Plan Review Stops For Permit 04080780 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-02-16 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2005-02-16 |
Time |
11:16 |
Rev Time |
1.50 |
Received By |
lsmith |
Date |
2005-02-16 |
Time |
11:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-01-05 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2005-01-05 |
Time |
15:03 |
Rev Time |
1.00 |
Received By |
lsmith |
Date |
2005-01-05 |
Time |
15:03 |
Sent To |
|
|
Notes |
2005-01-05 00:00:00 | BUILDINIG PLAN REVIEW: FAILED | | | | 1. THE OWNER/AGENT STILL HAS NOT SIGNED | | THE ENERGY FORM. | | | | 2.THE DADE COUNTY PRODUCT APPROVAL FOR | | THE ARCH WINDOWS FOR THE BUTT GLASS | | ASSEMBLY NEEDS TO BE SUBMITTED. THE | | GLASS IS NOT IMPACT AND WILL REQUIRE | | STORM PANEL PROTECTION. ACCORDING TO | | THE | | ENGINEER THE ARCH 4500 SERIES WINDOWS | | ARE TO BE USED IN THIS ASSEMBLY. | | | | 3. THE APPLICATION FOR THE SITE | | SPECIFIC | | PRODUCT APPROVAL IS INCOMPLETE FOR THE | | BUTT GLASS WINDOWS.THE ENGINEER CANNOT | | BE THE TECHNICAL REPRESENTATIVE (6) AND | | (7) APPROVED THIRD PARTY QUALITY | | ASSURANCE ENTITY LISTED WITH THE STATE. | | THIS IS A CONFLICT OF INTEREST. THE | | DADE | | COUNTY PRODUCT APPROVAL FOR THE ARCH | | 4500 SERIES SHOULD BE SUBMITTED WITH | | THE | | SITE SPECIFIC APPLICATION. | | | | 4. THERE IS STILL A BALANCE OF $753.65 | | IN PERMIT FEES DUE. | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-08-31 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-08-28 |
Time |
11:04 |
Rev Time |
2.50 |
Received By |
lsmith |
Date |
2004-08-31 |
Time |
09:21 |
Sent To |
|
|
Notes |
2004-08-31 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | 1. ENERGY FORMS ARE NOT SIGNED BY | | OWNER/AGENT. | | | | 2. SUBMIT PRODUCT APPROVALS FOR BUTT | | GLASS ASSEMBLY. SUBMIT ENGINEERING FOR | | BUTT GLASS ASSEMBLY.AN INSPECTION | | MUSTBE DONE BY THE ENGINEER WHEN THE | | BUTT | | GLASS IS INSTALLED.A LETTER STATING | | IT IS INSTALLED PER HIS DRAWINGS MUST | | BE SUBMITTED BEFORE A C/O. | | | | 3. PLANS MUST BE TAKEN TO PBC AND IMPACT | | FEES PAID, PLANS STAMPED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 4. THE CALCULATED VALUE IS UNDERSTATED. | | ADDITIONAL PERMIT FEES ARE DUE. | | | | 5. A NOTICE OF COMMENCEMENT MUST BE | | FILED AT THE COUNTY CLERKS OFFICE | | BEFORE A PERMIT CAN BE ISSUED. | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
F |
Date |
2006-09-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-26 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-26 |
Time |
12:15 |
Sent To |
PC |
|
Notes |
2006-09-26 00:00:00 | ** UNSAT ** | | | | 1) NOTE: PLEASE SEE ONLY ONE SET OF | | PLANS IS SIGNED , DATED AND SEALED. | | PLEASE SUBMIT OTHER SIGNED AND SEALED | | SHEET. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-08 |
Time |
21:22 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-08 |
Time |
21:22 |
Sent To |
PC |
|
Notes |
2006-08-08 00:00:00 | REVISED RECEPTS LOCATIONS ETC. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2006-04-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-04-21 |
Time |
17:41 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-04-21 |
Time |
17:34 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-04-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-04-04 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-04-04 |
Time |
12:58 |
Sent To |
PC |
|
Notes |
2006-04-04 00:00:00 | PLANS REDLINED, | | | | | | SERVICE CONDUITS FROM METER TO MCB | | PANELS ARE TO BE IN SLAB 230.70 | | | | CIRCUIT FOR UTIL/HALL LTS, SHOWS 15A OCP | | ON #12, WHICH IS OK. | | | | EITHER FOYER OR LIVING ROOM RQUIRES A LT | | FIXTURE OF SOME SORT FOR REQUIRED MEANS | | OF EGRESS LIGHTING. 230.70, LS 101 7.8. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2005-11-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-11-16 |
Time |
19:21 |
Rev Time |
0.40 |
Received By |
dpalmer |
Date |
2005-11-16 |
Time |
19:07 |
Sent To |
M |
|
Notes |
2005-11-16 00:00:00 | REDLINED POSSIBLE MISSING RECEPTS PER | | 210.52,210.52C1 | | | | REDLINED, PLANS SHOW MAIN DISCONNECT | | LOCATED OUTSIDE, HOWEVER RISER DOES NOT | | SHOW THIS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-02-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-16 |
Time |
06:26 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-02-16 |
Time |
06:17 |
Sent To |
B |
|
Notes |
2005-02-16 00:00:00 | AIC RATING SHEET ATTACHED TO ELECTRICAL | | PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-12-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-12-27 |
Time |
15:13 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2004-12-27 |
Time |
15:13 |
Sent To |
M |
|
Notes |
2004-12-27 00:00:00 | **** UNSAT **** | | | | PLEASE SEE NOTE #1 FROM PREVIOUS | | REVIEW. | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 | | THIS COULD NOT BE LOCATED ON PLANS. | | | | 2)NOTE: PLEASE SEE NOTICE FOR FS | | 553.80(2)(B) ATTACHED. THIS IS GIVEN AS | | A NOTICE ONLY AT THIS TIME. | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | ONLY INSERT NEW SHEETS INTO TWO COMPLETE | | SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-08-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-23 |
