Plan Review Details - Permit 04100192
Plan Review Stops For Permit 04100192
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-01-19 Cont ID  
Sent By lsmith Date 2005-01-19 Time 08:20 Rev Time 0.50
Received By lsmith Date 2005-01-19 Time 08:20 Sent To  
Notes
2005-01-19 00:00:00DELETED GAS HEATER FROM PERMIT, DEDUCTED
 2175 FROM VALUE FOR HEATER LS

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-11-23 Cont ID  
Sent By lsmith Date 2004-11-23 Time 15:53 Rev Time 0.75
Received By lsmith Date 2004-11-23 Time 15:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-08-12 Cont ID  
Sent By btrobaug Date 2005-08-12 Time 08:10 Rev Time 0.33
Received By btrobaug Date 2005-08-12 Time 08:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-07-21 Cont ID  
Sent By btrobaug Date 2005-07-21 Time 16:04 Rev Time 0.33
Received By btrobaug Date 2005-07-21 Time 15:57 Sent To PC
Notes
2005-07-21 00:00:00 
 ALL PLANS DRAWN BY AN
 ARCHITECT/ENGINEER CONTAIN-
 -ING A TITLE BLOCK: MUST BE SIGNED,
 DATED AND SEALD BY THAT ARCH/ENG.
 PER FS 481.221 471.025
 FAC 61G15-23.002, 61G1-16.004
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-05-24 Cont ID  
Sent By btrobaug Date 2005-05-24 Time 06:45 Rev Time 0.33
Received By btrobaug Date 2005-05-23 Time 17:36 Sent To P
Notes
2005-05-24 00:00:00 
 PLEASE SUBMIT ELECTRICAL SCHEMATIC FOR
 REVIEW. REVISION SUBMITTED FOR PLUMBING
 ONLY.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-11-12 Cont ID  
Sent By dpalmer Date 2004-11-12 Time 17:49 Rev Time 0.25
Received By dpalmer Date 2004-11-12 Time 17:49 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-08-10 Cont ID  
Sent By adarroug Date 2005-08-10 Time 17:33 Rev Time 0.00
Received By adarroug Date 2005-08-10 Time 17:33 Sent To E
Notes
2005-08-10 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-06-29 Cont ID  
Sent By adarroug Date 2005-06-29 Time 10:13 Rev Time 0.00
Received By adarroug Date 2005-06-29 Time 10:13 Sent To E
Notes
2005-06-29 00:00:00TO "BTROBAUG" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-05-23 Cont ID  
Sent By adarroug Date 2005-05-23 Time 16:42 Rev Time 0.00
Received By adarroug Date 2005-05-23 Time 16:42 Sent To E
Notes
2005-05-23 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-01-07 Cont ID  
Sent By mjacobs Date 2005-01-07 Time 08:37 Rev Time 0.00
Received By mjacobs Date 2005-01-07 Time 08:37 Sent To P
Notes
2005-01-07 00:00:00TO "P" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 16:40 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 16:40 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-02 Cont ID  
Sent By csiegber Date 2004-11-02 Time 12:40 Rev Time 0.00
Received By csiegber Date 2004-11-02 Time 12:40 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-06 Cont ID  
Sent By csiegber Date 2004-10-06 Time 14:27 Rev Time 0.00
Received By csiegber Date 2004-10-06 Time 14:27 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2005-06-10 Cont ID  
Sent By pschmitz Date 2005-06-10 Time 13:24 Rev Time 0.00
Received By pschmitz Date 2005-06-10 Time 13:24 Sent To PC
Notes
2005-06-10 00:00:00PLUMBING PLAN REVIEW FBC2001DENIED
 15) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 QUESTIONS CONTACT,PAUL SCHMITZ
 561-805-6692

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-01-18 Cont ID  
Sent By kstevens Date 2005-01-18 Time 17:19 Rev Time 0.50
Received By kstevens Date 2005-01-18 Time 17:19 Sent To B1
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-23 Cont ID  
Sent By kstevens Date 2004-11-23 Time 13:21 Rev Time 0.50
Received By kstevens Date 2004-11-23 Time 13:21 Sent To  
Notes
2004-11-23 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING
 POOLS
  
  
 A) THE FOLLOWING INFORMATION IS REQUIRED
 FOR THE POOL PERMIT. ADD TO NOTES,
 SUBMIT A DETAIL, OR SUBMIT MANUFACTURE
 SPECIFICATION SHEETS AS REQUIRED.
 1) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 2)FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUF. CUT SHEETS SUBMITTAL).
 3) FBC-2001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
  
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-11-12 Cont ID  
Sent By mmclean Date 2004-11-12 Time 11:03 Rev Time 0.00
Received By mmclean Date 2004-11-12 Time 11:03 Sent To I
Notes
2004-11-12 00:00:00NOTE: MUST BE 5FT ON THE SIDE AND REAR

Review Stop Z ZONING
Rev No 1 Status F Date 2004-10-19 Cont ID  
Sent By csiegber Date 2004-10-06 Time 14:27 Rev Time 0.00
Received By mmclean Date 2004-10-19 Time 18:01 Sent To  
Notes
2004-10-19 00:00:00DENIED, MUST BE 5FT ON THE SIDE & REAR.
 NEED TO PROVIDE TWO COPY OF SURVEY
 SHOWING SETBACK.CALLED & LEFT MSG ON
 VOICE MAIL, FILE B FOR P/U MM