Plan Review Stops For Permit 04110183 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
16 |
Status |
P |
Date |
2007-05-21 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2007-05-21 |
Time |
18:45 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2007-05-21 |
Time |
18:45 |
Sent To |
|
|
Notes |
2007-05-21 18:45:30 | REVISION SUBMITTED ON 5/4/07 FOR MULLIONS AND SUBMITTAL | | FOR SGD AND SH WINDOW ENGINEERING. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
15 |
Status |
F |
Date |
2007-04-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-04-18 |
Time |
16:17 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2007-04-18 |
Time |
16:17 |
Sent To |
PC |
|
Notes |
2007-04-18 16:18:30 | BUILDING PLAN REVIEW | | PERMIT: 04110183 | | ADD: 3900 N FLAGLER DR BLDG 1/3 | | CONT: THE WEITZ CO. | | TEL: (561)723-4084 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)THE REVISIONS SUBMITTEDAPRIL 13/2007 WHICH | | INCLUDE MIAMI WALL SYSTEMS : | | 100 ALUMINIUM SLIDIG GLASS DOORS LARGE AND SMALL MISSLE | | IMPACT RESISTANT UNITS: | | MIAMI-DADE NOA: | | 04-0908.022001 FBC- LARGE & SMALL MISSLE 100 | | ALUMINUM SLIDING GLASS DOORS | | 01-1108.032001 FBC- SMALL MISSLE 100 ALUMINUM | | SLIDING GLASS DOORS | | 03-1008.032001 FBC- LARGE MISSLE 122 ALUMINUM | | SINGLE HUNG WINDOW | | 03-1008.042001 FBC- SMALL MISSLE 122 ALUMINUM | | SINGLE HUNG WINDOW | | | | THIS MORNINGS VISIT TO THE JOBSITE WITH HAROLD PISKURA | | WE WERE ABLE TO VERIFY THE GLASS THICKNESS USED IN EACH | | OF THE INSTALLATION SINGLE HUNG WINDOWS AS WELL AS THE | | SLIDING GLASS DOORS. THE CONCERNS ARE AS FOLLOWS IN | | THIS EXAMPLE: | | | | 1A) WHERE ON THE SLIDING GLASS DOORS WE ARE ABLE TO | | VERIFY THE GLASS THICKNESS OF 9/16" FOR THE SLIDING | | GLASS DOORS WE ARE NOT ABLE TO VERIFY AS TO WHICH | | LAMINATE | | WAS INSTALLED IN EACH OF THE UNITS. THE NOA 04-0908.02 | | TECHNICAL SHEET 1 OF 4 CLEARLY INDICATES ALL GLASS | | TYPES ARE 9/16" THICK ONLY GLASS TYPES A & B CAN MAKE | | THE WIND | | LOADS ABOVE +/- 70. THE FRAMES OF THIS UNIT INDICATE | | THEY HAVE THE HEAVY REINFORCEMENT FOUND INNOA | | 01-1108.03/ FTL# 1743. | | | | 1B)THE SECOND CONCERN IS THE FRAMES LISTED UNDER | | MIAMI WALL SYSTEMS, INC SGDSMALL MISSLE LAM GLASSNOA | | 01-1108.03TECHNICAL SHEETS 2-5 INDICATE THE SLIDING | | GLASS DOOR UNITS WITH NO REINFORCEMENT, LIGHT, MEDIUM | | AND HEAVY REINFORCEMENT AND THE ASSOCIATED PRESSURES. | | AGAIN WE HAVE NO WAY OF VISUALLY INSPECTING THE | | INSTALLED FRAMES AND | | VERIFYING WHAT TYPE OF REINFORCEMENT IS IN THE FRAME IF | | ANY, THUS HAVING LOW PRESSURES. NO APPROVAL LABELS ON | | DOORS OR WINDOWS. | | | | 1707.4.2.1 TESTING AND LABELING. EXTERIOR WINDOWS AND | | GLASS DOORS | | SHALL BE TESTED BY AN APPROVED INDEPENDENT TESTING | | LABORATORY, AND | | SHALL BE LABELED WITH AN APPROVED LABEL IDENTIFYING | | THE MANUFACTURER, | | PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT | | CERTIFICATION AGENCY, | | TESTING LABORATORY, EVALUATION ENTITY OR MIAMI-DADE | | NOTICE OF | | ACCEPTANCE TO INDICATE COMPLIANCE WITH THE | | REQUIREMENTS OF ONE OF THE | | FOLLOWING SPECIFICATIONS: | | | | ANSI/AAMA/NWWDA 101/I.S.2-97 OR TAS 202 | | (HVHZ SHALL COMPLY WITH TAS 202) | | | | 2) WITH VISITING THE JOBSITE TO VERIFY THE TYPE OF | | GLASS AND THICKNESS TWO MORE CONCERNS WERE NOTICED. 2A) | | ON THE FOURTH FLOOR WE NOTICED A MULLION BETWEEN TWO | | SEPERATE SLIDING GLASS DOORS. THERE IS NO PRODUCT | | APPROVALS SUBMITTED FOR STRUCTURAL MULLIONS. PLEASE | | PROVIDE PRODUCT APPROVALS FOR THE STRUCTURAL MULLION. | | | | 2B) WITH VISITING THE JOBSITE IN EACH UNITS VISITED, | | THE SLIDING GLASS DOOR TRACK WAS APPROXIMATELY 41/2" | | ABOVE THE CONCRETEFLOOR. IN RETURNING TO THE BUILDING | | DEPARTMENT | | I REVIEWED THE CITY SEET OF REVIEWED PLANS FOR | | THIS TYPE OF DETAIL, SHEET A440 DETAIL # 6 PROVIDED THE | | DETAIL THAT WS REVIEWED TO THE FAIR HOUSING STANDARDS. | | I ALSO DISCUSSED THIS ISSUE WITH BO NEIL MELICK WHICH | | HE ALSO INDICATED ALL UNITS ARE TO COMPLY WITH THE FAIR | | HOUSING STANDARDS FOR SLIDING GLASS DOORS USED AS A | | SECONDARY ENTRANCE. | | A COPY OF THIS STANDARDIS ATTACHED. | | | | 3) THE SAME ISSUE AS (1A)IS THE TYPE OF LAMINATION | | USED FOR THE SINGLE HUNG WINDOWS, THERE IS NO WAY OF | | KNOWING WHAT TYPE OF LAMINATION WAS USED. | | THE ONE WAY THAT WE CAN IDENTIFY WHAT TYPE OF UNITS | | WERE SHIPPED IS BY PROVIDING A COPY OF THE BILL OF | | LADING, THIS MAY IDENTIFY THE AMOUNT OF WINDOWS AND | | DOORS | | THAT WERE SHIPPED TO THE JOB SITE? | | | | 4) NOTE: JOBSITE INSPECTION OF THE LOBBY ENTRY DOORS, | | YES THE PRODUCT APPROVAL FOR SIGNATURE DOORS DOES | | INCLUDE LARGE MISSLE TESTING NOA 04-0211.09 | | DOORS DO NOT HAVE ANY APPROVAL LABELS. | | 1707.4.2.1 TESTING AND LABELING. EXTERIOR WINDOWS AND | | GLASS DOORS | | SHALL BE TESTED BY AN APPROVED INDEPENDENT TESTING | | LABORATORY, AND | | SHALL BE LABELED WITH AN APPROVED LABEL IDENTIFYING | | THE MANUFACTURER, | | PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT | | CERTIFICATION AGENCY, | | TESTING LABORATORY, EVALUATION ENTITY OR MIAMI-DADE | | NOTICE OF | | ACCEPTANCE TO INDICATE COMPLIANCE WITH THE | | REQUIREMENTS OF ONE OF THE | | FOLLOWING SPECIFICATIONS: | | ANSI/AAMA/NWWDA 101/I.S.2-97 OR TAS 202 | | (HVHZ SHALL COMPLY WITH TAS 202) | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
14 |
Status |
F |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-04-03 |
Time |
11:51 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2007-04-03 |
Time |
11:51 |
Sent To |
PC |
|
Notes |
2007-04-03 11:54:54 | BUILDING PLAN REVIEW | | PERMIT: 04110183 | | ADD: 3900 N FLAGLER BLDG# 1 | | CONT: THE WEITZ CO. | | TEL: (561)329-9079 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | THIS IS A THRESHOLD BUILDING REQUIRING (3) OF ALL | | DOCUMENTS BEING SUBMITTED TO THE CITY. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
13 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-03-16 |
Time |
15:22 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2007-03-16 |
Time |
15:22 |
Sent To |
PC |
|
Notes |
2007-03-16 15:23:08 | WALL FRAMING & CALCS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
12 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-03-16 |
Time |
14:26 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2007-03-16 |
Time |
14:26 |
Sent To |
PC |
|
Notes |
2007-03-16 14:27:43 | REV# 7 16'-0" OVERHEAD GARAGE DOOR |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
11 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-09-15 |
Time |
09:32 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2006-09-15 |
Time |
09:32 |
Sent To |
PC |
|
Notes |
2006-09-15 00:00:00 | BLDG# 1 SUBMITTAL TRASH CHUTE- OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
F |
Date |
2006-05-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-05-02 |
Time |
14:12 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2006-05-02 |
Time |
14:12 |
Sent To |
PC |
|
Notes |
