Plan Review Stops For Permit 04080987 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-01-19 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-01-19 |
Time |
15:44 |
Sent To |
|
|
Notes |
2005-01-19 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | REVISED PLANS ORIGINALLY SUBMITTED | | 12/7/04 AND RE-SUBMITTED 1/18/05. | | | | --PROVISO-- | | SHEETS LS-1 AND A1-2 REDLINED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2004-12-20 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2005-06-02 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-20 |
Time |
11:39 |
Sent To |
|
|
Notes |
2004-12-20 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | REVISED PLANS SUBMITTED 12/7/04. | | | | 1) FBC 1006.2.4PROTECTION OF EXTERIOR | | EXIT STAIR.SEE SHEET LS-1 FOR REDLINED | | COMMENT.AMEND THE PLAN TO INCORPORATE | | THE NOTE BEFORE RESUBMITTAL. | | | | 2) FBC* 11-4.3.2(1)ACCESSIBLE ROUTE | | TO BUILDING ENTRANCE.SHEET A1-1, THE | | ACCESSIBLE CAR PARKING AND | | ACCESSIBILITY | | RAMPS HAVE BEEN REVISED, AMEND THE | | PLANS | | TO SHOW THE ACCESSIBLE ROUTE FROM | | PARKING TO THE ENTRY LOBBY (MAIN | | ENTRANCE). | | | | 3) FBC* F102.2.8SHEETS A1-2, A2-1, | | A4-3 AND A4-4 ALL REFER TO A FABRIC | | AWNING OVER THE ENTRANCE.PERMANENT | | CANOPIES/ AWNINGS AND THEIR SUPPORTS, | | ON BUILDINGS LOCATED IN THE FIRE | | DISTRICT, SHALL BE OF NON-COMBUSTIBLE | | MATERIAL, FIRE RETARDANT TREATED WOOD, | | WOOD OF TYPE III SIZES OR OF 1-HOUR | | RESISTANT CONSTRUCTION.ANNOTATE THE | | PLANS TO DEMONSTRATE COMPLIANCE. | | | | 4) FBC 1608.2.2THE GUARDRAIL STRENGTH | | NOTE HAS BEEN REMOVED FROM SHEETS A4-3 | | AND A4-4.THERE ARE STILL TWO | | GUARDRAILS SHOWN ON SECTION 01/A5-1 AND | | WEST ELEVATION 01/A4-4 (ALSO SHOWN ON | | SECOND FLOOR PLAN - SHEET A1-2).THE | | GUARDRAILS SHALL BE DESIGNED AND | | CONSTRUCTED FOR A CONCENTRATED LOAD OF | | 200 LB APPLIED IN ANY DIRECTION AT THE | | TOP OF THE GUARDRAIL, A CONCENTRATED | | HORIZONTAL LOAD OF 200 LB APPLIED ON A | | 1 | | SQ FT AREA AT ANY POINT, AND A LINE | | LOAD OF 50 PLF APPLIED HORIZONTALLY AT | | THE REQUIRED GUARDRAIL HEIGHT WITH A | | SIMULTANEOUS LINE LOAD OF 100 PLF | | APPLIED VERTICALLY DOWNWARD ON THE TOP | | OF THE GUARDRAIL. THESE LOADS SHALL NOT | | BE APPLIED SIMULTANEOUSLY (UNLESS NOTED | | ABOVE) BUT SHALL BE APPLIED | | INDIVIDUALLY | | TO PRODUCE MAXIMUM STRESS IN EACH OF | | THE COMPONENTS OR SUPPORTS. | | AMEND/ANNOTATE THE PLANS TO SPECIFY | | THESE DESIGN LOADS. | | ALSO, THE ELEVATOR 'BRIDGE' GUARDRAIL | | HEIGHT REQUIREMENT OF 42" SHALL BE | | ANNOTATED ON THE PLANS. | | | | 5) TO EXPEDITE REVIEW OF A RESUBMITTAL | | WHICH REQUIRES NEW PLANS IN ORDER TO | | ADDRESS THE ABOVE COMMENTS, THE OLD | | SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | REMAINING OLD SHEETS, TO FORM A SET OF | | 'OLD/VOID SHEETS', FOR COMPARISON OF | | REVISIONS WHEN REVIEWING THE | | RESUBMITTED | | PLANS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2004-12-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-08 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-08 |
Time |
14:33 |
Sent To |
|
|
Notes |
2004-12-08 00:00:00 | STRUCTURAL SUBMITTAL ON 12/7/04 FOR | | SKETCH CLARIFICATION ON PARAPET WALL | | DETAIL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2004-12-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-08 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-08 |
Time |
14:33 |
Sent To |
|
|
Notes |
2004-12-08 00:00:00 | STRUCTURAL SUBMITTAL ON 12/7/04 FOR | | SKETCH CLARIFICATION ON MACHINE ROOM TIE | | BEAM. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-12-08 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-12-08 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-12-08 |
Time |
14:33 |
Sent To |
|
|
Notes |
