Plan Review Stops For Permit 04080034 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-11-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-11-01 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2004-11-01 |
Time |
16:05 |
Sent To |
|
|
Notes |
2004-11-01 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04080034 | | ADD: 4017 PINEWOOD AVE STREET | | SCAPE | | CONT: WEST CONSTRUCTION | | TEL: (561)718-8656 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | 2ND REVIEW | | ACTION: DENIED | | | | SEE NOTES FROM FIRST REVIEW, NO CHANGE! | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-08-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-08-24 |
Time |
11:21 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2004-08-24 |
Time |
11:21 |
Sent To |
|
|
Notes |
2004-08-24 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04080034 | | ADD: 4017 PINEWOOD AV | | CONT: WEST CONSTRUCTION | | TEL: (561)718-8656 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1ST REVIEW | | ACTION: DENIED | | | | SHEET S-1 THE ENGINEERING FIRM MUST CON- | | TAIN THE CERTIFICATE OF AUTHORIZATION, | | 61G15-23.002 (2). | | | | S-1 MISSING INFORMATION REQUIRED: | | FL. BLD CODE 1606.1.7 THE FOLLOWING | | INFORMATION RELATED TO WIND SHALL BE | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | 1)- BASIC WIND SPEED, MPH | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | CATEGORY | | 3)- WIND EXPOSURE | | 4)- INTERNAL PRESSURE COEFFICIENT, | | 5)- COMPONENTS & CLADDING, THE DESIGN | | WIND PRESSURES IN TERMS OF PSF. | | | | FL BLD CODE 1606.1.5: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORTS,MISSING REPORTS ARE AS | | FOLLOWS: | | A) ROOFING ASSEMBLIES | | B) TRUSS ANCHORS | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-10-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-25 |
Time |
16:58 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-10-25 |
Time |
16:51 |
Sent To |
|
|
Notes |
2004-10-25 00:00:00 | ********* UNSAT 2ND REVIEW ******* | | | | 1)NOTE: PLEASE SEE NOTES FROM PREVIOUS | | REVIEW. | | RESPONSE LETTER MENTIONS TO SEE REVISED | | PLANS DATED 10/5/04, YET PLANS THAT | | WERE SUBMITTED ARE DATED 8/2/04. | | THIS ARE THE SAME PLANS REVIEWED ON | | PREVIOUS SUBMITTAL. | | | | *** PLEASE SEE ORIGIANL COMMENTS.*** | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-08-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-17 |
Time |
16:25 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2004-08-17 |
Time |
16:21 |
Sent To |
|
|
Notes |
2004-08-17 00:00:00 | ************* UNSAT ************** | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 | | PLEASE INCLUDE PRINTED NAME AND LICENSE | | # OF PE ON TITLE BLOCK. | | | | **THIS IS ALSO REQUIRED ON ALL SHEETS | | AND FOR ALL TRADES/ARCH/STRUCAL/LANSCAPE | | PLANS. ** | | PLEASE 61G1-16.004 FOR ARCH/FIRM REQ'MNT | | | | 2)NOTE: PLEASE ADJUST PLANS FOR WHAT | | NOW SHOWS A REMOVAL OF ONE OF THE GAZEBO | | 'S. | | | | 3)NOTE: PLEASE SEE 225.31 FOR DISC MEANS | | AT DETACHED BLDGS. | | | | 4)NOTE: PLEASE SEE RISER SHOWS A GRND | | ROD BEING ADDED BEFORE METER?? | | PLEASE SEE 250.6,250.24,250.50 | | GRND RDS TO BE AT LOCATION OF SERVICE. | | | | PLEASE SEE SPLICING OF SEC'S AND NOTE ON | | PLANS FOR SPECIFIC REQUIREMENTS. | | | | 5)NOTE: PLEASE ALSO PROVIDE WIND LOAD | | ON PLANS. WIND LOAD CALCS WERE SUBMITTED | | AND WILL STILL BE REVIEWED BY BLDG PLAN | | REVIEW. PLANS DO NOT SEEM TO CORRELATE | | FOR STRUCTUAL DETAIL. | | | | 6)NOTE: PLEASE PROVIDE INFORMATION ON | | MEANS OF DISCONNECT FOR SERVICE EQUIP- | | -MENT. 230.76,230.79, 110.27. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2004-08-18 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2004-08-18 |
Time |
10:06 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2004-08-18 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-20 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-20 |
Time |
12:35 |
Sent To |
|
|
Notes |
2004-10-20 00:00:00 | TO COMM BD#63 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-08-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-20 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-03 |
Time |
12:01 |
Sent To |
|
|
Notes |
2004-08-03 00:00:00 | TO COMM BD#34 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-08-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-08-05 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-08-05 |
Time |
10:13 |
Sent To |
|
|
Notes |
|
|