Plan Review Details - Permit 04080738
Plan Review Stops For Permit 04080738
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-10-12 Cont ID  
Sent By shill Date 2004-10-12 Time 08:34 Rev Time 2.00
Received By shill Date 2004-10-12 Time 08:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-09-21 Cont ID  
Sent By shill Date 2004-09-21 Time 13:15 Rev Time 2.00
Received By shill Date 2004-09-21 Time 13:15 Sent To  
Notes
2004-09-21 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)THERE IS A HOLD ON THIS PROPERTY,
 SEE ATTACHED.PLEASE ADDRESS.IF THIS
 HOLD IS FOR THIS ADDRESS, A 4X PERMIT
 FEE IS DUE.IF IT IS NOT FOR THIS
 ADDRESS, APPLY FOR PERMITS AS
 REQUIRED.
  
 2.)GENERAL NOTE #1 REFERS TO THE
 COUNTY; JURISDICTION IS CITY OF WEST
 PALM BEACH.
  
 3.)THE SHEET IS MARKED A2, APPEARS
 THAT IT SHOULD BE A1.
  
 4.)THE APPLICATION STATES "FRAME FOR
 NEW CEILING".PROVIDE A DETAIL.
  
 5.)A CA NUMBER IS REQUIRED ON THE
 PLAN FOR BUNKER ENGINEERING.THE
 PRINTED NAME AND LICENSE NUMBER OF THE
 PERSON SEALING THE DOCUMENT IS TO BE
 ON EACH SHEET.FAC61G15-23.002.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-10-21 Cont ID  
Sent By dpalmer Date 2004-10-21 Time 13:29 Rev Time 0.50
Received By dpalmer Date 2004-10-08 Time 16:56 Sent To  
Notes
2004-10-21 00:00:00************ PROVISO/REVISION *******
  
 1)NOTE: PLEASE SEE THAT THE ELECTRICAL
 SERVICE MUST BE BROUGHT UP TO 2002 NEC.
 PLEASE SEE CHAPTER 34 FBC FOR RENOVATION
 'S TO EXISTING BLGS.
  
 2)NOTE: PLEASE SUBMIT A REVISED RISER
 DIAGRAM FOR REVIEW BEFORE ANY ROUGH
 ELECTRICAL INSPECTION IS CALLED IN.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
2004-10-08 00:00:00IN FOR REVIEW,WAITING FOR CALL BACK
 FROM RICHARD CORDOVEZ IN REFERENCE TO
 4X FEE.
  
 A PROVISO MUST BE GIVEN FOR EXISTING
 SERVICE TO BE FEILD VERIFIED FOR CODE
 COMPLIANCE BEFORE ANY ROUGH INSPECTION.
 SERVICEMUST BE BROUGHT UP TO CODE DUE
 TO EXTENT OF WORK. CHAPTER 34 FBC.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-10-06 Cont ID  
Sent By dpalmer Date 2004-10-06 Time 12:58 Rev Time 0.33
Received By dpalmer Date 2004-10-06 Time 12:58 Sent To  
Notes
2004-10-06 00:00:00********** UNSAT ***********
  
 1)NOTE: PLEASE CORRELATE RISER DIAGRAM
 WITH PANEL SCHEDULE.
 RISER SHOWS A NEW 125A MCB PANEL YET
 PANEL SCHEDULE SUBMITTED IS 150A MCB
 PANEL?
 IS THE PANEL SCHEDULE SUBMITTED FOR THIS
 BUILT OUT AREA?
  
 2)NOTE: PLEASE VERIFY OCP FROM EXISTING
 150A SHOWN FEEDING 125A PANEL??
  
 3)NOTE: PLEASE SEE 210.62,220.12 FOR
 REQUIRED SHOW WINDOW RECEPTS.
  
 4 )NOTE: PLEASE SHOW LOAD CALCULATIONS,
 PLEASE SHOW PER
 220.3,220.10,220.11,220.13 ETC.
 PLEASE ALSO SHOW ALL CONTINOUS LOADS
 AT 125% PER 215.3,230.42
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-09-17 Cont ID  
Sent By dpalmer Date 2004-09-17 Time 07:18 Rev Time 0.25
Received By dpalmer Date 2004-09-17 Time 07:18 Sent To  
Notes
2004-09-17 00:00:00******* UNSAT ****
  
 1)NOTE: PLEASE SEE FAC 61G15-23.002
 PLEASE INCLUDE PRINTED NAME ON TITLE
 BLOCK.
  
 2)NOTE: PLEASE SEE COVER SHEET INDICATES
 AN E-SHEET IN SET, HOWEVER THERE ARE NO
 E-SHEETS IN SETS. PLEASE CLARIFY.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-10-13 Cont ID  
Sent By nmccray Date 2004-10-13 Time 15:45 Rev Time 0.00
Received By nmccray Date 2004-10-13 Time 15:44 Sent To  
Notes
2004-10-13 00:00:00*********PROVISO************************
  
 PLEASE BE AWARE THAT I DIDN'T ASK WHAT
 THE WALLS WERE RATED AT. I ASKED WHAT
 WAS THE INTERIOR FINISH OF THE WALLS AND
 CEILINGS WERE CLASS A, B OR C

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-09-20 Cont ID  
Sent By nmccray Date 2004-09-20 Time 15:35 Rev Time 0.00
Received By nmccray Date 2004-09-20 Time 15:35 Sent To  
Notes
2004-09-20 00:00:00***********DENIED***********************
  
 1) DEMOLITION MUST COMPLY WITH NFPA 241.
  
