Plan Review Details - Permit 04100530
Plan Review Stops For Permit 04100530
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2006-03-14 Cont ID  
Sent By mperson Date 2006-03-14 Time 10:24 Rev Time 0.33
Received By mperson Date 2006-03-14 Time 10:23 Sent To PC
Notes
2006-03-14 00:00:00NOTE: DUPLICATE PERMIT AND STAMPED PLANS

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2004-11-27 Cont ID  
Sent By kstevens Date 2004-11-27 Time 09:06 Rev Time 0.33
Received By kstevens Date 2004-11-27 Time 09:05 Sent To  
Notes
2004-11-27 00:00:00 
  
  
 PER N. MELICK MANUFACTURE INFO
 NOT REQUIRED FOR 1 & 2 FAMILY HOMES.
 JULY 17, 2002 OFFICAL INTERPRETATION.
 THE FIELD INSPECTOR SHALL VERIFY THE
 INSTALLED EQUIPMENT INPUT DOES NOT EX-
 CEED THE PIPE SIZING.
  
 IF DRYER ROOM IS A CONFINED SPACE,
 OPENINGS REQUIRED PER SECTION 304.3.1 0R
 SECTION 304.3.2 SHALL BE INSTALLED.
 MINIMUM 1,000 CUBIC FEET REQUIRED.
  
  
  
  
  
  
 .

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-09 Cont ID  
Sent By adarroug Date 2006-03-09 Time 17:46 Rev Time 0.00
Received By adarroug Date 2006-03-09 Time 17:46 Sent To G
Notes
2006-03-09 00:00:00TO "G" BOX/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 14:55 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 14:55 Sent To P
Notes
2004-11-12 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-14 Cont ID  
Sent By csiegber Date 2004-10-14 Time 14:42 Rev Time 0.00
Received By csiegber Date 2004-10-14 Time 14:42 Sent To P
Notes
2004-10-14 00:00:00TO GAS

Review Stop P PLUMBING
Rev No 2 Status N Date 2004-11-27 Cont ID  
Sent By kstevens Date 2004-11-27 Time 09:04 Rev Time 0.00
Received By kstevens Date 2004-11-27 Time 09:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-10-28 Cont ID  
Sent By csiegber Date 2004-10-14 Time 14:42 Rev Time 0.50
Received By kstevens Date 2004-10-28 Time 19:13 Sent To  
Notes
2004-10-28 00:00:00DENIED
 REFERENCE: FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
  
 1. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2001 FUEL
 GAS CODE SECTION 304. - SEE DRYER AND
 WATER HEATER ROOMS.
 2) SHTUOFF VALVES ARE REQUIRED UPSTREAM
 OF THE GAS REGULATORS. SECTION 409.7
 SHOW ON GAS RISER DIAGRAM.
 3) ALL DRAWINGS SHALL BEAR THE NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR
 THE DESIGN. SECTION 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]