2006-05-02 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04110182 | | 04110183 | | 04110184 | | 04110185 | | ADD:3900 N FLAGLER DR | | CONT:THE WEITZ CO | | TEL: (561)719-6724 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVISION: | | ACTION:DENIED | | | | SUBMITTAL FOR THE FOLLOWING: | | REVISION GARAGE DOOR: OVERHEAD GARAGE | | DOOR, 16'-0" SERIES 180 SECTIONAL DOOR | | | | THE MIAMI-DADE NOA SUBMITTED IS FOR A | | 16'-0" WIDE OPENING, SERIES 180. THE | | LETTER OF APPROVAL FROM THE ARCHITECTS | | IS FOR A SERIES 188, SIZE 10'-0"X8'-3", | | THEY DO NOT MATCH. THE NOA MENTIONED IN | | THE LETTER HAS EXPIRED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
F |
Date |
2006-01-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-01-26 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-01-26 |
Time |
12:00 |
Sent To |
|
|
Notes |
2006-01-26 00:00:00 | ****CORRECTIONS**** | | WINDOW SHOP DRAWINGS | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.)THIS WAS SUBMITTED AS SHOP | | DRAWINGS.THE PRODUCTS YOU ARE USING | | ARE NOT THE SAME PRODUCTS AS THE | | APPROVED PERMIT PACKAGE.THIS IS A | | REVISION, REQUIRING REVIEW.A REVISION | | FEE HAS BEEN ADDED.WHEN RESUBMITTING, | | PLEASE SUBMIT AS A REVISION. | | | | 2.)FLORIDA STATE OR LOCAL PRODUCT | | APPROVAL REQUIRED, FAC9B72, SB442. | | | | 3.)EXPIRED NOAS SUBMITTED.PLEASE | | NOTE THAT THE EXPIRED NOAS BY THEMSELVES | | CANNOT BE USED TO SHOW CODE COMPLIANCE | | IF APPLYING FOR LOCAL PRODUCT APPROVAL. | | | | 4.)FBC1601.2.1, THERE IS NO PROVISION | | IN THE CODE FOR A 1% WIND OVERSTRESS AS | | SHOWN FOR THE SMALL MISSILE IMPACT | | SINGLE HUNG WINDOWS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
F |
Date |
2005-12-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-12-16 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-12-16 |
Time |
17:23 |
Sent To |
|
|
Notes |
2005-12-16 00:00:00 | ****CORRECTIONS**** | | TRUSS SUBMITTAL, BLDG 1 | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.)THE TRUSS PLACEMENT HAS AN INK SEAL | | RATHER THAN AN EMBOSSED SEAL. | | FAC61G15-23.002, DOCUMENTS PREPARED BY | | AN ENGINEER ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2005-12-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-12-16 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-12-16 |
Time |
17:15 |
Sent To |
|
|
Notes |
2005-12-16 00:00:00 | ****CORRECTIONS**** | | | | SUBMITTALS; TENDON AND SUPPORT SHOPS AND | | CALCS | | | | BLDG 1, LEVELS 3 & 4 | | BLDG 1, ROOF | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | 1.)A TITLE BLOCK IS REQUIRED, | | FAC61G15-23.003.MR. HAMID'S ADDRESS ON | | DBPE WEBSITE IS NOT THE ADDRESS ON THE | | PLAN, WHICH APPEARS TO BE FOR PTE.IF | | PTE IS PRACTICING ENGINEERING AND MR. | | HAMID IS THE INDIVIDUAL WHO IS SEALING | | THE DOCUMENT THROUGH THE COMPANY, THE | | INFORMATION FOR PTE SERVES AS THE TITLE | | BLOCK AND IS REQUIRED TO HAVE THE | | CERTIFICATE OF AUTHORIZATION FOR THE | | FIRM PRINTED ON THE PLAN.IF MR. HAMID | | IS SEALING THE PLAN INDIVIDUALLY, HIS | | TITLE BLOCK WITH ALL INFORMATION | | REQUIRED BY FAC61G15-23.002 IS REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2005-12-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-12-16 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-12-16 |
Time |
17:09 |
Sent To |
|
|
Notes |
2005-12-16 00:00:00 | SUBMITTALS | | | | STUD RAIL SHOPS | | | | SHORING/RESHORE LETTERS | | BLDG 1 ROOF SHORING/3RD AND 4TH FL | | RESHORE | | BLDG 1 4TH FL SHORING/2ND & 3RD FL | | RESHORE |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2005-08-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-08-28 |
Time |
10:24 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2005-08-28 |
Time |
10:24 |
Sent To |
PC |
|
Notes |
2005-08-28 00:00:00 | 8-28-05 SUBMITTALS: | | SHORING SHOP DRAWINGS | | RESHORE SHOP DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2005-07-31 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-07-31 |
Time |
16:33 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2005-07-31 |
Time |
16:33 |
Sent To |
B |
|
Notes |
2005-07-31 00:00:00 | SHORING & RESHORING AND LETTERSJW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-05-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-05-03 |
Time |
13:08 |
Rev Time |
3.33 |
Received By |
jwitmer |
Date |
2005-05-03 |
Time |
13:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-02-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-02-11 |
Time |
11:28 |
Rev Time |
5.50 |
Received By |
jwitmer |
Date |
2005-02-11 |
Time |
11:28 |
Sent To |
|
|
Notes |
2005-02-11 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04110183 | | ADD: 3900 N FLAGLER DR. BLDG# 1 | | CONT: MANHATTEN CONSTRUCTION | | TEL: (813)927-0209 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 1) COMMENT #1 FROM THE PREVIOUS REVIEW, | | PROVIDE NOC RECORDED WITH THE CLERK OF | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | 2) COMMENT #7 FROM THE PREVIOUS REVIEW, | | A202, DEALS WITH LISTING THE DOOR RATING | | IN EITHER MINUTES OR HRS. THE HEADING OF | | THIS COLULM STILL INDICATE DOOR "LABEL" | | THE SECOND ISSUE IS THE BUILDINGS | | WITH THE DOORS OF THE TERMINATION ROOM | | THAT ARE ON THE EXTERIOR OF THE BUILDING | | | | HAVE NO RATING. SEE TABLE 705.1.2. | | | | 3) COMMENT #8 FROM THE PREVIOUS REVIEW, | | TRASH CHUTE A503 IS TO INDICATE A 2HR | | RATING THROUGH TO THE UNDERSIDE OF THE | | ROOF SHEATHING,THE RATING IS MISSING | | AT THE BOTTOM OF THE TRUSSES, SEE | | 705.2.3.4.2. | | | | 4) COMMENT #17 FROM THE PREVIOUS REVIEW, | | A502 PROVIDE INFO FOR ACCESS HATCH, | | HATCH DOES NOT NEED TO BE 2 HR RATING | | SINCE IT IS NO LONGER PART OF THE SHAFT. | | | | 5)COMMENT # 23 FROM THE PREVIOUS REVIEW, | | 1503.4.2 OVERFLOW DRAINS SHALL BE THE | | SAME SIZE AS ROOF DRAINS, INSTALLED WITH | | THE INLET FLOW LINE LOCATED 2" ABOVE THE | | LOWEST POINT OF THE ROOF LINE. OVERFLOW | | SCUPPERS SHALL BE A MINIMUM OF 4"IN | | HEIGTH AND SHALL BE PLACED IN WALLS OR | | PARARETS WITH THE INLET FLOW LINE | | NOT LESS THAN 2" ABOVE THE ROOF SURFACE. | | THE EMERGENCY OVERFLOW DRAIN IS | | INDICATED ON THE "P" SHEETS BUT THE | | HEIGHT FROM THE ROOF LINE IS NOT | | INDICATED, IT COULD BE 6" ABOVE THE ROOF | | DRAIN. THE INTENT IS NOT TO HAVE OVER 4" | | | | OF WATER ON THE ROOF. WITH THE SLOPED | | ROOF SYSTEM IF THE EMERGENCY DRAIN IS | | LEVEL WITH THE ROOF LINE YOU WILL HAVE A | | MAXIMUM OF 4"OF WATER AT THE ROOF | | DRAIN. | | | | 6)COMMENT #24 FROM THE PREVIOUS REVIEW, | | 1503.4.4 PROTECTION AGAINST DECAY & | | TERMITES. CONDENSATE LINES & ROOF DOWN | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | AWAY FROM THE STRUCTURE SIDEWALL, | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | TENSIONS, OR SPLASH BLOCKS. | | THE PLUMBING PAGES SHOW COMPLIANCE | | WITH SPLASH BLOCKS FOR DOWN SPOUTS, BUT | | THE MECHANICAL DOESN'T INDICATE | | COMPLIANCE FOR CONDENSATE DRAINS. | | | | 7)COMMENT #25 FROM THE PREVIOUS REVIEW, | | BUILDING # 1 SHOWS COMPLIANCE, BUT THE | | OTHER BUILDINGS DO NOT HAVE ANYNOTES | | OR DETAIL INDICATING COMPLIANCE. | | 1511.7 ROOF MOUNTED MECHANICAL UNIT | | S SHALL BE MOUNTED ON CURBS RAISED A | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | EQUIPMENT, APPLIANCES AND SUP PORTS THAT | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | AND INSTALLED TO RESIST THE WIND | | PRESSURES ON THE EQUIPMENT & THE | | SUPPORTS AS DETERMINED IN ACCORDANCE | | WITH THE FL BLD CODE. THIS MAY BE ACCOMP | | LISHED BY DESIGN OR BY APPLICATION OF | | SECTION 301.13.1. | | | | 8)COMMENT #26 MEAN