Plan Review Details - Permit 04100617
Plan Review Stops For Permit 04100617
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-01-06 Cont ID  
Sent By jwitmer Date 2005-01-06 Time 16:02 Rev Time 0.55
Received By jwitmer Date 2005-01-06 Time 16:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-12-07 Cont ID  
Sent By jwitmer Date 2004-12-07 Time 10:50 Rev Time 0.55
Received By jwitmer Date 2004-12-02 Time 10:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-10-29 Cont ID  
Sent By jwitmer Date 2004-10-29 Time 07:15 Rev Time 1.11
Received By jwitmer Date 2004-10-29 Time 07:10 Sent To  
Notes
2004-10-29 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04100617
 ADD: 1822 UPLAND RD
 CONT: BAINES
 TEL: (561)718-3997
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 SEE BBC DESIGNS IN THE TITLEBLOCK, IN-
 CLUDE REQUIRED LICENSE NUMBERS FOR ARCH
 AND INTERIOR DESIGNERS. FAC 16.004,
 61G15-23 FOR ENGINEERS.
  
 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 3) KITCHEN ENTRY PULL SIDE OF DOOR:
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL. PULL SIDE OF DOOR 18"
 MINIMUM.
  
 4)1012.1.4. DURING ITS SWING, ANY
 DOOR IN A MEANS OF EGRESS SHALL LEAVE
 UNOBSTRUCTED AT LEAST 1/2 OF THE REQUIRE
 REQUIRED WIDTH OF AN AISLE, CORRIDOR,
 PASSAGEWAY, OR LANDING, NOR PROJECT MORE
 THAN 7" INTO THE REQUIRED WIDTH.FOR LESS
 THAN 50 OCCUPANTS A MINIMUM OF 36" CORRI
 DOR IS REQUIRED, MINIMUM CLEAR AISLE
 WIDTH OF 18" WITH DOOR OPEN 90 DEGREES
 TO THE DOOR JAMB, SEE H/C RESTROOM.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-12-30 Cont ID  
Sent By dpalmer Date 2004-12-27 Time 08:37 Rev Time 0.33
Received By dpalmer Date 2004-12-27 Time 11:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-11-18 Cont ID  
Sent By dpalmer Date 2004-11-18 Time 19:37 Rev Time 0.33
Received By dpalmer Date 2004-11-18 Time 19:32 Sent To  
Notes
2004-11-18 00:00:00*********** UNSAT ***********
  
 ***PLEASE SEE PACKAGE DID NOT COME BACK
 WITH ORIGINAL PERMIT APPLICATION ?? ***
  
 1)NOTE: PLEASE CORRELATE A/C HEAT LOAD
 WITH MECH PLANS.
 ONE SHOWS 10KW AND THE OTHER 8KW?
  
 2)NOTE: PLEASE SEE 700.12E FOR
 CIRCUITING OF EM LTS. SHOWN ON W/ OFFICE
 LTS.
  
 3)NOTE: PLEASE SEE MISSING RECEPT FOR
 ROOFTOP A/C 210.63 GFI
  
 4)NOTE: PLEASE SEE PLANS ARE NOT
 PERMITTED TO HAVE ANY HANDWRITTEN
 CHANGES OR ADDITIONS TO PLANS WHICH ARE
 SIGNED, DATED AND SEALED BY AN
 ENGINEER.
 FS 471.025
  
 ** PLEASE SEE TITLE BLOCK MENTIONS TED
 BERGUS CONTRACTOR, YET PERMIT
 APPLICATION IS FOR BAINES BLDG??
  
 PLEASE SEE POSSIBLE COMMENTS FROM OTHER
 REVIEWER(S) WHICH MAY AFFECT ELECTRICAL
 PLANS.
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-10-23 Cont ID  
Sent By dpalmer Date 2004-10-23 Time 07:35 Rev Time 0.33
Received By dpalmer Date 2004-10-23 Time 07:35 Sent To  
Notes
2004-10-23 00:00:00****** UNSAT *******
  
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS. THERE ARE A COUPLE OF ITEMS NOT
 IDENTIFIED.
 PLEASE ALSO SEE 700.12E FOR CIRCUITING
 OF EM/EXT LTS. SOME SHOWN ON WITH
 GARAGE OUTLETS?
 PLEASE SEE POSSIBLE FIRE REVIEW COMMENTS
 FOR PLACEMENT OF EXIT SIGNS.NOTE ONLY:
  
 2)NOTE: PLEASE SEE CIRCUITING FOR RECEPT
 'S. PLEASE SEE 220.13 FOR 180VA PER
 DEVICE. PLEASE SEE # OF RECEPTS ON
 CIRCUITS WHICH SEEM TO OVERLOAD CIRCUIT-
 -S.MAX 1920 FOR A 20A CIR.
  
 3)NOTE: PLEASE SEE BBC DESIGNS IN TITLE
 BLOCK. PLEASE INCLUDE REQUIRED LICENSE
 #'S ? PER FS 481. ARCH/INT DESIGN.
 PLEASE ALSO SEE FAC 61G1-16.004,
 61G15-23.002 FOR ENGINEER.
 PLEASE SEE MISSING PRINTED NAME AND #.
 FBC 104.2.1
  
 PLEASE SEE POSSIBLE NOTES FROM OTHER
 REVIEWER(S) WHICH MAY AFFECT ELECTRICAL
 PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2004-12-15 Cont ID  
Sent By mcarsill Date 2004-11-05 Time 14:12 Rev Time 0.00
Received By mcarsill Date 2004-12-15 Time 09:55 Sent To  
Notes
2004-11-05 00:00:001) VEHICLES STORED IN BUILDING
 SHALL HAVE THE BATTERIES DISCONNECTED.
  