2004-12-08 00:00:00 | STRUCTURAL SUBMITTAL ON 12/7/04 FOR | | SKETCH CLARIFICATION ON MACHINE ROOM | | FOOTING. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-10-05 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-10-05 |
Time |
17:33 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-10-05 |
Time |
17:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-09-15 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-09-15 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-09-15 |
Time |
17:56 |
Sent To |
|
|
Notes |
2004-09-15 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | 1) FBC 1006.2.4SHEET LS-1,PROTECTION | | OF EXTERIOR EXIT STAIRS.THE ONE-HOUR | | FIRE RATED WALL SHOWN ON THE FIRST AND | | SECOND FLOOR LIFE SAFETY PLANS SHALL BE | | EXTENDED TO COVER AN AREA THAT EXTENDS | | 10 FEET BEYOND THE EDGE OF THE LANDING. | | ALTERNATIVEY, THE PAINTED METAL WALL | | PANEL ASSEMBLY (SHEET A1-2, KEY NOTE 10) | | SHALL BE FIRE-RATED.AMEND THE PLANS TO | | DEMONSTRATE COMPLIANCE. | | | | 2) FBC 1015.4SHEET A4-4.THE 'TYPICAL | | NOTE' COVERING STRENGTH OF GUARDRAILS | | SHALL ALSO APPLY TO THE METAL WALL PANEL | | (KEY NOTE ITEM 9).AMEND THE PLANS TO | | DEMONSTRATE COMPLIANCE. | | | | 3) FBC 2405.2THE GLAZED PANELS | | ADJACENT DOORS 101 AND 110 ARE IN A | | 'HAZARDOUS LOCATION' AND ARE REQUIRED TO | | BE SAFETY GLASS SATISFYING THE | | REQUIREMENTS OF THE CONSUMER PRODUCT | | SAFETY COMMISSION 16, CODE OF FEDERAL | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | PART 1201).SUBMIT DETAILS TO | | DEMONSTRATE COMPLIANCE. | | | | 4) FBC* F102.2.7SHEET A4-3, FOAM | | MOULDING (KEY NOTE 21).ARCHITECTURAL | | TRIM ON BUILDINGS LOCATED IN THE FIRE | | DISTRICT, SHALL BE CONSTRUCTED OF | | APPROVED NON-COMBUSTIBLE MATERIALS OR | | FIRE RETARDANT TREATED WOOD.ANNOTATE | | THE PLANS TO DEMONSTRATE COMPLIANCE. | | | | 5) SUBMIT A PRODUCT APPROVAL FOR THE | | MODIFIED BITUMEN ROOFING SYSTEM | | REFERENCED ON SHEET A2-1, ROOF PLAN. | | ALSO, (FBC* F102.2.4) ROOF COVERINGS ON | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | SHALL CONFORM TO THE REQUIREMENTS OF | | CLASS A OR B ROOF COVERINGS, AS DEFINED | | IN FBC 1505.ANNOTATE THE PLANS TO | | DEMONSTRATE COMPLIANCE. | | | | 6) SUBMIT PRODUCT APPROVALS FOR THE NEW | | WINDOWS AND GLASS BLOCK AND FOR EXTERIOR | | DOORS 101, 105, 106 AND 207. | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | PRODUCT APPROVAL NUMBER (FL###), | | AVAILABLE FROM THE DEPT OF COMMUNITY | | AFFAIRS PRODUCT APPROVAL WEBSITE | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | 7) PRODUCT APPROVAL.RULE 9B-72 FAC. | | FOR PRODUCTS WHICH DO NOT HAVE STATEWIDE | | PRODUCT APPROVAL, LOCAL PRODUCT APPROVAL | | CAN BE ACHIEVED IF THERE IS A QUALITY | | ASSURANCE PROGRAM IN PLACE WITH A STATE | | APPROVED QUALITY ASSURANCE ENTITY.IF | | NEITHER IS APPLICABLE, THEN SITE | | SPECIFIC APPROVAL IS REQUIRED.LOCAL | | PRODUCT APPROVAL WILL ALLOW A PRODUCT TO | | BE USED, IN ACCORDANCE WITH THE TEST | | CRITERIA, THROUGHOUT THE JURISDICTION OF | | WEST PALM BEACH.SITE SPECIFIC PRODUCT | | APPROVAL WILL ALLOW A PRODUCT TO BE | | USED ONLY ON THE PROJECT FOR WHICH THAT | | SITE SPECIFIC APPROVAL IS GRANTED. | | LOCAL AND SITE SPECIFIC PRODUCT APPROVAL | | APPLICATION FORMS ARE AVAILABLE FROM | | THIS OFFICE.APPROVED QUALITY ASSURANCE | | ENTITIES ARE LISTED ON THE DCA WEBSITE: | | WWW.FLORIDABUILDING.ORG/COMMON/C_ORG_ | | REGI_SRCH.ASP | | | | 8) TO EXPEDITE REVIEW OF A RESUBMITTAL | | WHICH REQUIRES NEW PLANS IN ORDER TO | | ADDRESS THE ABOVE COMMENTS, THE OLD | | SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | REMAINING OLD SHEETS, TO FORM A SET OF | | 'OLD/VOID SHEETS', FOR COMPARISON OF | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | PLANS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2005-01-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-01-20 |
