Plan Review Details - Permit 04080211
Plan Review Stops For Permit 04080211
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-06-13 Cont ID  
Sent By lsmith Date 2005-06-13 Time 15:30 Rev Time 0.50
Received By lsmith Date 2005-06-13 Time 15:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-05-04 Cont ID  
Sent By lsmith Date 2005-05-04 Time 09:30 Rev Time 0.50
Received By lsmith Date 2005-05-04 Time 09:30 Sent To  
Notes
2005-05-04 00:00:00BUILDING PLAN REVIEW FAILED
  
 1. SLAB MUST BE MINIMUM OF 4". DRAWING
 SHOWS 3".
  
 2. SHOW METHOD OF COMPLIANCE WITH POOL
 SAFETY ACT FOR PROTECTION OF OPENINGS
 FROM HOUSE TO POOL.
  
 3. NO RECORD OF HISTORIC APPROVAL SHOWN
 ON PLANS OR APPLICATION. TAKE PLANS TO
 5TH FLOOR FOR HISTORIC APPROVAL
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-23 Cont ID  
Sent By lsmith Date 2005-02-23 Time 08:26 Rev Time 0.50
Received By lsmith Date 2005-02-23 Time 08:26 Sent To  
Notes
2005-02-23 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. SHOW DETAIL OF ANCHORING EQUIPMENT TO
 SLAB.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH. BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2005-06-13 Cont ID  
Sent By btrobaug Date 2005-06-13 Time 11:35 Rev Time 0.25
Received By btrobaug Date 2005-06-13 Time 11:32 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-04-19 Cont ID  
Sent By btrobaug Date 2005-04-19 Time 11:38 Rev Time 0.25
Received By btrobaug Date 2005-04-19 Time 09:54 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-02-18 Cont ID  
Sent By btrobaug Date 2005-02-18 Time 13:05 Rev Time 0.33
Received By btrobaug Date 2005-02-18 Time 12:58 Sent To P
Notes
2005-02-18 00:00:00PLEASE SUBMIT DETAILS FOR THE PANEL
 SHOWN ON THE SCHEMATIC, FEEDER AND CONDU
 IT SIZE AND TYPE, PANEL RATING AND OCP,
 PANEL SCHEDULE AND COMPUTED LOAD, ETC.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-06-09 Cont ID  
Sent By shill Date 2005-06-09 Time 13:39 Rev Time 0.00
Received By shill Date 2005-06-09 Time 13:39 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-05-24 Cont ID  
Sent By adarroug Date 2005-05-24 Time 19:04 Rev Time 0.00
Received By adarroug Date 2005-05-24 Time 19:04 Sent To P
Notes
2005-05-24 00:00:00TO "KSTEVENS" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-04-14 Cont ID  
Sent By adarroug Date 2005-04-14 Time 09:40 Rev Time 0.00
Received By adarroug Date 2005-04-14 Time 09:40 Sent To E
Notes
2005-04-14 00:00:00TO "BT" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-17 Cont ID  
Sent By adarroug Date 2005-02-17 Time 12:55 Rev Time 0.00
Received By adarroug Date 2005-02-17 Time 12:55 Sent To E
Notes
2005-02-17 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-07 Cont ID  
Sent By adarroug Date 2005-02-07 Time 14:11 Rev Time 0.00
Received By adarroug Date 2005-02-07 Time 14:11 Sent To Z
Notes
2005-02-07 00:00:00TO "Z"BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-04 Cont ID  
Sent By csiegber Date 2004-08-04 Time 14:48 Rev Time 0.00
Received By csiegber Date 2004-08-04 Time 14:48 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-06-13 Cont ID  
Sent By jleech Date 2005-06-13 Time 10:54 Rev Time 0.75
Received By jleech Date 2005-06-13 Time 10:54 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-04-28 Cont ID  
Sent By kstevens Date 2005-04-28 Time 15:29 Rev Time 0.75
Received By kstevens Date 2005-04-28 Time 15:29 Sent To B
Notes
2005-04-28 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) GAS WATER HEATER TIE DOWN DETAIL
 SHOWS THE CONCRETE PAD AS 3", WHEREAS
 THE TYPICAL SLAB DETAIL ON THE GENERAL
 NOTES SHEET SHOW A 4" THICK SLAB AS IS
 REQUIRED. PLEASE CORRELATE DETAILS.
 SECTION 104.2.1.
 2) SPECIFICATION SHEET SHOWS THE SHEER
 DECENT/LION HEAD RETURNS ON THE SIDE OF
 THE POOL, BUT THE LAYOUT SHEET SHOWS
 THESE RETURNS AT THE END OF THE POOL.
 PLEASE CLARIFY AND CORRELATE SHEETS.
 SECTION 104.2.1.
 3) TWO SETS OF PLANS ARE REQUIRED TO BE
 SUBMITTED WITH APPLICATION FOR PERMIT.
 LOOSE SHEETS ARE NOT SETS OF PLANS.
 SECTION 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-02-22 Cont ID  
Sent By kstevens Date 2005-02-22 Time 18:48 Rev Time 0.50
Received By kstevens Date 2005-02-22 Time 18:48 Sent To B1
Notes
2005-02-22 00:00:00DENIED
 REFERENCE: FBC-424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
  
 1) THE FOLLOWING INFORMATION IS REQUIRED
 ON THE PLANS EITHER IN THE FORM OF
 NOTES, DRAWINGS, OR SUBMITTALS:
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK. - NO
 VACUUM LINE IS SHOWN ON THE POOL LAYOUT
 SHEET, BUT A VACUUM LINE IS INDICATED ON
 THE PIPING SCHEMATIC. PLEASE CLAIRFY AND
 CORRELATE PIPING SCHEMATIC WITH POOL
 LAYOUT. (GIVE DETAIL, SUBMITTAL OR ADD
 TO NOTES) SECTION 104.2.1.
 3) FBC-2001424.2.6.6.4 MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR EA
 PUMP. SEPARATED BY A MINIMUM OF 3 FEET
 OR LOCATED ON TWO DIFFERENT PLANES.
 (DETAIL)- UNABLE TO READ MINIMUM
 SEPARATION BETWEEN MAIN DRAINS ON THE
 PLANS. PLEASE INDICATE 3 FT. SECTION
 104.2.1.
 4) SHEET WITH PIPING SCHEMATIC HAS A
 NOTE THAT STATES "HEATER IS EXCEMPT FROM
 STATE ENERGY CODE AS HEAT SOURCE IS AND,
 IS 90% EFICIENT". THIS IS NOT THE CASE
 WITH GAS POOL HEATERS AND SHALL BE
 DELETED FROM THE PLANS.
 5) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 6) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUF. CUT SHEETS - SUBMITTAL)
 7) FBC-2001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED. (ADD TO NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2005-02-16 Cont ID  
Sent By mmclean Date 2005-02-16 Time 15:30 Rev Time 0.00
Received By mmclean Date 2005-02-16 Time 15:30 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-08-04 Time 14:48 Rev Time 0.00
Received By mmclean Date 2004-08-10 Time 11:42 Sent To  
Notes
2004-08-10 00:00:00DENIED, MUST BE 10FT ON THE SIDE.
 CALLED CONTR FILE UNDER B FOR P/U MM