Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-08-20 Cont ID  
Sent By alange Date 2004-08-20 Time 08:48 Rev Time 1.00
Received By alange Date 2004-08-20 Time 08:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-08-19 Cont ID  
Sent By alange Date 2004-08-19 Time 11:06 Rev Time 0.66
Received By alange Date 2004-08-19 Time 11:06 Sent To  
Notes
2004-08-19 00:00:00DENIED
 4. FROM LAST REVIEW
 SUBMIT PRODUCT APPROVALS FOR USP
 CONNECTORS,ONLY DCA APPROVALS
 SUBMITTED
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-08-17 Time 12:46 Rev Time 2.50
Received By alange Date 2004-08-10 Time 10:37 Sent To M
Notes
2004-08-10 00:00:00DENIED
  
 1.THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2. ATTIC ACCESS SHALL COMPLY WITH
 FBC2309.6.SHOW ON PLANS.
  
 3.BASED ON SBCCI BUILDING VALUATION
 DATA, THE BUILDING VALUATION HAS BEEN
 CHANGED TO $242,263.
 2229 SQ FT X $76.96 = $171,543
 1700 SQ FT X $41.6 =$70,720
 ADDITIONAL PERMIT FEES OF $435.52 ARE
 DUE BEFORE ISSSUING OF PERMIT.
  
 4.SUBMIT PRODUCT APPROVALS FOR USP
 CONNECTORS.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 ART LANGE
 BUILDING PLAN REVIEW
 TEL: (561)805-6672
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-04-27 Cont ID  
Sent By dpalmer Date 2005-04-27 Time 14:08 Rev Time 0.30
Received By dpalmer Date 2005-04-27 Time 14:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-04-21 Cont ID  
Sent By dpalmer Date 2005-04-21 Time 13:37 Rev Time 0.50
Received By dpalmer Date 2005-04-21 Time 13:37 Sent To  
Notes
2005-04-21 00:00:00********UNSAT *********
  
 1)NOTE:PLEASE SHOW METER/MAIN ON PLAN
 WHICH IS LOCATED OUTSIDE WHERE OLD METER
 IS SHOWN?
 215.5
  
 2)NOTE: PLEASE SEE NOW THAT A METER/MAIN
 IS INSTALLED, AN EQUIPMENT GROUNDING
 CONDUCTOR IS REQUIRED TO BE INSTALLED
 FROM METER/MAIN TO PANEL "B".
 250.110,250.24, 250.122
  
 3)NOTE: PLEASE SHOW METER MAIN WITH FEED
 THRU LUGS, OR LIST OCP ON METER MAIN
 PANEL SCHEDULE "A".
  
 4)NOTE: PLEASE VERIFY PANEL "B" IS STILL
 SHOWN AS MCB, EVEN NOW THAT A MAIN IS
 INSTALLED OUTSIDE. PLEASE SEE THIS IS
 PERMITTED, HOWEVER NOT REQUIRED.
 THIS IS ONLY A NOTE: IF SHOWN AS MCB,
 THEN A MCB WILL BE REQUIRED PER PLANS.
  
 5)NOTE: PLEASE IDENTIFY NEW RECEPTS
 ADDED TO REAR PORCH AND GARAGE AS GFI.
 210.8
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-08-09 Cont ID  
Sent By btrobaug Date 2004-08-09 Time 12:46 Rev Time 0.50
Received By btrobaug Date 2004-08-09 Time 07:57 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-04-26 Cont ID  
Sent By adarroug Date 2005-04-26 Time 09:30 Rev Time 0.00
Received By adarroug Date 2005-04-26 Time 09:30 Sent To E
Notes
2005-04-26 00:00:00TO "DPALMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-04-19 Cont ID  
Sent By adarroug Date 2005-04-19 Time 14:41 Rev Time 0.00
Received By adarroug Date 2005-04-19 Time 14:41 Sent To E
Notes
2005-04-19 00:00:00TO "DPALMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-17 Cont ID  
Sent By csiegber Date 2004-08-17 Time 12:46 Rev Time 0.00
Received By csiegber Date 2004-08-17 Time 12:46 Sent To B
Notes
2004-08-17 00:00:00TO AL DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-11 Cont ID  
Sent By mmclean Date 2004-08-05 Time 15:10 Rev Time 0.00
Received By pkrauss Date 2004-08-04 Time 14:26 Sent To  
Notes
2004-08-06 00:00:00TO SFD RACK/E
2004-08-04 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-08-11 Cont ID  
Sent By jleech Date 2004-08-10 Time 17:42 Rev Time 0.30
Received By pkrauss Date 2004-08-11 Time 06:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-08-10 Cont ID  
Sent By jleech Date 2004-08-10 Time 17:42 Rev Time 0.25
Received By jleech Date 2004-08-10 Time 17:42 Sent To M
Notes
2004-08-10 00:00:00NO RISER DIAGRAM.

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-05 Cont ID  
Sent By mmclean Date 2004-08-05 Time 15:10 Rev Time 0.00
Received By mmclean Date 2004-08-05 Time 15:10 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy