Plan Review Stops For Permit 04100617 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-01-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-01-06 |
Time |
16:02 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2005-01-06 |
Time |
16:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-12-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-12-07 |
Time |
10:50 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2004-12-02 |
Time |
10:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-10-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-10-29 |
Time |
07:15 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2004-10-29 |
Time |
07:10 |
Sent To |
|
|
Notes |
2004-10-29 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04100617 | | ADD: 1822 UPLAND RD | | CONT: BAINES | | TEL: (561)718-3997 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1STREVIEW | | ACTION: DENIED | | | | 1) PLANS, SPECIFICATIONS,REPORTS OR | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | RECORD SHALL HAVE THE SIGNATURE AND | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | TO THE DOCUMENT. | | FL STATE STAT: 61G15-23.002 ENGINEERS | | FL ATATE STAT: 61G16.003 ARCHITECTS | | SEE BBC DESIGNS IN THE TITLEBLOCK, IN- | | CLUDE REQUIRED LICENSE NUMBERS FOR ARCH | | AND INTERIOR DESIGNERS. FAC 16.004, | | 61G15-23 FOR ENGINEERS. | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 3) KITCHEN ENTRY PULL SIDE OF DOOR: | | 11-4.13.6 MANEUVERING CLEARENCES | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | AT DOORS THAT ARE NOT AUTOMATIC OR | | POWER-ASSISTED SHALL BE AS SHOWN IN | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | IN THE REQUIRED CLEARENCES SHALL BE | | CLEAR & LEVEL. PULL SIDE OF DOOR 18" | | MINIMUM. | | | | 4)1012.1.4. DURING ITS SWING, ANY | | DOOR IN A MEANS OF EGRESS SHALL LEAVE | | UNOBSTRUCTED AT LEAST 1/2 OF THE REQUIRE | | REQUIRED WIDTH OF AN AISLE, CORRIDOR, | | PASSAGEWAY, OR LANDING, NOR PROJECT MORE | | THAN 7" INTO THE REQUIRED WIDTH.FOR LESS | | THAN 50 OCCUPANTS A MINIMUM OF 36" CORRI | | DOR IS REQUIRED, MINIMUM CLEAR AISLE | | WIDTH OF 18" WITH DOOR OPEN 90 DEGREES | | TO THE DOOR JAMB, SEE H/C RESTROOM. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-12-27 |
Time |
08:37 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-12-27 |
Time |
11:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-11-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-11-18 |
Time |
19:37 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-11-18 |
Time |
19:32 |
Sent To |
|
|
Notes |
2004-11-18 00:00:00 | *********** UNSAT *********** | | | | ***PLEASE SEE PACKAGE DID NOT COME BACK | | WITH ORIGINAL PERMIT APPLICATION ?? *** | | | | 1)NOTE: PLEASE CORRELATE A/C HEAT LOAD | | WITH MECH PLANS. | | ONE SHOWS 10KW AND THE OTHER 8KW? | | | | 2)NOTE: PLEASE SEE 700.12E FOR | | CIRCUITING OF EM LTS. SHOWN ON W/ OFFICE | | LTS. | | | | 3)NOTE: PLEASE SEE MISSING RECEPT FOR | | ROOFTOP A/C 210.63 GFI | | | | 4)NOTE: PLEASE SEE PLANS ARE NOT | | PERMITTED TO HAVE ANY HANDWRITTEN | | CHANGES OR ADDITIONS TO PLANS WHICH ARE | | SIGNED, DATED AND SEALED BY AN | | ENGINEER. | | FS 471.025 | | | | ** PLEASE SEE TITLE BLOCK MENTIONS TED | | BERGUS CONTRACTOR, YET PERMIT | | APPLICATION IS FOR BAINES BLDG?? | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | REVIEWER(S) WHICH MAY AFFECT ELECTRICAL | | PLANS. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-10-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-23 |
Time |
07:35 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-10-23 |
Time |
07:35 |
Sent To |
|
|
Notes |
2004-10-23 00:00:00 | ****** UNSAT ******* | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS. THERE ARE A COUPLE OF ITEMS NOT | | IDENTIFIED. | | PLEASE ALSO SEE 700.12E FOR CIRCUITING | | OF EM/EXT LTS. SOME SHOWN ON WITH | | GARAGE OUTLETS? | | PLEASE SEE POSSIBLE FIRE REVIEW COMMENTS | | FOR PLACEMENT OF EXIT SIGNS.NOTE ONLY: | | | | 2)NOTE: PLEASE SEE CIRCUITING FOR RECEPT | | 'S. PLEASE SEE 220.13 FOR 180VA PER | | DEVICE. PLEASE SEE # OF RECEPTS ON | | CIRCUITS WHICH SEEM TO OVERLOAD CIRCUIT- | | -S.MAX 1920 FOR A 20A CIR. | | | | 3)NOTE: PLEASE SEE BBC DESIGNS IN TITLE | | BLOCK. PLEASE INCLUDE REQUIRED LICENSE | | #'S ? PER FS 481. ARCH/INT DESIGN. | | PLEASE ALSO SEE FAC 61G1-16.004, | | 61G15-23.002 FOR ENGINEER. | | PLEASE SEE MISSING PRINTED NAME AND #. | | FBC 104.2.1 | | | | PLEASE SEE POSSIBLE NOTES FROM OTHER | | REVIEWER(S) WHICH MAY AFFECT ELECTRICAL | | PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2004-12-15 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-11-05 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-12-15 |
