Plan Review Stops For Permit 04080887 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-15 |
Time |
14:52 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-08-15 |
Time |
14:52 |
Sent To |
|
|
Notes |
2006-08-15 00:00:00 | INTERIOR CLOSET REV, STUDYAND GARAGE | | OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-12-17 |
Time |
15:02 |
Rev Time |
1.50 |
Received By |
alange |
Date |
2004-12-17 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-12-13 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-12-13 |
Time |
09:02 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2004-12-13 |
Time |
08:51 |
Sent To |
|
|
Notes |
2004-12-13 00:00:00 | DENIED | | | | 4.PRODUCT APPROVALS MISSING FOR | | ROOFING. | | WINDOW AND DOOR PRODUCT APPROVALS HAVE | | ONLY THE QUALITY ASSURANCE SUBMITTED. | | MIAMI-DADE FOR EXAMPLE. | | SUBMIT THE FOLLOWING WITH ALL PRODUCT | | APPROVALS. | | | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | ANY QUESTIONS CALL ME. | | | | ART LANGE | | BUILDING PLANS EXAMINER\ | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-10-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-08-28 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2004-08-28 |
Time |
08:50 |
Sent To |
|
|
Notes |
2004-10-14 00:00:00 | DENIED | | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 3.905.2.1 APPROVED SINGLE-STATION OR | | MULTIPLE STATION SMOKE DETECTORS SHALL | | BE INSTALLED IN ACCORDANCE WITH NFPA | | 72,CHAPTER 2, WITHIN EVERY DWELLING | | UNITWITHIN AN APARTMENT HOUSE, | | CONDOMINIMUM,OR TOWNHOUSE AND EVERY | | GUEST OR SLEEPINGROOM IN A MOTEL, | | HOTEL, OR DORMITORY & | | SLEEPING ROOMS IN RESIDENTIAL CARE/ | | ASSISTED LIVING OCCUPANCIES. WHERE MORE | | THAN ONE DETECTOR IS REQUIRED TO BE | | INSTALLED WITHIN INDIVIDUAL DWELLING | | UNIT, THE DETECTOR SHALL BE WIRED IN | | SUCH A MANNER THAT THE ACTUATION OF ONE | | ALARM WILL ACTIVATE ALL THE ALARMS IN | | THE INDIVIDUAL UNIT. | | | | 4.PRODUCT APPROVALS MISSING FOR | | GARAGE DOORS, ROOFING AND STRAPS AND | | TIE-DOWNS. | | THE FOLLOWING IS REQUIRED FOR ALL THE PR | | ODUCT APPROVALS. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | ART LANGE | | BUILDING PLAN REVIEW | | TEL: (561)805-6672 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-09-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-30 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-30 |
Time |
18:22 |
Sent To |
PC |
|
Notes |
2006-09-30 00:00:00 | REV OK, STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2006-09-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-20 |
Time |
18:37 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-20 |
Time |
18:28 |
Sent To |
PC |
|
Notes |
2006-09-20 00:00:00 | *** UNSAT *** | | | | 1) NOTE: PLEASE SEE PLANS STILL SHOW AN | | INDIVIDUA METER ALONG WITH TWO MAINS | | WHICH IS HOW THE ORIGINAL RISER WAS | | SHOWN. IF THIS EQUIPMENT IS A METER/MAIN | | COMBO PANEL, THEN PLANS SHOW THIS ON | | PLANS ON THE SIDE OF THE DWELLING. | | 106.1.2 FBC. | | | | 2) NOTE: PLEASE SEE LOAD CALCULATIONS | | AND PLEASE SEE NEC 220.31. | | PLEASE SEE A/C LOADS MAY NOT BE DE-RATED | | IN WITH GEN LTS AND RECEPTS. A/C LOAD IS | | CURRENLTY BEING DE-RATED AT 65% AND THEN | | AGAIN AT 40%. | | PLEASE KNOW, BASED ON THE LOADS ON | | PANELS, THE LOAD FOR THE SERVICE IS | | SUBSTANTIALLY HIGHER THAN THE LOAD | | SHOWN. | | | | 3) NOTE: PLEASE SEE MISSIGN RECEPT IN | | BEDRM #4. | | MORE THAN 2' OF WALL REQUIRES A RECEPT. | | 210.52 | | | | 4) NOTE: PLEASE SEE 210.8A7, PLEASE SEE | | ANY RECEPT WITHIN 6FT OF THE SINK'S EDGE | | IN THE LAUNDRY RM IS REQUIRED TO BE GFI | | / GFI PROTECTED. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-11 |
Time |
18:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-11 |
Time |
15:13 |
Sent To |
B |
|
Notes |
