Plan Review Stops For Permit 04080662 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-01-13 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2005-01-13 |
Time |
15:12 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2005-01-13 |
Time |
15:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-11-24 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-11-24 |
Time |
07:53 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2004-11-24 |
Time |
07:53 |
Sent To |
|
|
Notes |
2004-11-24 00:00:00 | BUILDING PLAN REVIEW: APPROVED NEW POOL | | PLANS SUBMITTED. LS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-10-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-08-23 |
Time |
14:19 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2004-10-21 |
Time |
10:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2005-01-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-01-13 |
Time |
11:58 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-01-13 |
Time |
11:58 |
Sent To |
B |
|
Notes |
2005-01-13 00:00:00 | ******* PROVISO *************** | | | | 1)NOTE: CONTRACTOR REMOVED HEAT PUMP | | FROM PLANS.CALLED ENGINEER TO VERIFY IF | | OK TO REDLINED. | | | | REDLINED OCP SHOWN FOR POOL PUMP AND | | BLOWER. | | | | | | REVISE PLANS BEFORE ROUGH/FINAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2004-11-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-11-23 |
Time |
17:26 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-11-23 |
Time |
17:26 |
Sent To |
P |
|
Notes |
2004-11-23 00:00:00 | ********* UNSAT ********** | | | | 1)NOTE: PLEASE SEE ELECTRICAL WIRING | | DIAGRAM. PLEASE SEE 50A DISC FOR 2HP | | PUMP, AND 30A DISC FOR 1HP BLOWER | | MOTOR. | | THE OCP INDICATED SEEMS TO WAY OVERSIZED | | FOR EQUIPMENT. | | 240.4,430, ETC | | SINCLAIR ENG COMMENTS. | | | | 1)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | FOR ALL NEW LOADS ADDED TO EXISTING | | PANEL. | | THIS SHOULD BE ON A SEPARATE SHEET WITH | | BEING ON REVISED PLANS FOR HOUSE. THE | | LOAD CALCULATIONS WILL BE PART OF THIS | | PERMIT SUBMITTED FOR RECORD WITH THIS | | SET OF PLANS. | | PLEASE BE SURE PERSON RESPONSIBLE FOR | | PLANS PRINTED NAME AND SIGNS PLANS. | | FBC 104.2.1 | | PLEASE SEE FS 481.223 FOR ARCH/DESIGNERS | | AND WORDS TO THAT AFFECT. | | OTHER PLANS COMMENTS. | | | | A RE-SUB FEE WILL NOT BE CHARGED FOR | | ELECTRICAL COMMENTS. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-11-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-11-01 |
Time |
09:51 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-11-01 |
Time |
08:51 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-08-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-25 |
Time |
10:01 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-08-23 |
Time |
10:10 |
Sent To |
P |
|
Notes |
2004-08-23 00:00:00 | | | PLEASE PROVIDE A CALCULATION | | INCLUDING ALL ADDED LOADS IMPOSED,ALL | | EXISTING LOADS AND THE EXISTING OR | | PROPOSED SERVICE SPECIFICATIONS PER | | 215.15. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-01-10 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-10 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-10 |
Time |
16:13 |
Sent To |
E |
|
Notes |
2005-01-10 00:00:00 | TO "DP" DESK./SUBMITTAL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-11-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-11-05 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-11-05 |
Time |
14:09 |
Sent To |
P |
|
Notes |
2004-11-05 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-25 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-25 |
Time |
10:01 |
Sent To |
E |
|
Notes |
2004-10-25 00:00:00 | SENT TO LS FIRST FOR P/THEN TO BT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-08-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-20 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-20 |
Time |
16:21 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-08-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-17 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-17 |
Time |
10:13 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-11-23 |
Time |
14:13 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-11-12 |
Time |
18:13 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-11-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-11-03 |
Time |
07:38 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-11-03 |
Time |
07:38 |
Sent To |
|
|
Notes |
2004-11-03 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 1 | | | | 1) NO HAND DRAWN CHANGES TO A SIGNED AND | | SEALED SET OF PLANS. SECTION 104.2.1.3 | | 2) CHANGE STATES 2" FLOOR RETURNS, BUT | | ONLY SHOWS ONE. CLARIFY WHEN | | RESUBMITTING PLANS. SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-08-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-08-23 |
Time |
10:11 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2004-08-23 |
Time |
14:15 |
Sent To |
B |
|
Notes |
2004-08-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | 1) PER SECTION 424.2.21.5 2 INLETS ARE | | REQUIRED FOR THE POOL. | | 2) VACUUM LINE CALLED OUT IN THE POOL | | SPECIFICATIONS IS NOT SHOWN ON THE POOL | | PIPING LAYOUT. CORRELATE SPECS. WITH | | POOL LAYOUT. SECTION 104.2.1 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-08-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-17 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-08-20 |
Time |
14:56 |
Sent To |
|
|
Notes |
2004-11-01 00:00:00 | TEST #2 |
|
|