Time |
09:55 |
Sent To |
|
|
Notes |
2004-11-05 00:00:00 | 1) VEHICLES STORED IN BUILDING | | SHALL HAVE THE BATTERIES DISCONNECTED. | | | | 2) DOOR SWINGS TO FAR INTO CORRIDOR. | | PLEASE REVISE PLANS. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-20 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-20 |
Time |
11:13 |
Sent To |
|
|
Notes |
2004-12-20 00:00:00 | SENT TO "COMM BD#49 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-11-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-11-15 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-11-15 |
Time |
08:45 |
Sent To |
|
|
Notes |
2004-11-15 00:00:00 | TO COMM BD# |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-11-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-11-06 |
Time |
08:21 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2004-10-18 |
Time |
15:22 |
Sent To |
|
|
Notes |
2004-10-18 00:00:00 | TO COMM BD#28 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-12-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-12-31 |
Time |
10:12 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-12-31 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-12-04 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-12-04 |
Time |
09:25 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2004-12-04 |
Time |
08:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-11-04 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-11-04 |
Time |
14:56 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-11-04 |
Time |
14:09 |
Sent To |
|
|
Notes |
2004-11-04 00:00:00 | DENIED: | | 1.PLEASE PROVIDE OUTSIDE AIR | | CALUCALTIONS PER 2001 FBC(M) TABLE | | 403.3. | | | | 2.PROVIDE OUTSIDE AIR DUCT SIZE, | | MATERIAL AND INTAKE. | | | | 3.SEE COMMENT #3 BY DEWEY PALMER, | | ELECTRICAL PLAN REVIEW.PROVIDE | | REQUIRED LICENSE NUMBERS AND | | SIGNATURES. | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2005-01-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-01-06 |
Time |
14:06 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-01-06 |
Time |
14:06 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-12-07 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-12-07 |
Time |
15:48 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2004-12-07 |
Time |
15:47 |
Sent To |
|
|
Notes |
2004-12-07 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | FROM PREVIOUS REVIEW: | | 1) SHT A-1 WATER RISER DIAGRAM SHOWS TWO | | 1/2" LINES TO A FIXTURE NOT SHOWN ON THE | | FLOOR PLAN, AND NOW SAYS WATER HAMMER | | ARRESTORS. PLEASE INDICATE WHAT THE | | LINES SUPPLY. SECTION 104.2.1 | | 2) SHT A-1 WATER HEATER SHALL BE | | ACCESSIBLE. OPENING IN THE CABINET DOES | | NOT APPEAR TO BE LARGE ENOUGH TO REMOVE | | THE WATER HEATER. SUPPLY MEASUREMENTS | | FOR THE WATER HEATER AND THE DOOR | | OPENING. SECTIONS 104.2.1 & 501.4 | | 3) KITCHEN SINK SHALL BE ACCESSIBLE. | | SUBMIT A DETAIL SHOWING KNEE CLEARANCE | | 11-4.24.3, SINK DEPTH 11-4.24.4, CLEAR | | FLOOR SPACE (FORWARD APPROACH) FIG 32, | | AND SECTION 11-4.24.5, AND EXPOSED PIPES | | AND SURFACES 11-4.24.6. | | 4) ENGINEERS SHALL LEGIBLY INDICATE | | THEIR NAME, ADDRESSM AND LICENSE NUMBER | | ON EACH SHEET. FAC 61G15-23.--2(2) AND | | FS 471..025 | | *******NEW COMMENT******* | | 1B) SEE ATTACHED SHEET CONCERNING THE | | DESIGN PROFESSIONAL AND FS | | 553.80(2)(B). | | | | | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-11-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-11-06 |
Time |
08:05 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2004-11-06 |
Time |
08:05 |
Sent To |
|
|
Notes |
2004-11-06 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) SHT A-1 WATER RISER DIAGRAM SHOW TWO | | 1/2 INCH LINES TO A FIXTURE NOT SHOWN ON | | THE FLOOR PLAN, AND HAS "WATER HAMPERS" | | INDICATED ON THEM. PLEASE CLARIFY. | | SECTION 104.2.1 | | 2) SHT A-1 WATER HEATER SHALL BE | | ACCESSIBLE. PLEASE SUMBIT A DETAIL | | SHOWING HOW THE HEATER WILL BE SERVICED | | AND REMOVED IF NEEDED. SECTION 501.4 | | 3) KITCHEN SINK SHALL BE ACCESSIBLE. | | SUBMIT A DETAIL SHOWING HEIGHT | | 11-4.24.2 | | KNEE CLEARANCE 11-4.24.3, SINK DEPTH | | 11-4.24.4, CLEAR FLOOR SPACE (SHALL BE | | PROVIDED IN FRONT OF A SINK TO ALLOW | | FORWARD APPROACH. - SHALL EXTEND MAXIMUM | | OF 19 IN. UNDER THE SINK - FIG 32) | | SECTION 11-4.24.5, AND EXPOSED PIPES AND | | SURFACES 11-4.24.6 | | 4) ENGINEERS SHALL LEGIBLY INDICATE | | THEIR NAME, ADDRESS, AND LICENSE NUMBER | | ON EACH SHEET. FAC 61G15-23.002(2) AND | | FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|