Plan Review Details - Permit 04080209
Plan Review Stops For Permit 04080209
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-11-08 Cont ID  
Sent By lsmith Date 2004-11-08 Time 09:15 Rev Time 0.50
Received By lsmith Date 2004-11-08 Time 09:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-08-12 Cont ID  
Sent By kstevens Date 2004-09-23 Time 15:04 Rev Time 0.00
Received By lsmith Date 2004-08-12 Time 12:10 Sent To  
Notes
2004-08-12 00:00:00BUILDING PLAN REVIEWA; FAILED
  
 1. SHOW METHOD OF COMPLIANCE WITH POOL S
 SAFETY ACT ON PLANS.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-12-01 Cont ID  
Sent By btrobaug Date 2004-12-01 Time 13:15 Rev Time 0.33
Received By btrobaug Date 2004-12-01 Time 13:07 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-11-05 Cont ID  
Sent By btrobaug Date 2004-11-05 Time 14:23 Rev Time 0.00
Received By btrobaug Date 2004-11-05 Time 14:15 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-08-06 Cont ID  
Sent By csiegber Date 2004-08-06 Time 16:45 Rev Time 0.33
Received By btrobaug Date 2004-08-06 Time 17:22 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-11-19 Cont ID  
Sent By csiegber Date 2004-11-19 Time 11:19 Rev Time 0.00
Received By csiegber Date 2004-11-19 Time 11:19 Sent To P
Notes
2004-11-19 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-10-06 Cont ID  
Sent By csiegber Date 2004-10-06 Time 14:27 Rev Time 0.00
Received By csiegber Date 2004-10-06 Time 14:27 Sent To P
Notes
2004-10-06 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-09-01 Cont ID  
Sent By csiegber Date 2004-09-01 Time 13:14 Rev Time 0.00
Received By csiegber Date 2004-09-01 Time 13:14 Sent To P
Notes
2004-09-01 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-06 Cont ID  
Sent By csiegber Date 2004-08-06 Time 16:45 Rev Time 0.00
Received By csiegber Date 2004-08-06 Time 16:45 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-04 Cont ID  
Sent By mmclean Date 2004-08-06 Time 16:33 Rev Time 0.00
Received By csiegber Date 2004-08-04 Time 14:48 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-12-01 Cont ID  
Sent By kstevens Date 2004-12-01 Time 07:01 Rev Time 0.50
Received By kstevens Date 2004-11-30 Time 18:53 Sent To E
Notes
2004-12-01 00:00:00 
 FBC-2001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
  
  
  
  
  
  
  
  
 .

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-11-02 Cont ID  
Sent By kstevens Date 2004-11-02 Time 12:18 Rev Time 1.25
Received By kstevens Date 2004-11-02 Time 11:31 Sent To E
Notes
2004-11-02 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING
 POOLS
 FBC-2001 CHAPTER 1
  
 FROM PREVIOUS REVIEW:
 4) FBC-2001 424.2.14.1 SWIMMING POOL
 HEATERS SHALL BEAR THE LABEL OF A REC-
 OGNIZED TESTING AGENCY. MANUF. SHEETS
 REQUIRED. (SUBMITTAL)
 5) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. MANUF CUT SHEETS (SUBMITTAL)
 6) FBC-2001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE
 PLANS AND PERMIT REQUIRED.
 8) POOL PIPING LAYOUT SHOWS MAIN DRAIN
 LINE CONNECTING TO ONE MAIN DRAIN,
 WHERE
 AS PIPING SCHEMATIC INDICATES
 CONNECTION
 AT THE CENTER OF THE MAIN DRAINS. (ALSO
 SEE APPROVED SWIMMING POOL & SPA DUAL
 MAIN DRAIN ATMOSPHERIC VENT ARRANGEMENT
 DETAIL). PER SECTION 424.2.6.6.4 THESE
 SUCTION INLETS SHALL BE PLUMBED SUCH
 THAT WATER IS DRAWN THROUGH THEM SIM-
 ULTANEOUSLY. CORRECT THE PIPING LAYOUT
 TO REFLECT THE EQUIPMENT SCHEMATIC AND
 DRAIN/VENT ARRANGEMENT COMPLIANT WITH
 SECTION 424.2.6.6.
 A) PLEASE ADJUST YOUR NOTES, DETAILS,
 OR SUBMITTALS TO REFLECT THE ABOVE
 INFORMATION REQUIRED FOR PLAN REVIEW.
 ***NEW COMMENT
 1B) POOL PIPING SCHEMATIC HAS HAND
 DRAWN CHANGES. THIS IS NOT APPROVED.
 SUBMIT NEW PIPING SCHEMATIC WITH ALL
 APPROVED CHANGES.
 2B) REMOVE ALL VOIDED SHEETS, SUBMIT
 2 SETS OF PLANS FOR REVIEW AND ONE SET
 OF VOIDED SHEETS FOR COMPAIRSON.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-09-23 Cont ID  
Sent By csiegber Date 2004-10-06 Time 14:27 Rev Time 0.33
Received By kstevens Date 2004-09-23 Time 15:04 Sent To B
Notes
2004-09-23 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) AS REQUIRED BY 104.3.1.1 OF THE CODE,
 TWO OR MORE COPIES OF DRAWINGS ARE RE-
 QUIRED. - COMPLETE SETS WERE NOT SUBMIT-
 TED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-08-11 Cont ID  
Sent By csiegber Date 2004-09-01 Time 13:14 Rev Time 1.25
Received By kstevens Date 2004-08-11 Time 16:19 Sent To B
Notes
2004-08-11 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 3) FBC-2001424.2.6.6.3 (1,2,3) ENTRAP-
 MENT AVOIDANCE. (DETAIL)
 4) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 5) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 6) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
 7) POOL EQUIP SCHEDULE & PIPING SCHEMAT-
 IC INDICATE A VACUUM CLEANER LINE, BUT
 POOL PIPING LAYOUT DOES NOT REFLECT THIS
 ITEM. PLEASE CORRELATE PLANS. SECTION
 104.2.1.
 8) POOL PIPING LAYOUT SHOWS MAIN DRAIN
 LINE CONNECTING TO ONE MAIN DRAIN, WHERE
 AS PIPING SCHEMATIC INDICATES CONNECTION
 AT THE CENTER OF THE MAIN DRAINS. PER
 SECTION 424.2.6.6.4 THESE SUCTION INLETS
 SHALL BE PLUMBED SUCH THAT WATER IS
 DRAWN THROUGH THEM SIMULTANEOUSLY. CORR-
 ECT THE PIPING LAYOUT TO REFLECT THE
 EQUIPMENT SCHEMATIC. SECTION 1104.2.1.
 9) EQUIPMENT PIPING SCHEMATIC CALLS OUT
 THE POOL HEATER AS A 109K HEAT PUMP, BUT
 EQUIPMENT SPECIFICATIONS INDICATE A 400K
 NATURAL GAS POOL HEATER. CORRELATE PLANS
 SECTION 104.2.1.
 10) PIPING SCHEMATIC NOTES STATE: HEATER
 IS EXEMPT FROM STATE ENERGY CODE AS A
 HEAT SOURCE IS 90% EFFECIENT. GAS HEAT-
 ERS ARE NOT EXEMPT. DELETE NOTE. SECTION
 104.2.1.
 11) ANTI ENTRAPMENT PIPING DESIGN NOTES
 #3. ENTRAPMENT DEVICES SHALL, (NOT MAY),
 COMPLY WITH ANSI/ASME A112.19.8.M. SECT-
 ION 424.2.6.6.2.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-06 Cont ID  
Sent By csiegber Date 2004-08-04 Time 14:48 Rev Time 0.00
Received By mmclean Date 2004-08-06 Time 16:33 Sent To I
Notes
***NONE***