Plan Review Stops For Permit 04071290 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-08-06 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-08-06 |
Time |
11:24 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
2004-08-06 |
Time |
11:24 |
Sent To |
|
|
Notes |
2004-08-06 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | 1. A NOTICE OF COMMENCEMENT MUST BE | | FILED AT THE COUNTY CLERK OFFICE AND A | | COPY SUBMITTED BEFORE A PERMIT CAN BE | | ISSUED. | | | | 2. SUBMIT MANUFACTURERS SHEETS ON THE | | GAS BBQ TO BE INSTALLED. | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-07 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-07 |
Time |
14:32 |
Sent To |
|
|
Notes |
2005-12-07 00:00:00 | REDLINED NFPA 72 | | 11.8.3.5 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2005-10-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-21 |
Time |
15:06 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-10-21 |
Time |
14:22 |
Sent To |
|
|
Notes |
2005-10-21 00:00:00 | ******** UNSAT ********* | | | | 1)NOTE: PLEASE SEE LOAD ON PANEL "C" | | EXCEEDS FEEDER AND OCP FOR PANEL. | | PLEASE ALSO INDICATE ALL CONTINUOUS | | LOADS AT 125%. | | 215.3,230.42 ETC. | | PLEASE REVISE 240.4,310.16,310.15B6 | | | | 2)NOTE: PLEASE SEE BOTH PANELS "A" AND | | "B" INDICATE BEING MLO. | | PLEASE SEE RISER SHOWS THESE AS MCB. | | PLEASE CORRELATE AND INDICATE MCB'S AS | | REQIRED 230.70 | | | | 3)NOTE: PLEASE SEE GROUNDING ELECTRODE | | IS NOW SHOWN GOING TO SLAB, HOWEVER THIS | | SHOULD BE NOTED AS FOOTER STEEL. 250.50 | | | | 4)NOTE: PLEASE CORRELATE RECESSED LTS ON | | LOAD CALCULATIONS AND THE NUMBER OF LTS | | SHOWN ON PLANS. | | 215.5,220.3 | | | | | | ** NOTE ALL SD'S ARE TO BE INSTALLED | | WITH IN THE HIGHEST POINT OF A FLAT | | CEILING. | | PLEASE BE SURE TO VERIFY INSTALLATION IN | | FIELD. | | NFPA-72 8-1 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-05-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-05-16 |
Time |
06:57 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-05-16 |
Time |
06:57 |
Sent To |
|
|
Notes |
2005-05-16 00:00:00 | | | REV OK. | | TRIED TO LEAVE MESSAGE AT 6:58AM ON 5/16 | | NO ANSWERING MACHINE/OR VOICE MAIL. | | PLANS UNDER "T" FOR PU. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-04-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-04-20 |
Time |
07:22 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-04-20 |
Time |
07:22 |
Sent To |
|
|
Notes |
2005-04-20 00:00:00 | ******* UNSAT ******* | | | | 1)NOTE: PLEASE SEE PANEL "C" IS MISSING | | FROM PLANS. PLEASE SHOW LOCATION OF | | PANEL "C" ON PLANS. | | 215.5 | | | | 2)NOTE: PLEASE SEE RECEPT FOR WHIRLPOOL | | TUB NOT SHOWN AS GFI/GFI PROTECTED. | | 680.24 | | | | 3)NOTE: PLEASE SEE MISSING GFI ON | | POWDER/BATHRM. 210.52D, 210.8 | | | | 4)NOTE: PLEASE SEE NOTE #2 ON GEN NOTES | | MENTIONS SD'S ON KIT/BATH LIGHTING | | CIRCUITS, HOWEVER THESE ARE REQUIRED TO | | HAVE ARC FAULT PROTECTION PER 210.12 | | 2002 NEC. | | IF ON KIT/BATH LIGHTING CIRCUIT(S), | | THESE WOULD ALSO BE REQUIRED TO BE AFCI. | | | | PLEASE KNOW, SINCE PLANS ARE IN FOR | | FINAL, ALL ITEMS MUST BE CORRECT. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-07-31 |
Time |
08:48 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-08-03 |
Time |
09:01 |
Sent To |
M |
|
Notes |
2004-08-03 00:00:00 | ******** REDLINED ************ | | | | 1)NOTE: PLEASE SEE AHU#3 AND MEANS OF | | DISC AND OCP SHOWN ON CLOTHES CLOSET. | | THIS IS NOT PERMITTED. | | PLEASE SEE 240.24D AND 110.26 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-11-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-28 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-28 |
Time |
15:50 |
Sent To |
E |
|
Notes |
2005-11-28 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-10-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-12 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-12 |
Time |
13:05 |
Sent To |
E |
|
Notes |
2005-10-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-05-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-10 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-10 |
Time |
12:15 |
Sent To |
E |
|
Notes |
2005-05-10 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-04-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-14 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-14 |
Time |
17:46 |
Sent To |
E |
|
Notes |
2005-04-14 00:00:00 | TO "DPALMER"DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-02-01 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-02-01 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-02-01 |
Time |
14:30 |
Sent To |
M |
|
Notes |
2005-02-01 00:00:00 | TO "M/AC"/REVISIONS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-08-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-07-29 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-07-28 |
Time |
14:36 |
Sent To |
|
|
Notes |
2004-07-29 00:00:00 | TO SFD RACK/E | 2004-07-28 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2005-02-09 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-02-09 |
Time |
11:31 |
Rev Time |
1.50 |
Received By |
prafter |
Date |
2005-02-09 |
Time |
11:31 |
Sent To |
|
|
Notes |
2005-02-09 00:00:00 | PROVISO: | | PROVIDE FOR COMBUSTION AIR FOR DRYER | | IF REQUIRED. | | GAS DRYED INFORMATION ,NOT WITH PLAN | | PACKAGE. | | PAT RAFTER 2/9/05 651/805/6728. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2004-08-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-03 |
Time |
09:01 |
Rev Time |
0.50 |
Received By |
rregueir |
Date |
2004-08-07 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-07-31 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-07-31 |
Time |
08:48 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2004-07-31 |
Time |
08:48 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-07-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-07-29 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-07-29 |
Time |
16:07 |
Sent To |
I |
|