Plan Review Details - Permit 04080974
Plan Review Stops For Permit 04080974
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-11-24 Cont ID  
Sent By lsmith Date 2004-11-24 Time 09:27 Rev Time 0.50
Received By lsmith Date 2004-11-24 Time 09:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-10-29 Cont ID  
Sent By lsmith Date 2004-10-29 Time 14:42 Rev Time 0.50
Received By lsmith Date 2004-10-29 Time 14:42 Sent To P
Notes
2004-10-29 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1.PLANS MUST SHOW METHOD OF
 COMPLIANCE TO FLA. POOL SAFETY ACT FBC
 424.2.7.17.1-THRU 424.2.7.17.3.
  
 2. VALUE HAS BEEN ADJUSTED PER MARSHALL
 SWIFT COST GUIDE. ADDITIONAL FEES DUE.
  
 3. A NOTICE OF COMENCEMENT MUST BE
 FILED AT THE COUNTY CLERK OFFICE AND A
 COPY SUBMITTED BEFORE A PERMIT CAN BE
 ISSUED.
  
 ANY QUESTIONS PLEASE CALL
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2004-11-18 Cont ID  
Sent By btrobaug Date 2004-11-18 Time 16:10 Rev Time 0.33
Received By btrobaug Date 2004-11-18 Time 15:58 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-08-25 Cont ID  
Sent By csiegber Date 2004-08-24 Time 15:59 Rev Time 0.33
Received By btrobaug Date 2004-08-25 Time 12:48 Sent To P
Notes
2004-08-25 00:00:00 
 PLEASE SUBMIT DETAILS FOR THE PANEL
 SHOWN ON THE SCHEMATIC, FEEDER AND
 CONDUIT SIZE AND TYPE, PANEL RATING AND
 OCP, PANEL SCHEDULE AND COMPUTED LOAD,
 ETC.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-11-10 Cont ID  
Sent By csiegber Date 2004-11-10 Time 13:42 Rev Time 0.00
Received By csiegber Date 2004-11-10 Time 13:41 Sent To E
Notes
2004-11-10 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-11-01 Cont ID  
Sent By csiegber Date 2004-11-01 Time 09:05 Rev Time 0.00
Received By csiegber Date 2004-11-01 Time 09:05 Sent To P
Notes
2004-11-01 00:00:00TO KS DESK/PER BS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-24 Cont ID  
Sent By csiegber Date 2004-08-24 Time 15:59 Rev Time 0.00
Received By csiegber Date 2004-08-24 Time 15:59 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-20 Cont ID  
Sent By mmclean Date 2004-08-24 Time 11:02 Rev Time 0.00
Received By csiegber Date 2004-08-20 Time 12:17 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-11-22 Cont ID  
Sent By kstevens Date 2004-11-22 Time 14:16 Rev Time 0.50
Received By kstevens Date 2004-11-22 Time 14:16 Sent To B1
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-11-01 Cont ID  
Sent By lsmith Date 2004-10-29 Time 14:55 Rev Time 1.00
Received By kstevens Date 2004-11-01 Time 10:32 Sent To  
Notes
2004-11-01 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING
 POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS,
 OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW.
 1) FBC-2001424.2.6.6.2 SHOW
 COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE
 MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO
 NOTES)
 2) INDICATE MAXIMUM LENGTH TO VENT LINE
 CONNECTION.
 3) FBC-2001424.2.6.6.4 MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR EA
 PUMP. SEPARATED BY A MINIMUM OF 3 FEET
 OR LOCATED ON TWO DIFFERENT PLANES.
 (DETAIL)-THE PIPING SCHEMATIC SHOWS NO
 MINIMUM MEASURMENT. PLEASE INDICATE THE
 MINIMUM MEASURMENT ON PLANS. SECTION
 104.2.1.
 4) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 5) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 6) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE
 PLANS
 AND PERMIT REQUIRED.
 7) VACUUM LINE NOT SHOWN ON POOL LAYOUT
 SHEET. THIS IS SHOWN ON THE PIPING
 DIAGRAM. PLEASE CLARIFY AND CORRELATE
 PLANS. SECTION 104.2.1
 8) NOTE STATES HEATER IS EXCEMPT FROM
 STATE ENERGY CODE. GAS HEATERS ARE NOT
 90% EFFECIENT. DELETE NOTE. SECTION
 104.2.1
 9) PIPING SCHEMATIC SHOWS A 109K HEAT
 PUMP, BUT POOL EQUIPMENT INDICATES A
 400K NATURAL GAS POOL HEATER. PLEASE
 CLARIFY, AND CORRELATE PLANS. SECTION
 104.2.1
 10)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-24 Cont ID  
Sent By csiegber Date 2004-08-20 Time 12:17 Rev Time 0.00
Received By mmclean Date 2004-08-24 Time 11:02 Sent To I
Notes
***NONE***