Plan Review Details - Permit 04100673
Plan Review Stops For Permit 04100673
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-12-21 Cont ID  
Sent By alange Date 2004-12-21 Time 10:32 Rev Time 1.00
Received By alange Date 2004-12-21 Time 10:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-12-20 Cont ID  
Sent By alange Date 2004-12-20 Time 08:51 Rev Time 1.00
Received By alange Date 2004-12-20 Time 08:51 Sent To  
Notes
2004-12-20 00:00:00DENIED
  
 2.SUBMIT SECOND COPY OF PRODUCT
 APPROVALS FOR STRAPS AND TIE DOWNS.
  
  
 I INSERTED THE STATE APPROVALS AND
 ATTACHJED THEM TO THE MIAMI-DADE
 APPROVALS.K.D. WINDOWS WAS NOT
 LISTED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-11-30 Cont ID  
Sent By alange Date 2004-11-30 Time 13:44 Rev Time 1.25
Received By alange Date 2004-11-30 Time 13:44 Sent To  
Notes
2004-11-30 00:00:00DENIED
  
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR STRAPS AND TIEDOWNS.
 ALL PRODUCT APPROVALS REQUIRE THE
 FOLLOWING TO BE ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3.SHOW METHOD OF SLAB TIE-IN FROM
 EXISTING TO NEW SLAB.
  
 4.FBC 1816 TERMITE PROTECTION
 REQUIRED
 SHOW ON PLANS.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-11-05 Cont ID  
Sent By btrobaug Date 2004-11-05 Time 17:44 Rev Time 0.50
Received By btrobaug Date 2004-11-05 Time 17:35 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-03 Cont ID  
Sent By mjacobs Date 2004-12-03 Time 16:26 Rev Time 0.00
Received By mjacobs Date 2004-12-03 Time 16:26 Sent To P
Notes
2004-12-03 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-05 Cont ID  
Sent By csiegber Date 2004-11-05 Time 11:24 Rev Time 0.00
Received By csiegber Date 2004-11-05 Time 11:24 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-27 Cont ID  
Sent By csiegber Date 2004-10-27 Time 15:01 Rev Time 0.00
Received By csiegber Date 2004-10-27 Time 15:01 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-11-15 Cont ID  
Sent By pkrauss Date 2004-11-15 Time 14:33 Rev Time 0.15
Received By pkrauss Date 2004-11-15 Time 14:00 Sent To P
Notes
2004-11-15 00:00:00NO MECHANICAL PLANS OR CONTRACTOR
 INDICATED WITH PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS @ (561)805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-12-16 Cont ID  
Sent By kstevens Date 2004-12-16 Time 14:01 Rev Time 0.45
Received By kstevens Date 2004-12-16 Time 14:01 Sent To B1
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-22 Cont ID  
Sent By mjacobs Date 2004-12-03 Time 16:27 Rev Time 0.25
Received By kstevens Date 2004-11-22 Time 10:50 Sent To B1
Notes
2004-11-22 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
  
 1) SHT 8 SANITARY RISER DIAGRAM DOES NOT
 MEET CODE REQUIREMENTS.
 A) THE WASH MACHINE SHALL NOT DRAIN
 THROUGH THE WET VENT FOR THE BATHROOM
 FIXTURES. THE WASH MACHINE SHALL
 DISCHARGE DOWNSTREAM OF THE BATHROOM
 FIXTURES. SECTION 909.1 - SECTION
 104.2.1.
 B) WASH MACHINE IS REQUIRED TO HAVE A
 STANDPIPE. SECTION 1002.1
  
  
 (SEE RED LINE EXAMPLE OF CORRECT PIPING
 ON SHT 8 OF ONE SET OF PLANS)
  
  
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-11-04 Cont ID  
Sent By csiegber Date 2004-11-04 Time 15:01 Rev Time 0.00
Received By mmclean Date 2004-11-04 Time 12:07 Sent To I
Notes
***NONE***