ROOF HEIGHT IS ABOVE | | 35', THE WEST PALM AMENDMENTS ARE GOOD | | TO 35', ENGINEER TO INDICATE NAILING | | PATTERNS FOR ABOVE 35'. TABLE 2306.1* | | | | 9)COMMENT #27 FROM THE PREVIOUS REVIEW, | | THE STRUCTURAL PLANS DO NOT PROVIDE A | | ROOF FRAMING PLAN WITH THE TRUSSES | | IDENTIED, NOR THE LOADS TO BE IMPOSED, | | UPLIFT, GRAVITY NOR F1OR F2. THE ROOF | | TRUSSES ARE PART OF THE MAIN WIND FORCE | | RESISTING SYSTEM FOR THE STRUCTURE. | | THESE LOADS NEED TO BE IDENTIFIED TO | | ALLOW FOR THE CORRECT ANCHORS TO BE | | EMBEDDED INTO THE CONCRETE POUR. SEE | | FBC 1606.2.4 | | | | 10)COMMENT # 28 FROM THE PREVIOUS REVIEW | | THERE IS NO ANCHOR SCHEDULE IDENTIFYING | | THE MANUFACTURER, MODEL NUMBER, AND THE | | ALLOWABLE LOADSFOR ANCHORS THAT ARE | | PRINTED IN THE MANUFACTURERS 2005 | | CATALOG. | | | | 11)COMMENT #28C) FROM THE PREVIOUS | | REVIEW, SHEAT S9-1 "SEE LATEST SIMPSON | | CATALOG FOR FASTENER REQUIREMENTS | | CORRESPONDING TO SIMSON CONNECTORS | | SPECIFIED. THE DESIGN PROFESSIONAL | | HASN,T GIVEN ANY VALUES FOR UPLIFT OR | | OTHER VALUES OF RESISTANCE. NOR HAS THE | | DESIGN PROFESSIONAL PROVIDED A ANCHOR | | SCHEDULE INDICATING WHAT VALUES THAT | | THEY PREFER TO USE.104.2.1 W.P.B. | | ADMINISTRATIVE CODE DRAWINGS & | | SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR | | OTHERWISE, AS TO THE QUALITY OF | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. | | SUCH INFORMATION SHALL BE SPECIFIC | | AND THE TECHNICAL CODES "SHALL NOT BE | | CITED AS A WHOLE OR IN PART, NOR THE | | TERM "LEGAL" OR ITS RQUIVALENT BE USED | | AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". | | | | 12) COMMENT #29A) FROM THE PREVIOUS | | REVIEW. A-451 DETAIL #4, THE ATTACHMENT | | OF THE FOAM BRAKET,PLANS DO NOT | | PROVIDE WHAT TYPE OF ATTACHMENT METHOD | | TO BE USED OR QUANITITY OF FASTENERS. | | | | 13) COMMENT #30 FROM THE PREVIOUS REVIEW | | A442 DETAIL #8, THE BAHAMA SHUTTER IS TO | | BE ATTACHED TO A 2X_, THE SHUTTER | | PRODUCT APPROVAL PROVIDES FASTENERS FOR | | THE SHUTTER BUT THE DETAIL LACKS HOW | | THE FRAMING MEMBER IS ATTACHED TO THE | | STRUCTURE. FASTENER, SIZE & SPACING. | | | | 14) COMMENT #32 FROM THE PEVIOUS REVIEW, | | PROVIDE UNITITY OF TITLE FOR LOTS: | | 74-43-43-09-01-000-0110 | | 74-43-43-09-01-000-0090 | | | | 15) COMMENT #31 FROM THE PEVIOUS REVIEW, | | BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | THESE COMMENTS MAY OR MAY NOT PERTAIN TO | | BUILDING #1 SINCE THE PLANS HAVE ALL | | BUILDINGS COMBINED, OTHER COMMENTS MAY | | APPEAR THAT WERE NOT PART OF THE | | PREVIOUS REVIEW SINCE ALL BUILDINGS ARE | | INCORPORATED INTO ONE PLAN. PLEASE BREAK | | THE MEP INTO A SINGLE UNIT, PLANS ARE TO | | CUMBERSOME TO REVIEW AS IS, | | | | *********NOTE*******NOT ALL ROLLS OF | | PLANS ARE COMPLETE,SOME ARE MISSING | | THE STRUCTURAL PAGES TOTALLY. | | | | *********NOTE******PRODUCT APPROVALS (3) | | SETS OF PRODUCT APPROVALS WILL BE | | REQUIRED FOR PROJECT. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-12-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-12-08 |
Time |
11:37 |
Rev Time |
3.33 |
Received By |
jwitmer |
Date |
2004-12-08 |
Time |
09:02 |
Sent To |
|
|
Notes |
2004-12-08 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04110183 | | ADD: 3900 N FLAGLER**BLDG# 1** | | CONT: MANHATTEN CONSTRUCTION | | TEL: (813)927-0209 | | CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | 2) FBC* 105.3RESIDENT INSPECTOR. | | SUBMIT INSPECTOR RESUME' AND LICENSE | | DOCUMENTS TO HAROLD PISKURA, DIRECTOR | | OF | | THE RESIDENT INSPECTOR PROGRAM.A | | RESIDENT INSPECTOR PROGRAM IS REQUIRED, | | ON THIS PROJECT, DUE TO ONE OR MORE OF | | THE FOLLOWING: | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | CONSTRUCTION | | - ANY MAJOR STRUCTURAL ALTERATIONS | | - STRUCTURES IN WHICH THE CONCRETE | | DESIGN IS BASED ON COMPRESSIVE | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | - PILE DRIVING | | - BUILDINGS OVER 20,000 SQFT IN AREA | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | - BUILDING/STRUCTURES OF UNUSUAL | | DESIGN | | OR METHODS OF CONSTRUCTION | | | | 3)THE FINISHED FLOOR LEVEL SHALL BE | | VERIFIED BY A SIGNED AND SEALED | | ELEVATION CERTIFICATE. SITE IS LOCATED | | IN A (A5) FLOOD ZONE, THE MINIMUM | | FINISH | | SLAB MUST BE 7.5' NGVD. | | | | 4) FL BLD CODE 1804.2.2 QUESTIONABLE | | SOILS, WHERE THE BEARING CAPACITY IS | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | WHERE THE BEARING CAPACITY OF THE SOIL | | IS NOT DEFINITLY KNOWN OR IS IN | | QUESTION | | THE BUILDING OFFICIAL MAY REQUIRE | | EXPLOR | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | TO THE PERMISSIBLE SAFE BEARING | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | NICALREPORT FROM A DESIGN PROFESSIONAL | | PROPERLY LICENSED IN THE STATE OF | | FLORIDA. | | | | 5) PLANS INDICATE THE USE OF AUGER | | PILE, | | THE SOILS ENGINEER TO PROVIDE | | INFORMATION AS TO WHAT THEY WIL BE | | INSPECTING, GROUT, SPACING DEPTH ETC | | SEE | | REQUIREMENTS IN SECTION 1809.2 FOR | | AUGERED PILE. | | | | 6) PLANS ARE CUMBERSOME, OR UNWIELDY | | TRYING TO REVIEW 6 BUILDINGS IN ONE SET | | OF PLANS. WITH THE NUMBER OF PAGES AND | | DETAILS IT IS DIFFICULT TO TURN TOO, | | LOCATE AND REFRENCE THE VARIOUS | | DETAILS. | | THIS MAY CREATE ADDITIONALCOMMENTS | | THAT AREN'T ADDRESSED ON THE FIRST | | REVIEW, AT BEST BREAK OUT THE VARIOUS | | TRADES UNTIL A PERMIT SET OF PLANS IS | | APPROVED AND READY FOR PERMIT. | | | | 7) A202 LIST VARIOUS DOORS AS EITHER | | "B" OR "C" LABELED DOORS, SEE TABLE | | 705.1.2 THAT LIST THE DOOR RATING IN | | EITHER MINUTES OR HOURS. | | | | 8) TRASH CHUTE- S8-4 DETAILS AA & BB | | BOTH HAVE THE @ HR RATED SHAFT STOPPING | | SHORT OF THE PLYWOOD ROOF SHEATHING.SEE | | 705.2.3.4.2. | | | | 9) F101 TYPICAL FLOORS 2-4 ARE MISSING | | THE FIRE SPRINKLER AT THE TOPAND | | ALTERNATING FLOORS LEVELS AND | | TERMINATION ROOM. 705.2.4.6 | | | | 10) S8-6, A442 & A464 VARIOUS DETAILS | | INDICATE THE USE OF 5/8" EXTERIOR | | SHEATHING? NO MENTION AS TO MATERIAL, | | TYPE V BUILDING. | | | | 11) A.442 VARIOUS DETAILS INDICATE THE | | USE OF 6" METAL STUDS FOR EXTERIOIR | | FRAMING. WITHOUT THE WALL ASSEMBLY | | DESCRIPTION ABOVE UNABLE TO DETERMINE | | TABLE 2213.1A./ 2213.1B. | | | | 12)FL BLD CODE CHAP 13 ENERGY EFFICENCY | | PROVIDE ENERGY CALS/ W MANUAL "J" | | | | 13) FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, A106 | | THE ELEVATOR LOBBY DOORS ARE NOT | | NUMBERED NOR THE FRONT ENTRY DOORS TO | | THE UNIT DO NOT HAVE FIRE RATINGS SEE | | TABLE 705.1.2. | | | | 14) A.501 DETAILS INDICATE A 1/2" | | HANDRAIL SEE 1007.5.3. | | | | 15) FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, A502 | | INDICATES A DETAIL OF THE ELEVATOR | | SHAFT | | 3003.1.8 A METAL OR CONCRETE FLOOR | | SHALL | | BE PROVIDED AT THE TOP OF ALL | | HOISTWAYS. | | INDICATECODE COMPLIANCE, IF SO THEN | | PROVIDE THE DETAIL FOR THE 2 HR RATED | | CEILING. | | | | 16) A502 INDICATES THE ELEVATOR VENTING | | BUT SIZE IS NOT GIVEN PROVIDE: | | 3003.6.3 THE AREA OF THE VENTS SHALL | | BE | | NOT LESS THAN 3 SQ FT FOR EACH ELEVATOR | | CAR, WHICHEVER IS GREATER. | | | | 17) A502 PROVIDE REPORT FOR THE 2HR | | RATED ACCESS HATCH. | | | | 18) A503 INDICATES THE USE OF WOOD | | TRUSSES BUT NO INFORMATION PROVIDE FOR | | SOFFIT ATTIC VENTING? 