 2) PLEASE INDICATE LOCATIONS OF EXISTING
 OR NEW EXIT SIGNS AND EMERGENCY LIGHTS.
  
 3) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND CEILINGS.
  
 4) PLEASE INDICATE FIRE EXTINGUISHERS
 LOCATIONS.
  
  
 NATE MCCRAY, CAPTAIN
 561-835-2910 OR 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-28 Cont ID  
Sent By ptjomsto Date 2005-01-28 Time 14:21 Rev Time 0.00
Received By ptjomsto Date 2005-01-28 Time 14:21 Sent To  
Notes
2005-01-28 00:00:00REV/MECH GIVEN TO PATTY

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-10-05 Cont ID  
Sent By csiegber Date 2004-10-05 Time 15:04 Rev Time 0.00
Received By csiegber Date 2004-10-05 Time 15:04 Sent To  
Notes
2004-10-05 00:00:00TO COMM BD#57

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-09-21 Cont ID  
Sent By shill Date 2004-09-21 Time 13:25 Rev Time 0.00
Received By shill Date 2004-08-17 Time 15:04 Sent To  
Notes
2004-08-17 00:00:00TO COMM BD#28

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-10-28 Cont ID  
Sent By kstevens Date 2004-10-28 Time 15:40 Rev Time 1.00
Received By kstevens Date 2004-10-28 Time 15:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-10-21 Cont ID  
Sent By kstevens Date 2004-10-21 Time 15:51 Rev Time 1.00
Received By kstevens Date 2004-10-21 Time 15:51 Sent To  
Notes
2004-10-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 COMMENTS FROM THE PREVIOUS REVIEW HAVE
 NOT BEEN ADDRESSED, OR HAVE NOT BEEN
 ADDRESSED PROPERLY. NUMBER OF PREVIOUS
 REVIEW COMMENTS WILL REMAIN THE SAME TO
 AVOID CONFUSION.
 1) THERE IS MORE WORK SHOWN ON THE PLAN
 THAN IS SHOWN ON THE APPLICATION. PLEASE
 CALRIFY. SECTION 104.2.1
 4) SHOW THE FOLLOWING INFORMATION ON THE
 ACCESSIBLE TOILET DETAIL. 11-4.16.3
 CLEAR FLOOR SPACE, 11-4.19.3 CLEAR FLOOR
 SPACE.
 5) A WATER RISER DIAGRAM IS REQUIRED PER
 SECTION 104.3.1.1. - THE SANITARY RISER
 DIAGRAM SUBMITTED DOES NOT REFLECT THE
 FLOOR PLAN. RISER SHOWS TWO W/C'S AND
 TWO LAV'S, BUT FLOOR PLAN SHOWS ONE W/C
 AND ONE LAV. PLEASE SHOW SECOND TOILET
 ROOM CAPPED OFF. SECTION 104.2.1
  
 *********WHEN RESUBMITTING PLANS********
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-09-16 Cont ID  
Sent By kstevens Date 2004-09-16 Time 17:56 Rev Time 0.50
Received By kstevens Date 2004-09-16 Time 17:56 Sent To  
Notes
2004-09-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA STATUTES
 FLORIDA ADMINISTRATIVE CODE
  
 1) THERE IS MORE WORK SHOWN ON THE PLAN
 THAN IS SHOWN ON APPLICATION. PLEASE
 CLARIFY. SECTION 104.2.1
 2) INDEX OF DRAWINGS SHOWS SHEETS A-1, &
 E-1, BUT THE ONLY SHEET SUBMITTED IS A-2
 PLEASE CLARIFY. SECTION 104.2.1
 3) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. ALSO SEE SECTION 410.1
 4) SHOW THE FOLLOWING INFORMATION ON THE
 ACCESSIBLE TOILET DETAIL. SECTION 11-4.
 16.2 CLEAR FLOOR SPACE, SECTION 11-4.16.
 5 FLUSH CONTROLS, 11-4.19.3 CLEAR FLOOR
 SPACE, & 11-4.19.4 EXPOSED PIPES AND
 SURFACES.
 5) SHT A-2 ACCESSIBLE TOILET DETAIL
 SHOWS 18" MINIMUM CENTER TO CENTER OF
 BETWEEN THE W/C AND LAV. MINIMUM OF 30"
 IS REQUIRED PER SECTION 405.3.1
 6) A SANITARY AND WATER RISER DIAGRAM
 ARE REQUIRED PER SECTION 104.3.1.1
 7) PER SECTION 704.5 NO DEAD ENDS ALLOW-
 ED WHEN REMOVING PIPING FROM THE SANIT-
 ARY SYSTEM. ABANDONED PIPING SHALL BE
 INSPECTED PRIOR TO COVERING.
 8)A PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)/FS 471.025
 INITIALS ARE NOT ACCEPTABLE.
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025 - FULL SIGNATURE REQUIRED.
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]