Plan Review Stops For Permit 04110588 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
N |
Date |
2005-01-13 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-01-13 |
Time |
10:12 |
Rev Time |
0.25 |
Received By |
alange |
Date |
2005-01-13 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-12-08 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-12-08 |
Time |
09:09 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2004-12-08 |
Time |
09:09 |
Sent To |
|
|
Notes |
2004-12-08 00:00:00 | DENIED | | | | INSUFFICIENT INFORMATION PROVIDED FOR A | | BUILDING REVIEW. | | SHOW ON PLANS NEW AND EXISTING WORK | | BEING DONE, SHOW USE, IS A GARAGE OR | | LIVING SPACE. | | IF IT IS A HABITABLE AREA THE FINISH | | FLOOR SHALL BE A MINIMUM OF 4" ABOVE | | FINISH GRADE. | | | | SUBMIT DETAILS FOR NEW FRAMING AND | | PRODUCT APPROVALS FOR EXTERIOR DOORS, | | WINDOWS AND ROOFING. | | | | ANY QUESTIONS CALL ME. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-01-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-01-06 |
Time |
16:22 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-01-06 |
Time |
15:57 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-11-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-11-18 |
Time |
18:35 |
Rev Time |
0.00 |
Received By |
BTROBAUG |
Date |
2004-11-22 |
Time |
14:16 |
Sent To |
Z |
|
Notes |
2004-11-18 00:00:00 | | | SPOKE WITH OWNER WHO SAID THIS SPACE | | WAS A LEGALLY REQUIRED GARAGE, AM | | SENDING TO ZONING FOR OPINION./WRT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-01-05 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-05 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-05 |
Time |
08:41 |
Sent To |
E |
|
Notes |
2005-01-05 00:00:00 | TO "BT" DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-03 |
Time |
14:05 |
Sent To |
Z |
|
Notes |
2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-11-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-11-22 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2004-11-22 |
Time |
14:17 |
Sent To |
P |
|
Notes |
2004-11-22 00:00:00 | BACK FROM ZONING, TO PLUMB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-11-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-11-10 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-11-10 |
Time |
14:08 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2005-01-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-01-12 |
Time |
10:07 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2005-01-12 |
Time |
10:07 |
Sent To |
B |
|
Notes |
2005-01-12 00:00:00 | NO PLUMBING PLANS SUBMITED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-11-27 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-11-27 |
Time |
05:17 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-11-27 |
Time |
05:16 |
Sent To |
B1 |
|
Notes |
2004-11-27 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | | | 1) MORE INFORMATION IS REQUIRED. PERMIT | | APPLICATION STATES "INSTALL WATER HEATER | | ELECTRIC OUTLETS", BUT IT SEEMS THAT | | MORE WORK IS SHOWN ON THE PLANS. WITH | | THE ADDITION OF A SANITARY RISER DIAGRAM | | IT SEEMS THAT A BATHROOM IS BEING | | ADDED. | | ALSO IT SEEMS THAT A WASH MACHINE IS | | BEING ADDED TO THE HOUSE. WILL THE | | BATHROOM BE FRAMED IN OR IS IT | | EXISTING? | | 2) SHT PL:1 SANITARY RISER DIAGRAM DOES | | NOT MEET CODE REQUIREMENTS. | | A) PLEASE SHOW ALL PIPE SIZES AND | | IDENTIFY ALL FIXTURES. SECTION 104.2.1 | | B) TRAPS ARE REQUIRED AT THE SHOWER, | | THE LAV., AND THE WASH MACHINE. SECTION | | 1002.1 | | C) THE WASH MACHINE REQUIRES A | | STANDPIPE AND SHALL HAVE A CLEANOUT | | INSTALLED 4 FEET ABOVE THE FLOOR FOR | | ACCESS. SECTIONS 1002.1 & 708.10 | | D) THE TWO 2" DRAINS ARE NOT VENTED, | | AND PIPED AS SUCH WILL BE AN "S" TRAP. | | SECTIONS 902.1 & 1002.3(5) | | E) ONLY THE FIXTURES WITHIN THE | | BATHROOM GROUPS SHALL CONNECT TO THE | | WET-VENTED HORIZONTAL BRANCH DRAIN. ANY | | ADDITIONAL FIXTURES SHALL DISCHARGE | | DOWNSTREAM OF THE WET VENT. SECTION | | 909.1 (THE WASH MACHINE SHALL CONNECT | | DOWNSTREAM OF THE BATHROOM FIXTURES). | | 3) ALL DRAWINGS SHALL BEAR THE NAME AND | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | THE DESIGN. SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-01-04 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-01-04 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-01-04 |
Time |
16:29 |
Sent To |
I |
|
Notes |
2005-01-04 00:00:00 | OK FOR INTERIOR WORK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2004-11-22 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-11-22 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-11-22 |
Time |
13:02 |
Sent To |
E |
|
Notes |
2004-11-22 00:00:00 | DENIED, NEED TO PROVIDE A COMPLETE FLOOR | | PLAN OF THE EXISTING AND REMODEL PLANS. | | CAN EITHER CONVERT APARTMENT BACK TO | | GARAGE OR MAKE IT APART OF THE MAIN | | STRUCTURE. |
|
|