2309.7. | | | | 19) 301.13.1 GROUND MOUNTED A/C UNITS: | | GROUND-MOUNTED UNITS FOR R3 RESIDENTIAL | | APPLICATIONS MAY BE ANCHORED WITH # 14 | | SCREWS WITH GASKETED WASHERS ACCORDING | | TO THE FOLLOWING: | | 1) FOR UNITS WITH SIDES LESS THAN 12", | | ONE SCREW SHALL BE USED AT EACH SIDE OF | | THE UNIT. | | 2) FOR UNITS BETWEEN 12" & 24", TWO | | SCREWS SHALL BE USED PER DIDE. | | 3) FOR UNITS BETWEEN 24" & 36", THREE | | SCREWS SHALL BE USED PER SIDE. | | 4) FOR UNITS GREATER THAN 36" OR 5 | | TONS | | ANCHORAGE SHALL BE DESIGN IN ACCORDANCE | | WITH 301.13. (140 MPH). | | | | 20)1606.1.4(1) IN WIND BORNE DEBRIS | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | ASSUMED TO BE OPENINGS UNLESS SUCH | | GLAZING IS IMPACT RESISTANT OR | | PROTECTED | | WITH AN IMPACT RESISTANT COVERING MEET- | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | 1) GLAZED OPENINGS LOCATED WITHIN 30 | | FT | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | LARGE MISSLE TEST. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, | | 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR | | INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | FL BLD CODE 1606.1.5: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORTS,MISSING REPORTS ARE AS | | FOLLOWS: | | A) WINDOWS FIXED & OPERTABLE | | B)DOORS, SWING, SLIDING AND OVERHEAD | | C) MULLIONS | | D)LOUVERS | | E) EXTERIOR RAILINGS | | F) STORM SHUTTERS | | G) TRUSS ANCHORS | | H) EXTERIOR RAILINGS | | I) ROOFING ASSEMBLIES/ FLAT & PITCHED | | ROOFS | | J)SOFFIT- POLYBEAD | | | | 21)1707.4.5.1 MULLIONS OCCURRING | | BETWEEN | | INDIVIDUAL WINDOW AND GLASS | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | REQUIRED BY AN APPROVED TESTING | | LABORATORY OR BE ENGINEERED. | | | | 22) 1707.4.5.2 MULLIONS SHALL BE | | DESIGN- | | ED TO TRANSFER THE DESIGN PRESSURE | | LOADS | | APPLIED BY THE WINDOW OR DOOR | | ASSEMBLIES | | TO THE ROUGH OPENING SUBTRATE. | | | | 23)1503.4.2 OVERFLOW DRAINS SHALL BE | | THE | | SAME SIZE AS ROOF DRAINS, INSTALLED | | WITH | | THE INLET FLOW LINE LOCATED 2" ABOVE | | THE | | LOWEST POINT OF THE ROOF LINE. OVERFLOW | | SCUPPERS SHALL BE A MINIMUM OF 4"IN | | HEIGTH AND SHALL BE PLACED IN WALLS OR | | PARARETS WITH THE INLET FLOW LINE | | NOT LESS THAN 2" ABOVE THE ROOF | | SURFACE. | | | | 24) 1503.4.4 PROTECTION AGAINST DECAY & | | TERMITES. CONDENSATE LINES & ROOF DOWN | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | AWAY FROM THE STRUCTURE SIDEWALL, | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | TENSIONS, OR SPLASH BLOCKS. | | | | 25)1511.7 ROOF MOUNTED MECHANICAL UNITS | | SHALL BE MOUNTED ON CURBS RAISED A | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | EQUIPMENT, APPLIANCES AND SUP PORTS | | THAT | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | AND INSTALLED TO RESIST THE WIND | | PRESSURES ON THE EQUIPMENT & THE | | SUPPORTS AS DETERMINED IN ACCORDANCE | | WITH THE FL BLD CODE. THIS MAY BE | | ACCOMP | | LISHED BY DESIGN OR BY APPLICATION OF | | SECTION 301.13.1. | | | | 26) MEAN ROOF HEIGHT IS ABOVE 35' THE | | WEST PALM NAILING AMENDMENTS ARE GOOD | | TO | | A ROOF HEIGHT OF 35'. | | ENGINEER TO PROVIDE THE ADDITIONAL | | NAILING FOR THE ROOF ZONES 1,2&3. | | | | TABLE 2306.1 PALM BEACH COUNTY | | AMENDMENTS | | ROOF SHEATHING NAILING REQUIREMENTS | | | | ZONE 1 & 28D COMMON | | 6" EDGES & 6" INTERMEDIATES | | | | ZONE 38DCOMMON | | 4" EDGES & 6" INTERMEDIATES | | PROVIDE THE NAILING REQUIREMENTS FOR | | ZONES 1,2&3 FOR ROOF AREAS OVER 35'. | | | | 27) THE STRUCTURAL PLANS DO NOT PROVIDE | | A ROOF FRAMING PLAN WITH THE TRUSSES | | IDENTIFIED, NOR THE LOADS IDENTIFIED, | | UPLIFT, GRAVITY NOR F1,F2. THE ROOF | | TRUSSES ARE PART OF THE MAIN FORCE | | RESISTING SYSTEM AND SO ALL ELEMENTS OF | | THE TRUSS PACKAGE SYSTEM NEED TO BE | | ENGINEERED. SEE 1606.2.4. | | | | 28) THERE IS NO TRUSS ANCHOR SCHEDULE | | IDENTIFYING THE MANUFACTURER MODEL | | NUMBER OF ANCHOR OR VALUE THE TRUSS | | ANCHOR CAN BE LOADED TO. SEE | | 28A)1707.3.1 JOIST HANGERS, FRAMING | | ANCHORS & SIMILAR DEVICES SHALL BE | | TEST- | | ED IN ACCORDANCE W/ ASTM D 1761 & BE | | LABELED AND LISTED FOR THEIR LOAD | | CARRY- | | ING CAPACITY. | | | | 28B)1609.4.3 LOAD REDUCTION. | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | MORE LOADS IN COMBINATION WITH DEAD | | LOAD | | ARE INVESTIGATED IN LOAD COMBINATIONS | | OF | | 1609.4.1 OR 1609.4.2, THE COMBINED | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | LOADS SHALL NOT BE LESS THAN THE | | EFFECTS | | FROM THE LOAD COMBINATION OF THE DEAD | | LOAD PLUS THE LOAD PRODUCING THE | | LARGEST | | EFFECTS. INCREAS IN ALLOWABLE STRESS | | SPE | | CIFIED IN THE MATERIALS SECTIONS OF | | THIS | | CODE OR A REFRENCED STANDARD SHALL NOT | | BE USED WITH THESE LOAD COMBINATIONS | | EXCEPT THAT A DURATION OF LOAD INCREASE | | SHALL BE PERMITTED IN ACCORDANCE WITH | | CHAPTER 23. | | 28C) THE COMMENT ON S9-1 "SEE LATEST | | SIMSON CATALOG FOR FASTENER | | REQUIREMENTS | | CORRESPONDING TO SIMSON CONNECTOR | | SPECIFIED. PLEASE EXPLAIN COMMENT. | | 104.2.1 W.P.B. ADMINISTRATIVE CODE | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR | | OTHERWISE, AS TO THE QUALITY OF | | MATERIALS, WHERE QUALITY IS ESSENTIAL | | TO | | CONFORMITY WITH THE TECHNICAL CODES. | | SUCH INFORMATION SHALL BE SPECIFIC | | AND | | THE TECHNICAL CODES "SHALL NOT BE CITED | | AS A WHOLE OR IN PART, NOR THE TERM | | "LEGAL" OR ITS RQUIVALENT BE USED AS A | | SUBSTITUTE FOR SPECIFIC INFORMATION". | | | | 29) FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | A-451 DETAIL 4 PROVIDE THE FOLLOWING: | | A) ATTACHMENT OF THE FOAM BRAKET | | B) ATTACHMENT OF THE RIGID INSULATION | | | | BOARD | | C) 5/8 GYPSUM SOFFIT BOARD: ADDITIONAL | | | | INFORMATION ON PRODUCT? | | | | 30) A442 DETAIL# 8 WINDOW HEADER W/ | | BAHAMA SHUTTER PROVIDE ADDITIONAL | | INFORMATION, THE FASTENERS ARE LOCATED | | WITHIN 3/4" OF THE CONCRETE FACE, WILL | | THERE BE A REDUCTION IN LOADING FOR | | THIS | | FASTENING SYSTEM? | | | | 31) BEFORE A PERMIT TO CONSTRUCT, MAY | | BE | | ISSUED, IMPACT FEES MUST BE PAID TO | | PALM | | BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 32) PROVIDE A UNITY OF TITLE FOR LOTS: | | 74-43-43-09-01-000-0110 | | 74-43-43-09-01-000-0090 | | TABLE 600 ISSUES MAY ARISE OTHERWISE. | | | | 33) TABLE 500 ISSUES, TYPE "V" | | UNPROTECTED ONLY ALLOWS 2 STORIES, TO | | CLAIM THE HEIGHT OF A (4) STORY BUILDING | | TABLE 500 FOOTNOTE "J" AND 903.2 WILL | | REQUIRE A FULL NFPA 13 FIRE SPRINKLER | | SYSTEM. THE ONLY EXCEPTION IS 503.2.2 | | FOR TYPE I, II | | OR TYPEIII. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL | | LETTER | | LISTING THE ORIGINAL REVIEW COMMENT | | NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR | | SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE | | FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
13 |
Status |
P |
Date |
2007-02-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2007-02-12 |
Time |
16:23 |
Rev Time |
1.00 |
Received By |
jleahy |
Date |
2007-02-12 |
Time |
16:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
12 |
Status |
P |
Date |
2006-12-22 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-12-22 |
Time |
06:42 |
Rev Time |
