Plan Review Stops For Permit 04080598 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-12-30 |
Time |
07:52 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2004-12-30 |
Time |
07:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-08-30 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-10-28 |
Time |
07:35 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
2004-08-30 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-12-23 |
Time |
05:49 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-12-23 |
Time |
05:49 |
Sent To |
P |
|
Notes |
2004-12-23 00:00:00 | REDLINEDAIC RATING ON PLANS PER | | ATTACHED LTR. | | 10K MIN. | | | | SENT TO PLUMB AND BLDG DUE TO NEW PLUMB | | SHEET AND TWO NEW BLDG SHEETS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-10-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-15 |
Time |
08:38 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-10-15 |
Time |
08:38 |
Sent To |
P |
|
Notes |
2004-10-15 00:00:00 | ******** UNSAT ********* | | | | 1)NOTE: PLEASE SEE NOTES #'1 AND 2 FROM | | PREVIOUS REVIEW. | | | | 2)NOTE: PLEASE SEE AIC RATING IS REQ- | | -UIRED AT THIS TIME. | | 110.9 | | | | 3)NOTE: PLEASE SEE AN EQUIPMENT GROUND- | | -ING CONDUCTOR IS STILL MISSING FROM | | MAIN TO PANEL. 250.24, 250.110. 250.122 | | PLEASE ALSO SEE SIZING OF CONDUIT MAY | | BE AFFECTED ONCE EQPGRND IS ADDED. | | DEPENDING ON CONDUIT TYPE. | | | | PLEASE SEE 553.80(2)(B) THIS COPY OF FS | | IS ATTACHED AND GIVEN AS A NOTICE ONLY. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | INSERT NEW SHEETS INTO COMPLETE SETS | | FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-08-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-08 |
Time |
12:17 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-08-23 |
Time |
13:19 |
Sent To |
M |
|
Notes |
2004-08-23 00:00:00 | ******** UNSAT *********** | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 | | | | 2)NOTE: PLEASE SEE MISSING EQUIPMENT | | GRND FROM MAIN TO PANEL. 250.24,250.110, | | 250.122. | | | | 3)NOTE: PLEASE SEE MISSING RECEPT FOR | | 2' OF WALL. REDLINED ON ONE SET. | | | | 4)NOTE: PLEASE SEE 220.16 FOR MIN OF 1.5 | | KW FOR LAUNDRY LOAD. SHOWN AS 1.2KW. | | | | 5 )NOTE: PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CURCUIT(S) ON PANEL | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | IN BEDROOMS ARE TO BE PROTECTED , | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | NOTE MENTIONS RECEPTS ONLY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-03-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-11 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-11 |
Time |
15:30 |
Sent To |
Z |
|
Notes |
2005-03-11 00:00:00 | TO MM DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-03-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-11 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-11 |
Time |
08:26 |
Sent To |
B |
|
Notes |
2005-03-11 00:00:00 | TO "LSMITH" DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-12-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-17 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-17 |
Time |
14:25 |
Sent To |
E |
|
Notes |
2004-12-17 00:00:00 | SENT TO "DP" DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-10-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-08 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-08 |
Time |
12:17 |
Sent To |
E |
|
Notes |
2004-10-08 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-19 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-08-13 |
Time |
12:45 |
Sent To |
|
|
Notes |
2004-08-20 00:00:00 | TO SFD RACK/E | 2004-08-13 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-10-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-10-28 |
Time |
07:35 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2004-10-28 |
Time |
07:26 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-08-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-23 |
Time |
13:23 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2004-08-25 |
Time |
06:54 |
Sent To |
P |
|
Notes |
2004-08-25 00:00:00 | DENIED: | | 1.PLAN SHEET A3 OF 4 INDICATES A 3" | | FLEX DRYER VENT.DRYER VENT SHALL BE A | | MINIMUM OF 4" & MUST HAVE A SMOOTH | | INTERIOR FINISH THEREFORE CANNOT BE FLEX | | DUCT.TERMINATION OF EXHAUST SHALL BE | | NON-SCREENED WITH A BACKDRAFT DAMPER. | | | | 2.RETURN AIR JUMPER FROM BEDROOM #2 | | SHALL BE A MINIMUM OF 10".MASTER | | BEDROOM R/A JUMPER SHALL BE A MINIMUM | | OF 14".REVISED 2001 FBC(M) 601.4 | | EXCEPTION #1 & 3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-12-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-12-29 |
Time |
18:08 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2004-12-29 |
Time |
18:08 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-12-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-12-29 |
Time |
18:09 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2004-12-29 |
Time |
18:09 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-08-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-15 |
Time |
08:38 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2004-08-28 |
Time |
10:39 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2005-03-14 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-03-14 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-03-14 |
Time |
10:38 |
Sent To |
|
|
Notes |
2005-03-14 00:00:00 | DENIED, | | 1. NEED TO APPLY FOR A SEPERATE PERMIT | | FOR WALL, WITH UTILITY DEPARTMENT | | APPROVAL FROM CITY OF W.P.B. CALLED | | CONTR FOR P/U FILE A | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-08-19 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-19 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-08-19 |
Time |
16:04 |
Sent To |
I |
|
Notes |
|
|