Time |
14:40 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-08-23 |
Time |
14:09 |
Sent To |
M |
|
Notes |
2004-08-23 00:00:00 | ************* UNSAT **************** | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | 3)NOTE: PLEASE SEE LAUNDRY LOAD SHOWN AT | | 1.2KW. PLEASE SEE 220.16 FOR MIN 1.5KW | | | | 4 )NOTE: PLEASE SHOW /CLARIFY METHOD | | OF THE EQUIPMENT GROUNDING BETWEEN | | MAIN MEANS OF DISC AND PANELS. | | 250.110,250.24 | | PLEASE SIZE ALL EQUIPMENT GROUNDING | | CONDUCTORS PER 250.122 | | PLEASE SEE 250.66 FOR SIZING OF GROUND- | | -ING ELECTRODE CONDUCTOR. | | 310.15B6 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2006-09-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-20 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-20 |
Time |
16:26 |
Sent To |
E |
|
Notes |
2006-09-20 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-08-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-08 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-08 |
Time |
16:56 |
Sent To |
E |
|
Notes |
2006-08-08 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-12 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-12 |
Time |
16:30 |
Sent To |
E |
|
Notes |
2006-04-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-04-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-03 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-03 |
Time |
09:12 |
Sent To |
E |
|
Notes |
2006-04-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-03-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-31 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-31 |
Time |
16:34 |
Sent To |
M |
|
Notes |
2006-03-31 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-15 |
Time |
18:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-15 |
Time |
18:02 |
Sent To |
E |
|
Notes |
2005-11-15 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-10-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-06 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-06 |
Time |
16:55 |
Sent To |
M |
|
Notes |
2005-10-06 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-02-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-11 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-11 |
Time |
09:24 |
Sent To |
E |
|
Notes |
2005-02-11 00:00:00 | TO DPALMER DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-12-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-22 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-22 |
Time |
09:01 |
Sent To |
E |
|
Notes |
2004-12-22 00:00:00 | SENT TO "DP" DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-08-31 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-20 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-08-18 |
Time |
12:17 |
Sent To |
|
|
Notes |
2004-08-20 00:00:00 | TO SFD RACK/E | 2004-08-18 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-04-03 |
Time |
12:02 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-04-03 |
Time |
12:02 |
Sent To |
|
|
Notes |
2006-04-03 00:00:00 | REVISION TO MECH. PLANS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2005-11-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-11-17 |
Time |
16:00 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-11-17 |
Time |
16:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2005-10-14 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-10-14 |
Time |
08:54 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2005-10-14 |
Time |
08:54 |
Sent To |
|
|
Notes |
2005-10-14 00:00:00 | *** DENIED *** | | 1) MECHANICAL REVISION PLANS DO NOT | | MATCH ENERGY CALCULATIONS. A/C EQUIP. | | LIST ON PLANS ARE CALLING FOR (1) 4 TON, | | (1) 2 1/2 TON ,AND (1) 1 1/2 TON. ENERGY | | CAL'S. ARE CALLING FOR (1) 3 1/2 TON, | | (1) 2 TON, AND (1) 1 1/2 TON. THEY MUST | | COINCIED. | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-01-05 |
Time |
14:42 |
Rev Time |
0.45 |
Received By |
prafter |
Date |
2005-01-05 |
Time |
14:42 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-08-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-23 |
Time |
14:40 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2004-08-25 |
Time |
10:37 |
Sent To |
P |
|
Notes |
2004-08-25 00:00:00 | PROVISO: | | PER THE REVISED 2001 FBC(M) 601.4 | | AND EXCEPTION #3; BALANCED AIR REQUIRED | | ALL INTO THE MASTER SUITE IS TO BE | | INCLUDED FOR PROPER SIZING OF THE RETURN | | AIR.RETURN AIR SHOULD BE A MINIMUM OF | | 14". | | | | AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED PER 2001 FBC(M) | | 307.2.3. | | | | CONDENSATE SHALL TERMIANTE A MINIMUM OF | | 12" FROM THE BUILDING STRUCTURE.2001 | | FBC 1503.4.4. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-08-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-08-25 |
Time |
10:38 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2004-08-28 |
Time |
11:04 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-08-20 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-20 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-08-20 |
Time |
15:12 |
Sent To |
I |
|
Notes |
|
|