Plan Review Details - Permit 04110122
Plan Review Stops For Permit 04110122
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-01-07 Cont ID  
Sent By lsmith Date 2005-01-07 Time 16:25 Rev Time 0.50
Received By lsmith Date 2005-01-07 Time 16:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-11-23 Cont ID  
Sent By lsmith Date 2004-11-23 Time 13:05 Rev Time 1.00
Received By lsmith Date 2004-11-23 Time 13:05 Sent To  
Notes
2004-11-23 00:00:00BUILDING PLAN REVIEW:
  
 ACCORDING TO MARSHALL & SWIFT COST OF
 THE POOL HAS BEEN ADJUSTED TO 30490.
 ADDITIONAL FEES OF $241.69 ARE DUE
 BEFORE PERMITING.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-01-07 Cont ID  
Sent By dpalmer Date 2005-01-07 Time 15:36 Rev Time 0.25
Received By dpalmer Date 2005-01-07 Time 15:36 Sent To B
Notes
2005-01-07 00:00:00**** PROVSIO *****
  
 1)NOTE: PLEASE REVISE RISER DIAGRAM W/
 LOAD CALCS AND OPTIONS BEFORE FINAL.
 RISER/ LOAD CALCS SHEET REMOVED AS IT
 DID NOT CORRELATE WITH OTHER SUBMITTED
 LOAD CALCS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-11-12 Cont ID  
Sent By dpalmer Date 2004-11-12 Time 17:27 Rev Time 0.25
Received By dpalmer Date 2004-11-12 Time 17:27 Sent To P
Notes
2004-11-12 00:00:00********** UNSAT ****************
  
 1)NOTE: PLEASE CORRELATE PANEL SCHEDULE
 /LOAD CALCULATIONS WITH ALL EQUIPMENT
 SHOWN ON ELECTRICAL RISER DIAGRAM FOR
 POOL EQUIPMENT.
 BLOWER SHOWN AS OPTIONAL?
  
 2)NOTE: PLEASE SEE ALL CONTINUOUS LOADS
 ARE TO BE SHOWN AT 125%/ PUMP/
 HEAT-PUMP. 215.3,230.42 ETC.
 PLEASE SEE LOAD IS SHOWN MAXED AT 70A'S
 ALREADY.
 PLEASE ALSO INCLUDE LOAD CALCULATIONS
 FOR EXISTING SERVICE INCLUDING NEW
 LOADS
 BEING ADDED.220.31B
  
 3)NOTE: PLEASE SEE FBC 104.2.1, WHICH
 REQUIRES THE PRINTED NAME AND SIGNATURE
 OF PERSON RESPONSIBLE FOR PLANS.
  
 THE ABOVE NOTES ARE NOT FOR THE PLANS
 SUBMITTED DONE BY ENGINEER.
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW SHEETS INTO COMPLETE
 SETS FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-05 Cont ID  
Sent By mjacobs Date 2005-01-05 Time 09:20 Rev Time 0.00
Received By mjacobs Date 2005-01-05 Time 09:20 Sent To E
Notes
2005-01-05 00:00:00TO "DP" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 16:03 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 16:03 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-11-02 Cont ID  
Sent By csiegber Date 2004-11-02 Time 12:31 Rev Time 0.00
Received By csiegber Date 2004-11-02 Time 12:31 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-11-23 Cont ID  
Sent By kstevens Date 2004-11-23 Time 09:58 Rev Time 0.50
Received By kstevens Date 2004-11-23 Time 09:58 Sent To B1
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-11-12 Cont ID  
Sent By mmclean Date 2004-11-12 Time 12:32 Rev Time 0.00
Received By mmclean Date 2004-11-12 Time 12:32 Sent To I
Notes
2004-11-12 00:00:00NOTE: DECK MUST BE A MIN OF 3FT AND POOL
 MUST BE A MIN OF 5FT