Plan Review Details - Permit 04080247
Plan Review Stops For Permit 04080247
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-08-16 Cont ID  
Sent By dpalmer Date 2004-10-28 Time 14:24 Rev Time 0.50
Received By lsmith Date 2004-08-16 Time 09:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-10-28 Cont ID  
Sent By dpalmer Date 2004-10-28 Time 14:24 Rev Time 0.25
Received By dpalmer Date 2004-10-28 Time 14:24 Sent To B
Notes
2004-10-28 00:00:00OK.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-10-15 Cont ID  
Sent By dpalmer Date 2004-10-15 Time 14:20 Rev Time 0.33
Received By dpalmer Date 2004-10-15 Time 14:20 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-09-20 Cont ID  
Sent By csiegber Date 2004-10-28 Time 09:52 Rev Time 0.25
Received By dpalmer Date 2004-09-20 Time 10:02 Sent To B
Notes
2004-09-20 00:00:00** UNSAT **
  
 1)NOTE: PLEASE SEE PLANS INDICATE A NEW
 PANEL ON RISER DIAGRAM. PLEASE PROVIDE
 INFORMATION FOR FEEDERS/CONDUIT/ OCP
 LOAD ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-08-11 Cont ID  
Sent By kstevens Date 2004-09-18 Time 14:16 Rev Time 0.33
Received By btrobaug Date 2004-08-11 Time 07:34 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-10-28 Cont ID  
Sent By csiegber Date 2004-10-28 Time 09:52 Rev Time 0.00
Received By csiegber Date 2004-10-28 Time 09:52 Sent To E
Notes
2004-10-28 00:00:00TO DP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-10-12 Cont ID  
Sent By csiegber Date 2004-10-12 Time 11:15 Rev Time 0.00
Received By csiegber Date 2004-10-12 Time 11:15 Sent To E
Notes
2004-10-12 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-08-24 Cont ID  
Sent By csiegber Date 2004-08-24 Time 15:39 Rev Time 0.00
Received By csiegber Date 2004-08-24 Time 15:39 Sent To P
Notes
2004-08-24 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-08-10 Time 17:21 Rev Time 0.00
Received By csiegber Date 2004-08-10 Time 17:21 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-05 Cont ID  
Sent By mmclean Date 2004-08-10 Time 16:12 Rev Time 0.00
Received By csiegber Date 2004-08-05 Time 16:46 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-10-26 Cont ID  
Sent By dpalmer Date 2004-10-28 Time 14:20 Rev Time 0.50
Received By kstevens Date 2004-10-26 Time 07:12 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-09-18 Cont ID  
Sent By kstevens Date 2004-09-18 Time 14:16 Rev Time 1.00
Received By kstevens Date 2004-09-18 Time 14:16 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-08-14 Cont ID  
Sent By csiegber Date 2004-08-24 Time 15:39 Rev Time 0.50
Received By kstevens Date 2004-08-14 Time 18:23 Sent To B
Notes
2004-08-14 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 2) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 3) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-08-05 Time 16:46 Rev Time 0.00
Received By mmclean Date 2004-08-10 Time 16:12 Sent To I
Notes
***NONE***