2006-08-11 00:00:00 | ********* UNSAT ********* | | | | ** PLEASE SEE SOME ITEMS ARE THE SAME AS | | COMMENTS WHICH WERE REDLINED ON PLANS IN | | "NOV 04". | | PLEASE ALSO SEE NEW COMMENTS AS PLANS | | HAVE BEEN REVISED. | | | | 1) NOTE: PLEASE SEE MIN GEC PER 250.66/ | | 310.15B6AS 1/0. THIS SIZE WAS REDLINED | | ON ORIGINAL PLANS. | | | | 2) NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTORS FROM THE MAINS TO | | THE SUBPANELS. | | 250.110.,250.24B,250.122 ETC. | | | | 3) NOTE: PLEASE CORRELATE PLANS WITH | | RISER. PLEASE SEE RISER NOW SHOWS WHAT | | APPEARS TO BE A METER/MAIN COMBO, YET | | NOT CLEAR AS NO MAIN IS SHOWN?? | | PLEASE SEE 230.70, PLEASE SEE PLANS | | STILL SHOWS TWO MAIN DISCONNECTS AS ON | | ORIG RISER. PLEASE SEE PLANS ARE NOT | | CLEAR FOR THE SCENARIO . WHERE IS THE | | OCP FOR PANEL "B", IS THERE FEED-THRU | | LUGS? ETC ETC. | | | | 4) NOTE: PLEASE SEE LOAD CALCULATIONS | | ARE NOT COMPLETE FOR ALL EQUIPMENT AND | | FOR SERVICE. PLEASE SEE NEC 220.31 ETC | | AS LOADS ARE NOT COMPLETED, A/C LOADS | | ARE NOT SHOWN IN CALCS WHICH MAY NOT BE | | DERATED WITH THE GEN LT/RECEPTS. | | PLEASE SEE LOADS FOR PANEL "B" ARE NOT | | SHOWN IN WITH THE OTHER. ETC. | | 408.4,310.16,240.4 230.70. | | | | 5) NOTE: PLEASE SEE MISSING REDLINED | | RECEPTS ON PLANS PER 210.52 | | | | 6) NOTE: PLEASE SEE MISSING POOL PANEL | | ON PLANS WHICH IS SHOWN ON RISER. | | FBC 106.1.2 ADMIN SECT. | | | | 7) NOTE: PLEASE SEE DISCONNECT | | CLEARENCES PER 110.26 FOR ALL | | DISCONNECTS. PLEASE SEE A/C EQUIPMENT | | SIDE OF HOUSE. | | | | 8) NOTE: PLEASE SEE PLANS NOW INCLUDE | | ALL NEW LV SKR WIRINGAND SPKRS WHICH | | WERE NOT ON ORIGINAL PLANS OR PERMIT. | | PLEASE SUBMIT THIE UNDER A SEPARATE | | PERMIT APPLICATION, PLANS AND FEES FOR | | COMPLETE SCOPE OF WORK. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-11-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-11-29 |
Time |
10:32 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-11-29 |
Time |
09:33 |
Sent To |
M |
|
Notes |
2004-11-29 00:00:00 | ******** NOTES REDLINED ********* | | | | PLEASE SEE SOME ITEMS ON FIRTS REVIEW. | | | | 1)NOTE: PLEASE SEE GEC IS SHOWN AS #1, | | WHEN 250.66 REQUIRES 1/0, REDLINED. | | | | 2)NOTE: PLEASE SEE A GEC/EQUIPMENT | | GROUNDING CONDUCTOR IS BEING SHOWN FROM | | METER TO FIRST MEANS OF DISCONNECT. | | PLEASE SEE 250.6, 250.24 THIS IS NOT | | PERMITTED TO BE INSTALLED. | | | | 3)NOTE: REDLINED SD'S TO BE ADDED INSIDE | | AND OUTSIDE "STUDY"THIS IS CONSIDERED TO | | BE AN ADAPTABLE SLEEPING ROOM WITH THE | | ADDED CLOSET. | | | | 4)NOTE: PLEASE SEE SOME RECEPTS MISSING | | PER 210.52 | | | | | | **** PLEASE SEE PLANS HAVE BEEN REDLINED | | WITH MOST OF THE ABOVE AND NEED TO BE | | REVISED WHEN ANY OTHER REVISIONS ARE | | SUBMITTED BEFORE ROUGH. **** |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-08-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-25 |
Time |
08:43 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2004-08-25 |
Time |
08:43 |
Sent To |
M |
|
Notes |
2004-08-25 00:00:00 | ************* UNSAT ***************** | | | | 1)NOTE: SMOKE DETECTORS ARE REQUIRED | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | UNIT. | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | TO FLOORS ABOVE AND IN THE VICINITY OF | | BEDROOMS. | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | A MIN OF 3' FROM BATHROOM DOORS AND | | KITCHENS. | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | * PLEASE EITHER ADD A SD IN WHAT APPEARS | | TO BE MASTER BEDRM OR MOVE ONE SHOWN | | IN HALLWAY INTO MASTER SLEEPING AREA. | | *PLEASE SEE MISSING SD ON FIRST FLR | | LEADING TO FLR ABOVE. | | | | 2)NOTE: PLEASE PROVIDE ROOM DESIGNATION | | ON ELECTRICAL PLANS. | | | | 3)NOTE: PLEASE SEE 210.52D FOR MISSING | | GFI ON FIRST FLR BATH. | | | | 4)NOTE: PLEASE SEE 210.52C3 FOR KITCHEN | | PENINSULAR. A RECEPT IS SHOWN BUT W/ | | OVERHANG OF KITCHEN COUNTERTOP THIS | | MAY NOT BE ABLE TO SERVE COUNTERSPACE. | | PLEASE ALSO SEE WALL SPACE AT SAME | | LOCATION PER 210.52 | | | | 5)NOTE: PLEASE SEE 210.52 FOR A FEW | | RECEPTS MISSING. 