0.45 |
Received By |
jleahy |
Date |
2006-12-22 |
Time |
06:42 |
Sent To |
|
|
Notes |
2006-12-22 06:42:59 | PAGE E-501 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
11 |
Status |
P |
Date |
2006-12-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-12-07 |
Time |
06:30 |
Rev Time |
1.00 |
Received By |
jleahy |
Date |
2006-12-07 |
Time |
06:29 |
Sent To |
|
|
Notes |
2006-12-07 06:30:13 | REVISION 10,11, E302,303,304,203,201,501,502,503 | | | | NEED TO VERIFY SIZE OF FIRE PUMP CONTROLERS, BATH | | FIXTURES TO BE INSTALLED PER 210.70A |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
10 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-10-31 |
Time |
16:21 |
Rev Time |
1.00 |
Received By |
jleahy |
Date |
2006-10-31 |
Time |
16:21 |
Sent To |
|
|
Notes |
2006-10-31 16:21:02 | NEED SIZE OF CONTROLLERS NOT SHOWN ON DRAWINGS | 2006-10-20 07:09:29 | ELECTRICAL RISER/ REVISIONS GIVEN TO JAKE LEAHY FOR | | REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
9 |
Status |
P |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-16 |
Time |
20:10 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-16 |
Time |
20:10 |
Sent To |
FIRE |
|
Notes |
2006-06-16 00:00:00 | REV FOR UNIT LAYOUT FOR BLDG #1 OK, | | STAMPED, ROUTED TO FIRE FOR REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
N |
Date |
2006-06-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-02 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-02 |
Time |
07:43 |
Sent To |
|
|
Notes |
2006-06-02 00:00:00 | PLANS CONTAIN NO ELEC REV'S, YET COVER | | SHEET WAS CHECKED FOR ELECTRICAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-05-17 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-05-17 |
Time |
07:44 |
Sent To |
|
|
Notes |
2006-05-17 00:00:00 | ******** UNSAT ********* | | | | | | 1) NOTE: PLEASE SEE COMMENTS FROM | | PREVIOUS REVIEW AS THE SD'S ARE STILL | | SHOWN BEING WIRED TO MORE THAN ONE | | CIRCUIT IN A SINGLE UNIT?? | | PLEASE KNOW, THE SD'S ARE REQUIRED TO | | WIRED "INLINE", WHICH AS SHOWN ON | | MULTIPLE CIRCUITS IS NOT PERMITTED. | | THESE MAY BE WIRED TO THE ARC FAULT | | PROTECTED BEDRM CIRCUIT, HOWEVEER THESE | | CAN ONLY BE ON ONE CIRCUIT. | | NFPA-72 8-1.4.1.6.2, | | | | 2) NOTE: PLEASE SEE SEC'S HAVE NOW BEEN | | DOWN SIZED TO 3/0'S FOR ONE FIRE PUMP | | SERVICE, AND 4/0'S FOR THE OTHER. | | PLEASE SEE THAT THE SEC'S SHALL ME SIZED | | ACCORDINGLY TO THE OCP, HP, AND THE SIZE | | OF THE FPC. | | PLEASE SEE 310.16, AS 3/0'S ARE ONLY | | RATED AT 200A'S AND THE 4/0'S ARE ONLY | | RATED FOR 225A'S. PLEASE SEE | | 240.4,310.16. | | THE OCP SHOWN ON MAIN IS 250A'S. | | (LOOCKED ROTOR SHOULD BE SET AND PART OF | | THE FPC AND MUST BE 6X THE FLA'S. | | 695.4/695.5 | | | | ** NOTE ** | | PLEASE KNOW, IT HAS COME TO THE | | ATTENTION OF THIS OFFICE THAT SOME OF | | THE SLIDING GLASS DOORS ON PLANS ARE | | ACTUALLY "FIXED GLASS PANELS" PLEASE SEE | | 210.52 AS "FIXED GLASS" IS CONSIDERED | | WALL SPACE. | | PLEASE SEE PLANS IN MANY PLACES STILL | | INDICATE MANY OF THESE AS SLIDING GLASS | | DOORS?? AS REVIEWED ON PREVIOUS PLANS. | | ANY INSTALLATION OF FIXED GLASS PANELS, | | WILL BE VERIFIED IN THE FIELD AND PLANS | | SHALL BE REVISED ACCORDING TO ACTUAL | | WALL SPACE CONSTRUCTED. | | | | | | PLEASE REVISE AND SUBMIT THE ABOVE | | INFORMATION FOR REVIEW. IF THERE ARE ANY | | QUESTIONS, PLEASE DO NOT HESITATE IN | | CONTACTING THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
N |
Date |
2006-01-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-23 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-23 |
Time |
15:07 |
Sent To |
M |
|
Notes |
2006-01-23 00:00:00 | SUBMITTIAL FOR DRY-IN OF BLDG,NOT FOR | | ELEC REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
N |
Date |
2005-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-30 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-30 |
Time |
15:08 |
Sent To |
|
|
Notes |
2005-12-30 00:00:00 | APPLIANCE SUBMITTIALS NOT NEED FOR | | REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2005-12-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-09 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-09 |
Time |
15:38 |
Sent To |
|
|
Notes |
2005-12-09 00:00:00 | ****** UNSAT ******* | | | | 1)NOTE: PLEASE SEE NOTE ON ALL PLANS | | INDICATE SD'S ARE TO BE WIRED TO | | HALL/FOYER CIRCUITS, HOWEVER CIRCUITING | | ON PLANS WAS NOT CHANGED. | | PLEASE BE SURE THAT IF THESE SD'S ARE | | NOW GOING TO CHANGE TO HALL/FOYER LTS, | | THEN THESE CIRCUITS WILL ALSO NOW BE | | REQUIRED TO BE ARC FAULT.210.12 | | PLEASE ALSO SEE CIRCUITING FOR SD'S HAS | | GONE BACK TO THE SD'S OF THE SAME UNIT | | BEING WIRED TO MORE THAN ONE CIRCUIT. | | SMOKE DETECTORS ARE REQUIRED TO BE WIRED | | INLINE AND THIS WILL NOT WORK ON MORE | | THAN ONE CIRCUIT. | | PLEASE ADJUST ALL CIRCUITING. | | | | 2)NOTE: PLEASE SEE FIRE PUMP | | FEEDERS/SEC'S FROM THE FPL TRANSFORMER | | TO THE METER AND FROM THE METER TO THE | | FIRST MEANS OF DISCONNECT IS NOTED AS | | HAVING AN EQUIPMENT GROUNDING CONDUCTOR. | | PLEASE REVISE SCHEDULE. | | THESE ARE ONLY INSTALLED AFTER THE FIRST | | MEANS OF DISCONNECT. | | | | 3)NOTE: PLEASE SEE 302 WHICH DOES NOT | | INDICATE ANY REVISONS, HOWEVER TITLE | | BLOCK DOES INDICATE THIS. | | | | 4)NOTE: PLEASE SEE 620.23 A SEPARATE | | BRANCH CIRCUIT SHALL SUPPLY THE MACHINE | | ROOM OR CONTROL ROOM/MACHINERY SPACE OR | | CONTROL SPACE LIGHTING AND | | RECEPTACLE(S). | | | | PLEASE MAKE THE ABOVE CORRECTIONS AND | | SUBMIT FOR REVIEW. IF THERE ARE ANY | | QUESTIONS, PLEASE DO NOT HESITATE IN | | CONTACTING THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-25 |
Time |
18:26 |
Rev Time |
4.00 |
Received By |
dpalmer |
Date |
2005-04-25 |
Time |
18:26 |
Sent To |
|
|
Notes |
2005-04-25 00:00:00 | **REDLINED ** | | | | 1) NO EQUIPMENT GROUNDING CONDUCTORS | | FROM TRANSFORMER TO METER OR METER TO | | FIRST MEANS OF DISCONNECT. | | 250.6,250.24 | | EQUIPMENT GROUNDING CONDUCTORS SHOWN TO | | FIRE PUMP SHALL NOT BE INSTALLED. | | | | ALL 12 ROLLS STAMPED FOR ELECTRICAL. | | NO REVISION NEEDED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-02-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-14 |
Time |
09:52 |
Rev Time |
1.50 |
Received By |
dpalmer |
Date |
2005-02-14 |
Time |
09:52 |
Sent To |
|
|
Notes |
2005-02-14 00:00:00 | *** NOTES *** | | THIS IS FOR BLDGS: 1,2,5 AND 6. | | THIS COMMENT DOES NOT AFFECT BLDGS: 3 OR | | 4. | | | | 1)NOTE:PLEASE SEE NFPA-20 IN REFERENCE | | TO FIRE PUMP ELECTRICAL SERVICE | | LOCATION. | | PLEASE SEE SERVICE SHALL BE LOCATED AS | | NOT TO BE AFFECTED IN CASE OF FIRE / | | EXPLOSION ETC WITH MAIN ELECTRICAL | | SERVICE. | | THIS FIRE PUMP SERVICE SHOULD STILL BE | | LOCATED IN CLOSE PROXIMITY TO MAIN | | ELECTRICAL RM. | | PLEASE SEE NFPA-20, 6.2.1 | | 6-2.1 SERVICE. | | WHERE POWER IS SUPPLIED BY A SERVICE, IT | | SHALL BE LOCATED AND ARRANGED TO | | MINIMIZE THE POSSIBILITY OF DAMAGE BY | | FIRE FROM WITHIN THE PREMISES AND | | EXPOSING HAZARDS. | | NFPA-70 695 | | THE CONNECTION SHALL BE LOCATED AND | | ARRANGED SO AS TO MINIMIZE THE | | POSSIBILITY OF DAMAGE BY FIRE FROM | | WITHIN THE PREMISES AND FROM EXPOSING | | HAZARDS. | | MOST IMPORTANT IN 695.3(A)(2) IS THE | | REQUIREMENT THAT A FIRE IN ONE SOURCE | | NOT AFFECT THE RELIABILITY OF ANOTHER | | SOURCE. | | | | THIS WAS NOT IN ORIGINAL REVIEW NOTES. | | | | PLEASE MAKE THE ABOVE CHANGES AND SUBMIT | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CONTACTING. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-12-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-12-01 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2004-11-23 |
