Plan Review Stops For Permit 04090873 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-01-25 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2005-01-25 |
Time |
16:10 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2005-01-25 |
Time |
16:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-02-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-02-22 |
Time |
09:09 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-02-22 |
Time |
09:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-02-03 |
Time |
14:56 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-02-02 |
Time |
16:45 |
Sent To |
|
|
Notes |
2005-02-03 00:00:00 | | | THE LOAD CALCULATIONS SUBMITTED MUST BE | | CORRECTED AS FOLLOWS. | | | | 1} THE PLANS MUST CONTAIN THE PRINTED AN | | SIGNED NAME OF THE DESIGNER OF RECORD | | PER 104.2.1 FBC. | | | | 2} THE GENERAL LIGHTING LOAD IS LISTED @ | | 6600 AND THEN A CALULATION OF 3 WATTS | | PER SQUARE FOOT IS SHOWN, WHICH WOULD BE | | THE GENERAL LIGHTING LOAD, @ 3000. | | PLEASE CORRELATE. | | | | 3} THE SMALL APPLIANCE LOAD MUST COMPLY | | WITH 220.16, 2@ 1500=3000WATTS MINIMUM. | | | | 4} THE WASHER IS INCORRECTLY CALCULATED | | AT 10000 WATTS, BUT MUST BE A MINIMUM OF | | 1500 WATTS IF REFERRING TO THE LAUNDRY | | LOAD REQUIREMENT. | | | | 5} A/C #1&2 ARE SHOWN AS 5000 EACH, AND | | SHOWN AGAIN AT 15000 AND 10000. PLEASE | | CORRELATE. | | | | 6} THE RANGE MUST BE CALCULATED PER | | 220.19. | | | | 7} CLARIFY "HWIT" ON CALC. | | | | 8} THE POOL PUMP AND HEATER MUST BE | | CALCULATED AT 125%. SEE ARTICLES 424 & | | 430. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-01-19 |
Time |
13:44 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-01-19 |
Time |
13:28 |
Sent To |
P |
|
Notes |
2005-01-19 00:00:00 | | | | | PLEASE PROVIDE A CALCULATION | | INCLUDING ALL ADDED LOADS IMPOSED,ALL | | EXISTING LOADS AND THE EXISTING OR | | PROPOSED SERVICE SPECIFICATIONS PER | | 215.15. | | | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-02-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-16 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-16 |
Time |
11:38 |
Sent To |
B |
|
Notes |
2005-02-16 00:00:00 | TO BTROBAUG DESK/RESUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-02-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-02 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-02 |
Time |
16:22 |
Sent To |
E |
|
Notes |
2005-02-02 00:00:00 | TO "BT" DESK/RESUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-01-19 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-19 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-19 |
Time |
08:44 |
Sent To |
E |
|
Notes |
2005-01-19 00:00:00 | TO "E" BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-01-12 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-12 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-12 |
Time |
11:24 |
Sent To |
Z |
|
Notes |
2005-01-12 00:00:00 | TO "Z" BOX/RESUB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-10-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-04 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-04 |
Time |
09:36 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-01-22 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-01-22 |
Time |
10:09 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-01-22 |
Time |
10:09 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-01-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-01-18 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-01-18 |
Time |
14:44 |
Sent To |
I |
|
Notes |
2005-01-18 00:00:00 | APPROVED ZBA CASE #3137 EDNASHA BOWERS, | | PLANNER 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2004-10-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-04 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-10-15 |
Time |
15:05 |
Sent To |
|
|
Notes |
2004-10-15 00:00:00 | DENIED, NEED TO PROVIDE TWO COPY OF | | VARIANCE APPROVAL (IF APPLIED) OR POOL | | MUST BE BUILT BEYOND THE 25FT FRONT | | SETBACK MEETING ALL SETBACK GUIDELINES. | | CALLED LEFT MSG FOR SHAUN ON VOICE MAIL | | FILE P FOR P/U MM |
|
|