Time |
10:26 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-01-20 |
Time |
10:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2005-01-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-01-19 |
Time |
17:16 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-01-19 |
Time |
17:16 |
Sent To |
|
|
Notes |
2005-01-19 00:00:00 | *********** UNSAT ************* | | | | 1)NOTE: PLEASE SEE SHEET E0.0 IN SECOND | | SET IS A PHOTOCOPY OF SIGNED AND SEALED | | PLANS. | | MUST BE ORIG SIGNED AND SEALED FOR | | SECOND SET. FS 471.023 | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2004-12-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-12-21 |
Time |
13:34 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-12-21 |
Time |
13:34 |
Sent To |
|
|
Notes |
2004-12-21 00:00:00 | *********** UNSAT *************** | | | | PLEASE SEE NOTES FROM PREVIOUS TWO | | REVIEWS. | | | | 1)NOTE: PLEASE SEE ELEVATOR DISC IS | | STILL BEING SHOWN AS 100A WITH A 150A | | FEED.?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-10-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-06 |
Time |
15:43 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2004-10-06 |
Time |
15:43 |
Sent To |
|
|
Notes |
2004-10-06 00:00:00 | ********PROVISO/REVISION ************* | | | | 1)NOTE: PLEASE SEE ELEVATOR DISCONNECT | | IS STILL SHOWN AS 100A W/ A 150A FEED. | | THIS DISCONNECT MUST BE RATED AT 150A'S | | AND MAY HAVE THE 100A FUSES AS NOTED. | | THIS HAS BEEN REDLINED ON PLANS. | | PLEASE REVISE BEFORE ROUGH ELECTRICAL | | INSPECTION. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-08-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-27 |
Time |
14:42 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2004-08-27 |
Time |
14:42 |
Sent To |
|
|
Notes |
2004-08-27 00:00:00 | ******** UNSAT ******** | | | | 1)NOTE: PLEASE PROVIDE WIND LOADING FOR | | LT POLE TO FBC 140. | | THIS INFORMATION SHOULD BE REFERENCED ON | | ELECTRICAL PLANS AND/OR STRUCTUAL/ARCH | | SHEETS. | | | | 2)NOTE: PLEASE SEE 700.16 FOR ELECTRICAL | | /ELEVATOR MACHINE RM. | | | | 3 )NOTE: PLEASE SHOW LOAD CALCULATIONS, | | PLEASE SHOW PER | | 220.3,220.10,220.11,220.13 ETC. | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | AT 125% PER 215.3,230.42 | | | | 4)NOTE: PLEASE SEE ELEVATOR MAIN DISC | | IS SHOWNAS 100A'S AND YET SEEMS TO BEING | | FED W/ 150A BRKR? | | PLEASE VERIFY AND CORRELATE. | | 215.5 | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | INSERT ONLY NEW SHEETS INTO COMPLETE | | SETS FOR REVIEW AND STAMPING. | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | REVIEWERS WHICH MAY HAVE AN AFFECT ON | | ELECTRICAL PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2004-12-20 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2004-12-20 |
Time |
13:39 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2004-12-20 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2004-08-23 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2004-08-23 |
Time |
13:34 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2004-08-23 |
Time |
13:34 |
Sent To |
|
|
Notes |
2004-08-23 00:00:00 | PASSED WITH PROVISOS: | | 1. ANY WORK WITHIN PUBLIC R.O.W WILL | | REQUIRE A SEPARATE PERMIT FROM PUBLIC | | UTILITIES AND ENGINEERING; 949-1086 | | WINDELL PALMER. | | 2. APPROACHES (TURN OUTS) MUST BE | | CONSTRUCTED PER CITY OF WEST PALM BEACH' | | STANDARD AND REQUIREMENTS. | | 3. ANY NEW CONNECTION TO CITY SERVICES | | MUST BE APPROVED BY THE PUBLIC UTILITIES | | AND ENGINEERING; 949-1085 MANNY GONZALEZ | | 4. POLLUTION/ EROSION PLANS MUST BE | | INSTALLED PRIOR TO ANY CONSTRUCTION AND | | MAINTAINED DURING. | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2004-12-21 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-12-21 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-12-21 |