 2) DOOR SWINGS TO FAR INTO CORRIDOR.
 PLEASE REVISE PLANS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-20 Cont ID  
Sent By mjacobs Date 2004-12-20 Time 11:13 Rev Time 0.00
Received By mjacobs Date 2004-12-20 Time 11:13 Sent To  
Notes
2004-12-20 00:00:00SENT TO "COMM BD#49

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-15 Cont ID  
Sent By csiegber Date 2004-11-15 Time 08:45 Rev Time 0.00
Received By csiegber Date 2004-11-15 Time 08:45 Sent To  
Notes
2004-11-15 00:00:00TO COMM BD#

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-11-06 Cont ID  
Sent By kstevens Date 2004-11-06 Time 08:21 Rev Time 0.00
Received By kstevens Date 2004-10-18 Time 15:22 Sent To  
Notes
2004-10-18 00:00:00TO COMM BD#28

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-12-31 Cont ID  
Sent By pkrauss Date 2004-12-31 Time 10:12 Rev Time 0.40
Received By pkrauss Date 2004-12-31 Time 10:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-12-04 Cont ID  
Sent By pkrauss Date 2004-12-04 Time 09:25 Rev Time 0.35
Received By pkrauss Date 2004-12-04 Time 08:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-11-04 Cont ID  
Sent By pkrauss Date 2004-11-04 Time 14:56 Rev Time 0.40
Received By pkrauss Date 2004-11-04 Time 14:09 Sent To  
Notes
2004-11-04 00:00:00DENIED:
 1.PLEASE PROVIDE OUTSIDE AIR
 CALUCALTIONS PER 2001 FBC(M) TABLE
 403.3.
  
 2.PROVIDE OUTSIDE AIR DUCT SIZE,
 MATERIAL AND INTAKE.
  
 3.SEE COMMENT #3 BY DEWEY PALMER,
 ELECTRICAL PLAN REVIEW.PROVIDE
 REQUIRED LICENSE NUMBERS AND
 SIGNATURES.
 PLANS ARE OTHERWISE CODE COMPLIANT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-01-06 Cont ID  
Sent By jleech Date 2005-01-06 Time 14:06 Rev Time 0.50
Received By jleech Date 2005-01-06 Time 14:06 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-12-07 Cont ID  
Sent By kstevens Date 2004-12-07 Time 15:48 Rev Time 0.75
Received By kstevens Date 2004-12-07 Time 15:47 Sent To  
Notes
2004-12-07 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 FROM PREVIOUS REVIEW:
 1) SHT A-1 WATER RISER DIAGRAM SHOWS TWO
 1/2" LINES TO A FIXTURE NOT SHOWN ON THE
 FLOOR PLAN, AND NOW SAYS WATER HAMMER
 ARRESTORS. PLEASE INDICATE WHAT THE
 LINES SUPPLY. SECTION 104.2.1
 2) SHT A-1 WATER HEATER SHALL BE
 ACCESSIBLE. OPENING IN THE CABINET DOES
 NOT APPEAR TO BE LARGE ENOUGH TO REMOVE
 THE WATER HEATER. SUPPLY MEASUREMENTS
 FOR THE WATER HEATER AND THE DOOR
 OPENING. SECTIONS 104.2.1 & 501.4
 3) KITCHEN SINK SHALL BE ACCESSIBLE.
 SUBMIT A DETAIL SHOWING KNEE CLEARANCE
 11-4.24.3, SINK DEPTH 11-4.24.4, CLEAR
 FLOOR SPACE (FORWARD APPROACH) FIG 32,
 AND SECTION 11-4.24.5, AND EXPOSED PIPES
 AND SURFACES 11-4.24.6.
 4) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESSM AND LICENSE NUMBER
 ON EACH SHEET. FAC 61G15-23.--2(2) AND
 FS 471..025
 *******NEW COMMENT*******
 1B) SEE ATTACHED SHEET CONCERNING THE
 DESIGN PROFESSIONAL AND FS
 553.80(2)(B).
  
  
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-06 Cont ID  
Sent By kstevens Date 2004-11-06 Time 08:05 Rev Time 0.75
Received By kstevens Date 2004-11-06 Time 08:05 Sent To  
Notes
2004-11-06 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT A-1 WATER RISER DIAGRAM SHOW TWO
 1/2 INCH LINES TO A FIXTURE NOT SHOWN ON
 THE FLOOR PLAN, AND HAS "WATER HAMPERS"
 INDICATED ON THEM. PLEASE CLARIFY.
 SECTION 104.2.1
 2) SHT A-1 WATER HEATER SHALL BE
 ACCESSIBLE. PLEASE SUMBIT A DETAIL
 SHOWING HOW THE HEATER WILL BE SERVICED
 AND REMOVED IF NEEDED. SECTION 501.4
 3) KITCHEN SINK SHALL BE ACCESSIBLE.
 SUBMIT A DETAIL SHOWING HEIGHT
 11-4.24.2
 KNEE CLEARANCE 11-4.24.3, SINK DEPTH
 11-4.24.4, CLEAR FLOOR SPACE (SHALL BE
 PROVIDED IN FRONT OF A SINK TO ALLOW
 FORWARD APPROACH. - SHALL EXTEND MAXIMUM
 OF 19 IN. UNDER THE SINK - FIG 32)
 SECTION 11-4.24.5, AND EXPOSED PIPES AND
 SURFACES 11-4.24.6
 4) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS, AND LICENSE NUMBER
 ON EACH SHEET. FAC 61G15-23.002(2) AND
 FS 471.025
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]