Time |
15:46 |
Sent To |
|
|
Notes |
2004-12-01 00:00:00 | PLEASE SEE NOTES UNDER 04110182 | 2004-11-30 00:00:00 | NOTES TO FOLLOW |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
N |
Date |
2005-02-23 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2005-02-23 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
mamini |
Date |
2005-02-23 |
Time |
11:18 |
Sent To |
|
|
Notes |
2005-02-23 00:00:00 | N: | | | | 1. SEE PERMIT# 05021226 FOR | | UNDERGROUND UTILITIES AND SITE WORK. | | THIS PERMIT INCLUDES BUILDING PADS | | PREPARATION FOR ALL BUILDINGS. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2004-11-15 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2004-11-15 |
Time |
15:46 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2004-11-15 |
Time |
15:47 |
Sent To |
|
|
Notes |
2004-11-15 00:00:00 | PASSED WITH PROVISOS: | | 1. EROSION AND SEDIMENTATION CONTROL | | DEVICES SHALL BE IN PLACE PRIOR TO | | BEGINNING CLEARING OR GRUBBING, | | DEMOLITION, OR OTHER SUCH CONSTRUCTION | | ACTIVITIES. THE DEVICES SHALL BE | | INSTALLED, MONITORED, AND MAINTAINED IN | | ACCORDANCE WITH ALL APPLICABLE FEDERAL, | | STATE, AND LOCAL REQUIREMENTS. | | | | 2. WORK WITHIN PUBLIC R.O.W REQUIRES A | | PERMIT FROM PUBLIC UTILITIES AND | | ENGINEERING, PLEASE SUBMIT M.O.T PLANS | | ALSO AT THE TIME OF APPLICATION ATT: | | WINDEL PALMER, 494-1086. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
N |
Date |
2006-06-08 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-06-08 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-06-08 |
Time |
14:01 |
Sent To |
|
|
Notes |
2006-06-08 00:00:00 | REVISION DATED 2/13/06 | | | | NO NEW COMMENTS SINCE LAST FIRE REVIEW. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
N |
Date |
2006-01-26 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2006-01-26 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2006-01-26 |
Time |
12:31 |
Sent To |
I |
|
Notes |
2006-01-26 00:00:00 | PLEASE SEE NOTES UNDER PERMIT # 04110182 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2005-12-13 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-12-13 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-12-13 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-02-28 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-02-28 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-12-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-12-31 |
Time |
09:23 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2004-12-31 |
Time |
09:23 |
Sent To |
|
|
Notes |
2004-12-31 00:00:00 | SEE COMMENTS ON PERMIT 04110184 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
36 |
Status |
N |
Date |
2007-05-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-05-21 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-05-21 |
Time |
16:30 |
Sent To |
B |
|
Notes |
2007-05-21 16:30:51 | TO "JWITMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
35 |
Status |
N |
Date |
2007-04-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-16 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-16 |
Time |
14:21 |
Sent To |
B |
|
Notes |
2007-04-16 14:22:18 | TO "JWITMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
34 |
Status |
N |
Date |
2007-03-26 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-03-26 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-03-26 |
Time |
18:28 |
Sent To |
B |
|
Notes |
2007-03-26 18:28:18 | TO JIM WITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
33 |
Status |
N |
Date |
2006-12-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-18 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-18 |
Time |
10:09 |
Sent To |
E |
|
Notes |
2006-12-18 10:09:37 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
32 |
Status |
N |
Date |
2006-10-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-10 |
Time |
17:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-10 |
Time |
17:58 |
Sent To |
E |
|
Notes |
2006-10-10 17:59:08 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
31 |
Status |
N |
Date |
2006-07-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-19 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-19 |
Time |
09:54 |
Sent To |
FIRE |
|
Notes |
2006-07-19 00:00:00 | TO "F" BOX/REV | | 7/19/06--CONTRACTOR PULLED PLANS FROM | | REVIEW PROCESS--SEE FRONT SCREEN NOTE. | | ADARROUGH | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
30 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-26 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-26 |
Time |
10:29 |
Sent To |
M |
|
Notes |
2006-06-26 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
29 |
Status |
N |
Date |
2006-06-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-09 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-09 |
Time |
08:46 |
Sent To |
E |
|
Notes |
2006-06-09 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
28 |
Status |
N |
Date |
2006-06-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-02 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-02 |
Time |
16:48 |
Sent To |
M |
|
Notes |
2006-06-02 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
27 |
Status |
N |
Date |
2006-05-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-04 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-04 |
Time |
10:34 |
Sent To |
|
|
Notes |
2006-05-24 00:00:00 | TO "COMM" BD#64-3 REV'S |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
26 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-04 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-04 |
Time |
13:47 |
Sent To |
|
|
Notes |
2006-05-05 00:00:00 | TO "COMM" BD#48-3 REV'S | 2006-05-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
25 |
Status |
N |
Date |
2006-04-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-21 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-21 |
Time |
12:04 |
Sent To |
B |
|
Notes |
2006-04-21 00:00:00 | TO "JWITMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
24 |
Status |
N |
Date |
2006-04-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-21 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-21 |
Time |
11:52 |
Sent To |
B |
|
Notes |
2006-04-21 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
23 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-14 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-14 |
Time |
11:05 |
Sent To |
|
|
Notes |
2006-04-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
22 |
Status |
N |
Date |
2006-01-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-26 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-26 |
Time |
13:32 |
Sent To |
B |
|
Notes |
2006-01-26 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
21 |
Status |
N |
Date |
2006-01-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-18 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-18 |
Time |
14:43 |
Sent To |
E |
|
Notes |
2006-01-18 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