Time |
12:53 |
Sent To |
|
|
Notes |
2004-12-21 00:00:00 | 1. ENSURE THAT EMERGENCY LIGHTING | | IS AVAILABLE TO DIRECT PERSONS | | DOWN SECOND FLOOR STAIRS. | | | | 2. ENSURE BUILDING ADDRESS IS MOUNTED | | ON PROPER ELEVATION. A MINIMUM OF | | 6" NUMBERS REQUIRED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-10-08 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2004-10-08 |
Time |
13:41 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2004-10-08 00:00:00 | PLANS WERE REVIEWED WITH MIKE CARSILLO | | ON CONFERENCE CALL LM |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-09-01 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-09-01 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-09-01 |
Time |
11:41 |
Sent To |
|
|
Notes |
2004-09-01 00:00:00 | **********DENIED************************ | | | | 1) EXTERIOR STAIRS ALL OPENINGS WITHIN | | 10 FEET SHALL BE 1 HOUR FIRE RATED. ON | | SHEET LS-1 SHOWS OPENINGS WITHIN 10 FEET | | TO THE RIGHT APPEARS NOT TO BE 1 HOUR | | FIRE RATED. | | | | 2) INTERIOR WALL AND CEILING FINISH | | SHALL COMPLY WITH CH. 38.3.3.2. | | | | 3) BUILDING ADDRESS IS REQUIRED. | | | | 4) SEPARATE PLANS AND PERMIT APPLICATION | | ARE REQUIRED FOR THE FIRE ALARM SYSTEM. | | | | NATE MCCRAY, CAPTAIN | | 835-2910 OR 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2005-06-02 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2005-06-02 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2005-06-02 |
Time |
14:35 |
Sent To |
|
|
Notes |
2005-06-02 00:00:00 | GIVEN TO RON REGUEIRO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-04-26 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2005-04-26 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-04-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-22 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-22 |
Time |
15:08 |
Sent To |
M |
|
Notes |
2005-04-22 00:00:00 | TO "PKRAUSS" DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-04-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-18 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
|
Time |
|
Sent To |
M |
|
Notes |
2005-04-18 00:00:00 | TO "M" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-01-18 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-18 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-18 |
Time |
13:08 |
Sent To |
|
|
Notes |
2005-01-18 00:00:00 | TO "COMM BD#33/ REV. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-12-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-08 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-08 |
Time |
09:10 |
Sent To |
|
|
Notes |
2004-12-08 00:00:00 | SENT TO "COMM BD#9" /REV. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-12-07 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-07 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-07 |
Time |
16:03 |
Sent To |
B |
|
Notes |
2004-12-07 00:00:00 | SENT TO "RB" DESK./SUBMITTALS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-10-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-04 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-04 |
Time |
11:43 |
Sent To |
|
|
Notes |
2004-10-04 00:00:00 | TO COMM BD#37 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-09-15 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-26 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-08-20 |
Time |
12:29 |
Sent To |
|
|
Notes |
2004-08-20 00:00:00 | TO COMM BD#62 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2005-06-02 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2005-06-02 |
Time |
15:03 |
Rev Time |
0.33 |
Received By |
rregueir |
Date |
2005-06-02 |
Time |
15:01 |
Sent To |
|
|
Notes |