2' OF WALL SPACE ETC. | | | | 6) NOTE: PLEASE SHOW ALL RECEPTS SERVING | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | -ED PER 210.8A-6 | | **ISLAND** | | | | 7 )NOTE: PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CURCUIT(S) ON PANEL | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | IN BEDROOMS ARE TO BE PROTECTED , | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | 210.12B 2002 NEC.PLEASE SEE CIRCUITING | | | | 8)NOTE: PLEASE SEE RISER SHOWS AN | | EQUIPMENT FROM GUTTER TO MAINS/FIRST | | MEANS OF DISC. PLEASE SEE 250.24,250.6 | | AN EG IS NOT INSTALLED UNITL AFTER THE | | FIRST MEANS OF DISC. | | | | 9)NOTE: PLEASE SEE LOCATION OF SERVICE | | SHOWN ON PLANS. RISER SHOWS METER/GUTTER | | AND TWO MAIN DISC'S WHICH DO NOT APPEAR | | TO BE ABLE TO FIT IN LOCATION SHOWN. | | PLEASE SEE 110.26 | | | | 10)NOTE: PLEASE CLARIFY LOCATION ON | | SECOND FLR WHICH APPEARS TO HAVE BATH | | RM SHOWN WITH NO ELECTRICAL? ARE THESE | | RMS BEING BUILT AT THIS TIME? | | LTS ETC. 210.582,210.70 | | | | 11)NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | PLEASE SEE LOAD CALCULATIONS ARE NOT | | SHOWN PER 220.31 . IT HAS BEEN NOTED | | THAT LIGNING IS BEING SHOWN AS A CONNECT | | -ED LOAD. PLEASE VERIFY WATTAGE OF | | FIXTURES AND PLEASE SEE FBC FOR REQUIRED | | "AIR-LOCK" TYPE FIXTURES. NOTE: MOST | | OF THESE TYPE OF FIXTURES ARE A MAX OF | | 75W. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-10-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-10 |
Time |
19:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-10 |
Time |
19:55 |
Sent To |
P |
|
Notes |
2006-10-10 19:55:57 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-09-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-26 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-26 |
Time |
10:43 |
Sent To |
E |
|
Notes |
2006-09-26 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-09-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-14 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-14 |
Time |
10:37 |
Sent To |
E |
|
Notes |
2006-09-14 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-08-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-10 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-10 |
Time |
10:33 |
Sent To |
E |
|
Notes |
2006-08-10 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-11-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-11-23 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-11-23 |
Time |
12:43 |
Sent To |
E |
|
Notes |
2004-11-23 00:00:00 | SENT TO "DP"DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-10-14 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-24 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2004-08-19 |
Time |
15:56 |
Sent To |
|
|
Notes |
2004-08-24 00:00:00 | TO SFD RACK/E | 2004-08-19 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-12-04 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2004-12-04 |
Time |
|
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2004-12-04 |
Time |
|
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-08-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-25 |
Time |
08:43 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2004-08-28 |
Time |
07:26 |
Sent To |
P |
|
Notes |
2004-08-28 00:00:00 | DENIED: | | 1.PLEASE PROVIDE ENERGY AND MANUAL J | | CALCULATIONS IN ACCORDANCE WITH 2002 FBC | | CHATPER 13 SUB-CHAPTER 6. | | | | 2. AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED PER 2001 FBC(M) | | 307.2.3. | | | | 3.A MINIMUM OF 4" AROUND THE AHU IS | | REQUIRED PER 2001 FBC(M) 603.1.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-08-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-08-28 |
Time |
07:26 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2004-08-28 |
Time |
11:38 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-08-24 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-24 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-08-24 |
Time |
09:16 |
Sent To |
I |
|
Notes |
2004-08-24 00:00:00 | MUST PULL SEPARATE PERMIT FOR POOL/SPA & | | DECK. |
|
|