20 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-29 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-29 |
Time |
16:49 |
Sent To |
E |
|
Notes |
2005-12-29 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
19 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-29 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-29 |
Time |
16:02 |
Sent To |
FIRE |
|
Notes |
2005-12-29 00:00:00 | TO "F" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
18 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-29 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-29 |
Time |
15:54 |
Sent To |
B |
|
Notes |
2005-12-29 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
17 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-29 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-29 |
Time |
15:51 |
Sent To |
B |
|
Notes |
2005-12-29 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
16 |
Status |
N |
Date |
2005-11-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-23 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-23 |
Time |
16:25 |
Sent To |
B |
|
Notes |
2005-11-23 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-16 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-16 |
Time |
16:05 |
Sent To |
M |
|
Notes |
2005-11-16 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-15 |
Time |
18:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-15 |
Time |
18:26 |
Sent To |
B |
|
Notes |
2005-11-15 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2005-10-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-13 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-13 |
Time |
16:14 |
Sent To |
E |
|
Notes |
2005-10-13 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-05 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-05 |
Time |
11:13 |
Sent To |
B |
|
Notes |
2005-10-05 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2005-09-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-19 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-19 |
Time |
15:31 |
Sent To |
|
|
Notes |
2005-09-22 00:00:00 | TO "COMM" BD#1/PLANS ON RACK/4 ROLLS | 2005-09-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2005-09-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-08 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-08 |
Time |
18:02 |
Sent To |
B |
|
Notes |
2005-09-08 00:00:00 | TO "JWITMER" DESK/4 SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-09 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-09 |
Time |
09:51 |
Sent To |
B |
|
Notes |
2005-08-09 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-08-02 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-08-02 |
Time |
10:14 |
Sent To |
B |
|
Notes |
2005-08-02 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-07-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-29 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-29 |
Time |
16:44 |
Sent To |
B |
|
Notes |
2005-07-29 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-07-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-26 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-26 |
Time |
15:00 |
Sent To |
B |
|
Notes |
2005-07-26 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-06-08 |
Time |
08:11 |
Sent To |
ENG |
|
Notes |
2005-06-08 00:00:00 | TO 'MAMINI' DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-05-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-12 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-12 |
Time |
13:59 |
Sent To |
B |
|
Notes |
2005-05-12 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-01-26 |
|
|
Cont ID |
|
Sent By |
ptjomsto |
Date |
2005-01-26 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
ptjomsto |
Date |
2005-01-26 |
Time |
15:00 |
Sent To |
|
|
Notes |
2005-01-26 00:00:00 | SUBMITTAL GIVEN TO NEIL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-01-20 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-20 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-20 |
Time |
11:05 |
Sent To |
|
|
Notes |
2005-01-20 00:00:00 | TO "COMM BD#61/RESUB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-12-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-12-31 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2004-11-05 |
Time |
10:44 |
Sent To |
|
|
Notes |
2004-11-05 00:00:00 | TO COMM BD# |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
9 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-03-08 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-03-08 |
Time |
08:21 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
8 |
Status |
P |
Date |
2006-06-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-06-29 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-06-29 |
Time |
08:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
F |
Date |
2006-06-20 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-06-20 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-06-20 |
Time |
10:06 |
Sent To |
|
|
Notes |
2006-06-20 00:00:00 | PLEASE PROVIDE ENERGY CALCULATIONS AND | | MANUAL J WITH REVISIONS. | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-06-16 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-06-16 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2006-06-05 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-05 |
Time |
14:33 |
Rev Time |
1.00 |
Received By |
tgordon |
Date |
2006-06-05 |
Time |
14:33 |
Sent To |
|
|
Notes |
2006-06-05 00:00:00 | MECH. REVISION TO PAGE M-201. | | *** PROVISO *** | | 1) FLOOR DRAINS ARE NOT PERMITTED IN | | OPEN RETURN AIR PLENUMS, PER 2001 FBC/P | | 901.2, AND FBC/M 601.3 . | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2006-01-04 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-01-04 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-01-04 |
Time |
15:39 |
Sent To |
|
|
Notes |
2006-01-04 00:00:00 | DENIED: PERMIT 04110183 | | PLANS INDICATE VE FOR VARIOUS AHU'S TO A | | LESSER TONNAGE/BTU'S.ENERGY &MANUAL | | J CALCULATIONS HAVE NOT BEEN REVISED. | | PLEASE CLARIFY MANUFACTURER REQUIREMENT | | FOR SIZING OF THE LINE SETS. | | | | PLANS INDICATE THE FOLLOWING CHANGES: | | PLAN SHEET M-201 UNIT A1 | | AHU-1 (2 TON) REPLACING AHU-2 (2.5 TON) | | AHU-5 (4 TON) REPLACING AHU-6 (5 TON) | | | | PLAN SHEET M203 UNIT C2 | | AHU-1 (2 TON) REPLACING AHU-2 (2.5 TON) | | AHU-2 (2.5 TON) REPLACING AHU-3 (3 TON) | | | | PLAN SHEET M205 UNIT C3 | | AHU-4 (3.5 TON) REPLACING AHU-5 (4 TON) | | AHU-7 (1.5 TON ) REPLACING AHU-1 (2 TON) | | | | PLAN SHEET M206 UNIT A4 | | AHU-1 (2 TON) REPLACING AHU-2 (2.5 TON) | | AHU-5 (4 TON) REPLACING AHU-6 (5 TON) | | | | PLAN SHEET M208UNITS E5 & D-5 | | AHU-1 (2 TON) REPLACING AHU-2 (2.5 TON) | | AHU-3 (3 TON) REPLACING AHU-4 (3.5 TON) | | AHU-7 (1.5 TON)REPLACING AHU-1(2 TON) | | | | PLAN SHEET M210 UNITS F6, E6, & D6 | | AHU-1 (2 TON) REPLACING AHU-2 (2.5 TON) | | AHU-3 (3 TON) REPLACING AHU-4 (3.5 TON) | | AHU-7 (1.5 TON) REPLACING AHU-1 (2 TON) | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2005-05-20 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-05-20 |
Time |
13:24 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2005-05-20 |
Time |
13:24 |
Sent To |
|
|
Notes |
2005-05-20 00:00:00 | PROVISO: | | SYSTEMS THAT HAVE THE DESIGN CAPACITY (5 | | TON & LARGER), GRATER THAN 2,000 CFM | | SHALL HAVE FANSHUT DOWN BY DUCT SMOKE | | DETECTOR OR THE SYSTEM IS PROTECTED BY | | AREA SMOKE DETECTORS IN ACCORDANCE WITH | | 2001 FBC/M 606.4. | | | | DRYERS ARE TO BE INSATLLED FOR FINAL | | INSPECTION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2005-02-17 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-02-17 |
Time |
10:20 |
Rev Time |
4.00 |
Received By |
pkrauss |
Date |
2005-02-17 |
Time |
10:20 |
Sent To |
|
|
Notes |
2005-02-17 00:00:00 | DENIED:BUILDING #1 | | 1.AS PER CONVERSATION WITH JIM | | MULLENS, DRYER SUBMITTAL TO BE CHANGED | | AND THE PLANS WILL BE REVISED DELETING | | THE BOOSTER FANS INSTALLED IN THE DRYER | | EXHAUST DUCT.SPECIFIC DRYERS ARE TO BE | | INSTALLED BY FINAL INSPECTION. | | | | 2.PLAN SHEET M203 THE TRASH CHUTE ROOM | | DOES NOT INIDCATE A CO SENSOR AS | | REQUIRED PER PREVIOUS REVIEW. | | | | 3.PLEASE NOTE, IN THE RESIDENTIAL | | UNITS AS WELL AS COMMON AREAS, SYSTEMS | | THAT HAVE THE DESIGN CAPACITY TO PRODUCE | | GREATER THAN 2,000 CFM, DUCT SMOKE | | DETECTORS WILL BE REQUIRED IN THE SUPPLY | | AIR DUCT.AS AN ALTERNATE TO THE DUCT | | SMOKE DETECTOR, UPON ACTIVATION OF AN | | AREA DUCT SMOKE DETECTOR, THE A/C UNIT | | WILL SHUT DOWN.2001 FBC(M) 606.2.1, | | 606.2.2 AND 606.4. | | | | 4.FAN SHUTDOWN SHALL HAVE NOTIFICATION | | PER 2001 FBC(M)606.4.1. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-12-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-12-31 |
Time |
09:22 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-12-31 |
Time |
09:02 |
Sent To |
|
|
Notes |
2004-12-31 00:00:00 | SEE COMMENTS ON PERMIT 04110182 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
F |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-06-19 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-06-19 |
Time |
14:38 |
Sent To |
|
|
Notes |
2006-06-19 00:00:00 | DENIED | | REFERENCD: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | REVISION DENIED, SHTS P206, P208, 9210, | | & P211 SHALL BE SUBMITTED UNDER THE | | CORRECT PERMIT NUMBER. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-06-19 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-06-19 |
Time |
10:34 |
Sent To |
|
|
Notes |
2006-06-19 00:00:00 | REVISION OK - SHEETS P208 & P310. P310 | | APPROVAL ONLY FOR RISERS CONCERNING THIS | | REVISION THIS PERMIT. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-11-15 |
Time |
17:42 |
Rev Time |
4.25 |
Received By |
kstevens |
Date |
2005-11-14 |
Time |
19:06 |
Sent To |
|
|
Notes |
2005-11-15 00:00:00 | REVISION DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1. SHTS P203, P205, P206, P207, P208, | | P209, 7 P210 SHALL BE SUBMITTED FOR | | REVISION UNDER THE APPROPRIATE PERMIT | | NUMBER FOR THOSE SHEETS. SECTION | | 104.2.1. | | 2. SHTS P205 & 209 REVISION REQUIRED FOR | | THE ARCHITECTURAL SHEETS SHOWING THE | | DELETION OF THE SCUPPERS. SEE COMMENT #1 | | FROM LAST REVISION SUBMITTAL (6-23-5). | | 3. SHT P210 LEVEL 2-4. LEVEL 2 IS | | DIFFERENT THAN LEVELS 3 & 4. REVISE | | SEPARATELY. INDICATE UNIT DESIGNATION ON | | EACH SHEET. SECTION 104.2.1. | | - E6 OPP. REVISION REQUIRED FOR THE | | FLOOR PLAN. ONLY E6 FLOOR PLAN HAS BEEN | | REVISIED. IF FLOOR PLAN NOT REVISED, | | SUBMIT A RISER DIAGRAM TO REFLECT | | UNCHANGED FLOOR PLAN. SECTION 104.3.1.1. | | - G6 TUB NOT VENTED. WHAT RISER HAS BEEN | | REVISED TO REFLECT THIS CHANGE? | | - H6 INDICATE RISER NUMBER TO REFLECT | | CHANGE. | | - K6 2ND FLOOR INDICATE RISERS FOR | | THESE CHANGES. | | - F6 3RD & 4TH FLOORS | | 4. SHT P301 WHERE IS WATER HEATER DRAIN | | PAN - WASTE WATER DETAIL? HAVE THE WATER | | HEATERS BEEN DELETED? DETAIL TO BE SHOWN | | ON REVISION. | | - WHERE IS RISERS SAN/6 & SAN/9? THESE | | ARE STILL SHOWN ON THE FLOOR PLANS. | | - SAN/7 DOES NOT REFLECT THE FLOOR | | PLAN. | | - UNIT B-2 MASTER BATH SANT FITTINGS | | SHALL BE INSTALLED TO GUIDE SEWAGE AND | | WASTE IN THE DIRECTION OF FLOW. SECTION | | 706.3. | | - UNIT E-5/6 MASTER BATH, SHOW ALL PIPE | | SIZES. MAX 4FU ON 2" WET VENT. SECTION | | 104.2.1 AND TABLE 909.3. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2005-05-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-05-14 |
Time |
18:44 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2005-05-14 |
Time |
18:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2005-02-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-02-09 |
Time |
10:27 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2005-02-09 |
Time |
10:27 |
Sent To |
|
|
Notes |
2005-02-09 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | A) FROM PREVIOUS REVIEW: | | 1) A TITLE BLOCK MUST CONTAIN THE | | FOLLOWING INFORMATION. | | 61G1-16.004(2)(6) | | THE FIRM LICENSE NUMBER, AND THE | | PRINTED | | NAME OF THE PERSON SEALING THE | | DOCUMENT. | | ALSO THE CERTIFICATE OF AUTHORIZATION | | OF | | THE FIRM. SEE SHEETS L1 THRU L6 AND | | SHEETS I-1 THRU I-3. | | **************NEW COMMENT************* | | 1B) SHT P202 BUILDING 1 STORM RISER | | DIAGRAM. MAXIMUM 730 SF @ 1% SLOPE. 4" | | PIPE REQUIRED ON THE HORIZONTAL PIPING | | OR INDICATE 4% SLOPE. INDICATE ON | | PLANS. | | TABLE 1106.3. | | 2B) SHT P202 SCUPPERS THRU THE MANSARD | | ROOF REQUIRES A MINIMUM OF 21.195 SQ IN | | 6" PIPE IS REQUIRED. TABLE 1106.3 AND | | SECTION 1107.3. | | 3B) SHT P204 MINIMUM 4" PIPE REQUIRED | | ON | | STORM RISER HORIZONTAL PIPING. TABLE | | 1106.3. | | 4B) SHT P204 MINIMUM 6" PIPE REQUIRED | | ON | | THE SCUPPER DRAINS. SECTION 1107.3 | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-12-08 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-12-08 |
Time |
18:18 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2004-12-08 |
Time |
18:18 |
Sent To |
|
|
Notes |
2004-12-08 00:00:00 | DENIED | | | | SEE COMMENTS FROM PERMIT #04110182 | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2005-05-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-05-13 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-05-13 |
Time |
13:12 |
Sent To |
B |
|
Notes |
2005-05-13 00:00:00 | APPROVED BY GRACE JOYCE, PLANNER | | 822-1435. RETURNED TO JIM W DESK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2005-05-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-05-06 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-05-06 |
Time |
11:23 |
Sent To |
|
|
Notes |
2005-05-06 00:00:00 | DENIED, | | 1. APPLIED FOR AMENDMENT | | 2. AMENDMENT NOT APPROVED. | | | | GRACE JOYCE, PLANNER | | 822-1435 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-01-20 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-01-20 |
Time |
15:12 |
Sent To |
|
|
Notes |
2005-01-20 00:00:00 | DENIED, MUST APPLY FOR A MINOR AMENDEND | | TO THE CHANGES THAT ARE BEING MADE. | | APPLICATION WILL BE IN ON MONDAY | | 1/24/05. | | | | CALL GRACE JOYCE, PLANNER 822-1447 IF | | YOU HAVE ANY QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-12-21 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-12-21 |
Time |
09:01 |
Sent To |
|
|
Notes |
2004-12-21 00:00:00 | THE ELEVATIONS OF BUILDING 1 ARE NOT THE | | SAME AS THE APPROVED SITE PLAN.THE | | APPROVED BUILDING HEIGHT OF 48' IS NOT | | SHOWN ON THE PLAN. | | IN ORDER TO CHANGE BUILDING ELEVATIONS | | (FOR ALL OR JUST ONE) A MINOR AMENDMENT | | IS REQUIRED |
|
|