-17 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04110885
 ADD: 732 NATHAN HALERD
 CONT: PAUL E HAHN CCC023528
 TEL: (561)721-5908
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: REVIEWED
  
 1507.3.8 UNDERLAYMENT APPLICATION
 FOR ROOF SLOPES FROM 2:12 TO 4:12,
 UNDERLAYMENT SHALL BE A MINIMUM OF TWO
 LAYERS APPLIED AS FOLLOWS:
 1) STARTING AT THE EAVE, A 19-INCH
 STRIP OF UNDERLAYMENT SHALL BE APPLIED
 PARALLEL WITH THE EAVE AND FASTENED
 SUFFICIENTLY TO STAY IN PLACE.
 2) STARTING AT THE EAVE, 36-INCH-WIDE
 STRIPS OF UNDERLAYMENT FELT SHALL BE
 APPLIED OVER-LAPPING SUCCESSIVE SHEETS
 19"AND FASTENED SUFFICIENTLY TO STAY
 IN PLACE.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved