Plan Review Details - Permit 04080392
Plan Review Stops For Permit 04080392
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-09-12 Cont ID  
Sent By shill Date 2005-09-12 Time 18:24 Rev Time 0.00
Received By shill Date 2005-09-12 Time 18:24 Sent To PC
Notes
2005-09-12 00:00:00ENERGY CALC

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-08-15 Cont ID  
Sent By shill Date 2005-08-15 Time 14:03 Rev Time 0.50
Received By shill Date 2005-08-15 Time 14:03 Sent To  
Notes
2005-08-15 00:00:00RESTAMP - STAMPED ALL SHEETS EXCEPT 5.1
 (ELECTRIC), DID NOT MATCH MASTER

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-11-03 Cont ID  
Sent By shill Date 2004-11-03 Time 11:11 Rev Time 0.25
Received By shill Date 2004-11-03 Time 11:11 Sent To PC
Notes
2004-11-03 00:00:00REVISED ENERGY CALC

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2004-08-16 Cont ID  
Sent By csiegber Date 2004-10-28 Time 15:50 Rev Time 1.00
Received By shill Date   Time   Sent To  
Notes
2004-08-16 00:00:00SEE MASTER #04031090

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-08-16 Cont ID  
Sent By csiegber Date 2004-08-16 Time 14:02 Rev Time 2.00
Received By shill Date   Time   Sent To  
Notes
2004-08-16 00:00:00NOC, IMPACT

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-08-26 Cont ID  
Sent By dpalmer Date 2005-08-26 Time 16:54 Rev Time 0.25
Received By dpalmer Date 2005-08-26 Time 16:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2005-08-18 Cont ID  
Sent By dpalmer Date 2005-08-18 Time 18:30 Rev Time 0.00
Received By dpalmer Date 2005-08-18 Time 18:28 Sent To  
Notes
2005-08-18 00:00:00** UNSAT **
  
 PLEASE SEE SOMEITEMS REDLINED ON
 PREVIOUS PLANS NEED TO BE REVISED.
  
 1)NOTE: PLEASE SEE PANEL SCHEDULE
 INDICATES PANEL TO BE INSTALLED AS A 42
 CIRCUIT PANEL, HOWEVER RISER DIAGRAM
 NOTES MENTIONS, A 30 CIRCUIT PANEL.
 PLEASE CORRELATE.
  
 2)NOTE: PLEASE SEE SOME REDLINED AREAS
 ON PLANS WHERE RECEPT SPACING DOES NOT
 SEEM TO MEET 210.52
 LIV RM, BEDRM'S #3 AND 4.
  
 3)NOTE: PLEASE SEE AREA WHERE AHU,
 ELECTRICAL PANEL AND WATER HEATER ARE
 LOCATED, MAY NOT BE A CLOSET.
 408.7,240.24 ETC.
 PLEASE SEE THIS RM/AREA IS TO BE LABLED
 AS MECH AND/OR ELEC RM.
  
 PLEASE SUBMITTHE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-03-23 Cont ID  
Sent By dpalmer Date 2005-03-23 Time 12:23 Rev Time 0.30
Received By dpalmer Date 2005-03-23 Time 11:54 Sent To  
Notes
2005-03-23 00:00:00REDLINED 30 CIRCUIT/42 CIRCUIT PANEL.

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2005-03-03 Cont ID  
Sent By dpalmer Date 2005-03-03 Time 08:58 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2005-03-03 00:00:00NO REVIEW DONE.

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2004-08-13 Cont ID  
Sent By btrobaug Date 2004-08-13 Time 09:45 Rev Time 0.33
Received By btrobaug Date 2004-08-13 Time 07:56 Sent To B
Notes
2004-08-13 00:00:00MASTERD SET OF PLANS. SENT TO SAMANTHA
 HILL./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-09-08 Cont ID  
Sent By adarroug Date 2005-09-08 Time 18:59 Rev Time 0.00
Received By adarroug Date 2005-09-08 Time 18:59 Sent To B
Notes
2005-09-08 00:00:00TO "SHILL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-08-23 Cont ID  
Sent By adarroug Date 2005-08-23 Time 18:52 Rev Time 0.00
Received By adarroug Date 2005-08-23 Time 18:52 Sent To E
Notes
2005-08-23 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-08-17 Cont ID  
Sent By adarroug Date 2005-08-17 Time 13:40 Rev Time 0.00
Received By adarroug Date 2005-08-17 Time 13:40 Sent To E
Notes
2005-08-17 00:00:00TO "DPALMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-03-18 Cont ID  
Sent By adarroug Date 2005-03-18 Time 16:46 Rev Time 0.00
Received By adarroug Date 2005-03-18 Time 16:46 Sent To E
Notes
2005-03-18 00:00:00TO "DPALMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-02-28 Cont ID  
Sent By adarroug Date 2005-02-28 Time 08:57 Rev Time 0.00
Received By adarroug Date 2005-02-28 Time 08:57 Sent To E
Notes
2005-02-28 00:00:00TO BTROBAUG DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-10-28 Cont ID  
Sent By csiegber Date 2004-10-28 Time 15:50 Rev Time 0.00
Received By csiegber Date 2004-10-28 Time 15:50 Sent To B
Notes
2004-10-28 00:00:00TO SH DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-16 Cont ID  
Sent By csiegber Date 2004-08-16 Time 14:02 Rev Time 0.00
Received By csiegber Date 2004-08-16 Time 14:02 Sent To B
Notes
2004-08-16 00:00:00TO SH DESK/MASTER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-16 Cont ID  
Sent By mmclean Date 2004-08-12 Time 15:50 Rev Time 0.00
Received By shill Date 2004-08-10 Time 09:16 Sent To  
Notes
2004-08-12 00:00:00TO SFD RACK/E
2004-08-10 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-08-16 Cont ID  
Sent By shill Date 2004-08-16 Time 16:32 Rev Time 0.00
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-08-16 Cont ID  
Sent By shill Date 2004-08-16 Time 16:32 Rev Time 0.00
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-12 Cont ID  
Sent By mmclean Date 2004-08-12 Time 15:50 Rev Time 0.00
Received By mmclean Date 2004-08-12 Time 15:50 Sent To I
Notes
***NONE***