2005-06-02 00:00:00 | SUBMITTAL RECEIVED FOR CURB EXTENSIONS | | RAISING ROOFTOP EQUIPMENT. | | | | RONALD J REGUEIRO | | 561-805-6734 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2005-04-26 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-04-26 |
Time |
10:04 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2005-04-26 |
Time |
10:04 |
Sent To |
|
|
Notes |
2005-04-26 00:00:00 | AS-BUILT DRAWINGS |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2005-04-22 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-04-22 |
Time |
16:07 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2005-04-22 |
Time |
16:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2005-04-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-04-19 |
Time |
09:58 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2005-04-19 |
Time |
09:57 |
Sent To |
|
|
Notes |
2005-04-19 00:00:00 | DENIED: | | RETURN AIR FROM ROOM 110 AND 105 ARE NOT | | SIZED IN ACCORDANCE WITH 2001 FBC/M | | 601.4 EXCEPTION #1.RETURN TRANSFER | | PLENUMS SHALL BE 1 1/2 TIMES THE SQUARE | | INCHES OF THE SUPPLY AIR INTO THAT | | SPACE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-12-21 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-12-21 |
Time |
07:52 |
Rev Time |
2.00 |
Received By |
pkrauss |
Date |
2004-12-21 |
Time |
06:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-09-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-09-15 |
Time |
11:18 |
Rev Time |
1.10 |
Received By |
pkrauss |
Date |
2004-09-15 |
Time |
09:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-12-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-12-21 |
Time |
18:13 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-12-21 |
Time |
18:13 |
Sent To |
|
|
Notes |
2004-12-21 00:00:00 | REVISION OK - CHANGED THE CONDENSATE | | PIPING AND LOCATION OF THE DRYWELL - | | REMOVED DRYWELL LOCATIONS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-10-08 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-10-08 |
Time |
14:21 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-10-08 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-09-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-08-28 |
Time |
15:30 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-08-28 |
Time |
15:30 |
Sent To |
|
|
Notes |
2004-08-28 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | | | 1) SHTS A1-1 & A1-2 SUBMIT A DETAIL FOR | | TOILET ROOMS SHOWING COMPLIANCE WITH | | SECTIONS 11-4.16, 11-4.19, & 11-4.22 & | | ALL SUBSECTIONS. SHOW MEASUREMENTS TO | | THE CENTER OF THE W/C OFF THE WALL AND | | THE CENTER OF LAV OFF WALL. SEE FIG 28 | | FOR THE W/C AND LAV MIN. 15" TO CENTER | | ON CLEAR FLOOR SPACE. | | 2) SHTS A1-1 & A1-2 SUBMIT A DETAIL FOR | | DRINKING FOUNTAINS SHOWING COMPLIANCE | | WITH SECTION 11-4.15. | | 3) COMMENT ADDRESSED ON PERMIT 04081108 | | 4) COMMENT ADDRESSED ON PERMIT 04081108 | | 5) SHT A2-2 DETAILS 04 & 08 SHOW HEIGHT | | AND WIDTH FOR SCUPPERS AND OVERFLOW | | SCUPPERS. SECTION 104.2.1 | | 6) SHT PO.1 GENERAL SPECIFICATIONS #24, | | AIR CHAMBERS ARE NOT APPROVED. DELETE | | REFERENCE. SECTION 604.9 | | 7) IN THE REMOVAL OF ANY PARY OF A | | DRAINAGE SYSTEM, DEAD ENDS SHALL BE PRO- | | HIBITED. SECTION 704.5 - ALL CAPPED PIP- | | ES SHALL BE CAPPED WITH A PERMINATE CAP | | 8) SHT P2.2 WATER RISER DIAGRAM, AIR | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | THE RISER DIAGRAM. IS WATER HAMMER ARR- | | ESTORS ARE INSTALLED THEY SHALL BE LOCA- | | TED NEAR THE FIXTURE IN AN "EFFECTIVE | | RANGE" NOT IN THE CEILING. PDI-WH 201. | | 9) SHT P3.1 TANKLESS WATER HEATERS SHALL | | BE LISTED. SUBMIT MANUF. SPECIFICATIONS | | SECTION 303.4 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-26 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-08-26 |
Time |
16:07 |
Sent To |
|
|
Notes |
2004-08-26 00:00:00 | APPROVED BY SHIRLEY GRAHAM, PLANNER | | 822-1458 MM |
|
|