Plan Review Stops For Permit 04100413 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-02-25 |
Time |
07:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-02-25 |
Time |
07:26 |
Sent To |
|
|
Notes |
2005-02-25 00:00:00 | PROVISO | | | | 1) A SEPARATE PERMIT WILL BE REQUIRED | | FOR THE STORM PANELS. SUBMIT 2 COPIES OF | | STATE PRODUCT APPROVALS (INCLUDING | | INSTALLATION INSTRUCTIONS), KEY PLANS | | AND INSTALLATION SCHEDULE WITH FASTENERS | | AND SPACING LISTED. | | | | 2) A SEPARATE PERMIT WILL ALSO BE | | REQUIRED FOR MECHANICAL AND REROOF. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-01-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-01-31 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-01-31 |
Time |
10:06 |
Sent To |
|
|
Notes |
2005-01-31 00:00:00 | DENIED | | | | | | 1)PRODUCT APPROVALS SUBMITTED | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | 2003 ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | INFORMATION PLEASE SEE THE STATE WEBSITE | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | BE SUBMITTED WITH A COVER SHEET THAT | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. I HAVE | | ATTACHED THE COVER SHEET WITH THE FL# | | FOR THE TRACO WINDOWS, HOWEVER I DID NOT | | SEE ONE FOR THE POMA STORM PANELS. | | SUBMIT FLORIDA PRODUCT APPROVAL FOR | | STORM PANELS. | | | | 2) SUBMIT TWO COPIES OF A KEY PLAN AND | | INSDTALLATION SCHEDULE FOR THE STORM | | PANELS. SPECIFY THE TYPE OF MOUNT, THE | | TYPE OF FASTENERS AND THE FASTENER | | SPACING. | | | | 3) A SEPARATE PERMIT WILL BE REQUIRED | | FOR THE MECHANICAL SYSTEMS. SUBMIT | | MECHANICAL PLANS, ENERGY CALCS. AND | | MANUAL J CALCS. WITH APPLICATION. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
N |
Date |
2004-12-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2004-12-22 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2004-12-22 |
Time |
14:08 |
Sent To |
|
|
Notes |
2004-12-22 00:00:00 | REVISION DENIED | | | | 1) INDICATE THE VALUE OF THE WORK | | INCLUDED IN THE REVISION SO THAT THE | | PERMIT VALUE CAN BE INCREASED TO INCLUDE | | THE ADDITIONAL SCOPE OF WORK. | | | | 2)PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. | | WWW.FLORIDABUILDING.ORG | | | | 3) SUBMIT 2 COPIES OF STATE/LOCAL | | PRODUCT APPROVALS FOR THE NEW WINDOWS. | | | | 4) SUBMIT PRODUCT APPROVALS, KEY PLAN | | AND INSTALLATION SCHEDULE FOR STORM | | PANELS OR PRODUCT APPROVALS FOR IMPACT | | RESISTANT WINDOWS. | | | | 5) SUBMIT ELECTRICAL PLANS WITH RISER | | DIAGRAM AND CALCULATIONS, OR REMOVE | | ELECTRIC NOTE FROM SCOPE OF WORK ON A1 | | AND APPLY UNDER A SEPARATE PERMIT. | | | | 6) THE EXTENT OF STRUCTURAL REPAIRS IS | | TO BE EVALUATED BY THE FIELD INSPECTOR | | AND SIGNED AND SEALED DRAWINGS OF | | REPAIRS FROM AN ENGINEER OR ARCHITECT | | SUBMITTED IF NECESSARY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-10-20 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2004-10-20 |
Time |
08:28 |
Rev Time |
0.25 |
Received By |
spalmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2004-10-20 00:00:00 | APPROVED PER STEVE NICOLOSI |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2005-02-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-02-18 |
Time |
12:57 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-02-18 |
Time |
12:31 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-01-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-01-26 |
Time |
15:27 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-01-26 |
Time |
07:36 |
Sent To |
B |
|
Notes |
2005-01-25 00:00:00 | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1) LAUNDRY CIRCUIT LOAD. A LOAD OF NOT | | LESS THAN 1500 VOLT-AMPERES SHALL BE | | INCLUDED FOR EACH 2-WIRE LAUNDRY BRANCH | | CIRCUIT INSTALLED AS REQUIRED BY | | 210.11(C)(2). THIS LOAD SHALL BE | | PERMITTED TO BE INCLUDED WITH THE | | GENERAL LIGHTING LOAD AND SUBJECTED TO | | THE DEMAND FACTORS PROVIDED IN TABLE | | 220.11. | | | | 2} 220.18 ELECTRIC CLOTHES DRYERS | | DWELLING UNIT(S). | | THE LOAD FOR HOUSEHOLD ELECTRIC CLOTHES | | DRYERS IN A DWELLING UNIT(S) SHALL BE | | 5000 WATTS (VOLT-AMPERES) OR THE | | NAMEPLATE RATING, WHICHEVER IS LARGER, | | FOR EACH DRYER SERVED. | | | | 3} 110.9 INTERRUPTING RATING. | | EQUIPMENT INTENDED TO INTERRUPT CURRENT | | AT FAULT LEVELS SHALL HAVE AN | | INTERRUPTING RATING SUFFICIENT FOR THE | | NOMINAL CIRCUIT VOLTAGE AND THE CURRENT | | THAT IS AVAILABLE AT THE LINE TERMINALS | | OF THE EQUIPMENT. | | | | 4} THE LOCATION OF THE ELECTRICAL | | SERVICE EQUIPMENT IS IN VIOLATION OF | | ARTICLE 110.26 WITH RELATIONSHIP TO THE | | STEPS. | | | | 6} SEE ARTICLE 210.52(E) FOR OUTSIDE | | RECEPTACLE REQUIREMENTS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-02-11 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-02-11 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-02-11 |
Time |
15:39 |
Sent To |
E |
|
Notes |
2005-02-11 00:00:00 | TO "BT" DESK/RESUB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-01-19 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-19 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-19 |
Time |
10:21 |
Sent To |
E |
|
Notes |
2005-01-19 00:00:00 | TO "E" BOX./RESUB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-12-13 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-13 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-13 |
Time |
15:52 |
Sent To |
B |
|
Notes |
2004-12-13 00:00:00 | SENT TO "B" TO RES BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-12-09 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-09 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-09 |
Time |
10:27 |
Sent To |
Z |
|
Notes |
2004-12-09 00:00:00 | SENT TO "Z" BOX. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2004-12-22 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-12-22 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-12-22 |
Time |
13:18 |
Sent To |
B |
|
Notes |
2004-12-22 00:00:00 | GREEN CARD SHOWS APTS.OK FOR | | RENOVATION |
|
|