Plan Review Details - Permit 04071250
Plan Review Stops For Permit 04071250
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-09-21 Cont ID  
Sent By lsmith Date 2004-09-21 Time 16:18 Rev Time 0.75
Received By lsmith Date 2004-09-21 Time 16:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-08-11 Cont ID  
Sent By btrobaug Date 2004-09-20 Time 15:34 Rev Time 0.50
Received By lsmith Date 2004-08-11 Time 15:39 Sent To  
Notes
2004-08-11 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. SHOW AREA OF PAVER DECK. LIST SQ FT
 ON PLAN.
 2. SHOW METHOD OF PROTECTING THE
 OPENINGS OF THE HOUSE TO THE POOL ON
 PLANS.
 3. VALUE OF POOL TOO LOW. NEED SQ FT OF
 DECK TO COST OUT POOL & DECK.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-09-20 Cont ID  
Sent By btrobaug Date 2004-09-20 Time 15:32 Rev Time 0.33
Received By btrobaug Date 2004-09-20 Time 15:29 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-08-03 Cont ID  
Sent By kstevens Date 2004-09-20 Time 14:01 Rev Time 0.33
Received By btrobaug Date 2004-08-03 Time 18:15 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-08-24 Cont ID  
Sent By csiegber Date 2004-08-24 Time 16:02 Rev Time 0.00
Received By csiegber Date 2004-08-24 Time 16:02 Sent To P
Notes
2004-08-24 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 16:47 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 16:47 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-28 Cont ID  
Sent By mmclean Date 2004-07-29 Time 16:00 Rev Time 0.00
Received By csiegber Date 2004-07-28 Time 11:44 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-09-20 Cont ID  
Sent By kstevens Date 2004-09-20 Time 14:01 Rev Time 0.50
Received By kstevens Date 2004-09-20 Time 14:00 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-08-11 Cont ID  
Sent By csiegber Date 2004-08-24 Time 16:02 Rev Time 0.50
Received By kstevens Date 2004-08-11 Time 13:25 Sent To B
Notes
2004-08-11 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS. (ADD TO NOTES)
 2) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 3) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 4) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 5) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
 6)ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-28 Time 11:44 Rev Time 0.00
Received By mmclean Date 2004-07-29 Time 15:59 Sent To I
Notes
2004-07-29 00:00:00ZBA #3087 - GRACE JOYCE PLANNER 822-1447


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved