Plan Review Stops For Permit 04071132 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-09-21 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-09-20 |
Time |
14:27 |
Rev Time |
1.00 |
Received By |
lsmith |
Date |
2004-09-20 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-08-06 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-09-20 |
Time |
08:06 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
2004-08-06 |
Time |
09:21 |
Sent To |
|
|
Notes |
2004-08-06 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | 1.PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, | | 2003ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | WWW.FLORIDABUILDING.ORG | | 1. GLASS BLOCK 1 HR. FIRE RATED | | | | 2. APPLICATION SHOWS OWNER AS KENCO; | | OUR SYSTEM HAS MSK PARTNERS AS OWNER. | | SUBMIT CORRECT OWNER INFORMATION, | | WARRANTY DEED, ETC. | | | | 3. A NOTICE OF COMMENCEMENT MUST BE | | FILED AT THE COUNTY CLERKS OFFICE AND A | | COPY SUBMITTED BEFORE A PERMIT CAN BE | | ISSUED. | | | | 4. THE VALUE OF THE STRUCTURE HAS BEEN | | INCREASED PER MARSHALL & SWIFT. | | ADDITIONAL FEES OF $189.09 ARE DUE | | BEFORE A PERMIT CAN BE ISSUED. | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-07-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-07-21 |
Time |
12:23 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-07-21 |
Time |
11:15 |
Sent To |
|
|
Notes |
2005-07-21 00:00:00 | REDLINED: | | | | SD'S SHOWN ON CIRCUIT 24 ON PLANS, | | HOWEVER PANEL SCHEDULE SHOWS GARAGE LTS | | FOR THIS CIRCUIT??REDLINED |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-09-16 |
Time |
18:53 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-09-16 |
Time |
18:53 |
Sent To |
P |
|
Notes |
2004-09-16 00:00:00 | REDLINED NOTE: | | | | GEC TO FOOTER STEEL. 250.50 SHOWS SLAB. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-08-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-09-15 |
Time |
14:37 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-08-02 |
Time |
15:03 |
Sent To |
M |
|
Notes |
2004-08-02 00:00:00 | ********** UNSAT ************** | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 | | | | 2)NOTE: PLEASE SEE SERVICE IS BEING | | SHOWN AS 225A'S YET SEC'S ARE ONLY | | RATED FOR 200A'S. | | | | 3 )NOTE: PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CURCUIT(S) ON PANEL | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | IN BEDROOMS ARE TO BE PROTECTED , | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | 2002 NEC 210.12B | | NOT ONLY RECEPTS. SD'S SHOWN ON BATH LT | | CIRCUIT? | | | | 4)NOTE: PLEASE SEE MISSING FOOTER STEEL | | AND CWP AS PART OF GROUNDING ELECTRODE | | SYSTEM. 250.50 | | | | 5)NOTE: PLEASE SEE FOYER WILL REQUIRE | | A LT FIX OF SOME SORT FOR MEANS OF | | EGRESS. 210.70/LS101.5-8 | | | | 6)NOTE: PLEASE SEE SD IN MASTER HALL TO | | BE MOVED INTO BEDRM. | | NFPA-72 8-1.4.1.6.2 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-07-20 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-07-20 |
Time |
14:04 |
Sent To |
E |
|
Notes |
2005-07-20 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-02-01 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-02-01 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-02-01 |
Time |
14:18 |
Sent To |
M |
|
Notes |
2005-02-01 00:00:00 | TO "M/AC" BOX REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-09-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-09-15 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-09-15 |
Time |
14:36 |
Sent To |
E |
|
Notes |
2004-09-15 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-08-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-07-29 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-07-28 |
Time |
11:58 |
Sent To |
|
|
Notes |
2004-07-29 00:00:00 | TO SFD RACK/E | 2004-07-28 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2005-02-09 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-02-09 |
Time |
12:03 |
Rev Time |
1.50 |
Received By |
prafter |
Date |
2005-02-09 |
Time |
12:02 |
Sent To |
|
|
Notes |
2005-02-09 00:00:00 | PROVISO: | | 1. RETURN AIR OUT OF MASTER BEDROOM | | AREA REQUIRES 18" JUMPER. 2003 FBC/M | | 601.4 EXCEPTION #1. | | 2. AUX. DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED. 2001 FBC/M 307.2.3 | | . | | 3. PROVIDE FOR CONBUSTION AIR FOR DRYER | | IF REQUIRED. | | GAS DRYER INFORMATION NOT WITH PLAN | | PACKAGE. | | | | PAT RAFTER 2/9/05 561/805/6728. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-09-20 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-09-20 |
Time |
08:06 |
Rev Time |
0.00 |
Received By |
prafter |
Date |
2005-02-09 |
Time |
11:59 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-08-07 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-09-18 |
Time |
10:56 |
Rev Time |
0.50 |
Received By |
rregueir |
Date |
2004-08-07 |
Time |
09:24 |
Sent To |
|
|
Notes |
2004-08-07 00:00:00 | ----------------DENIED------------------ | | NO PLANS OR MANUAL-J SUBMITTED WITH | | THIS PERMIT APPLICATION | | | | ANY QUESTIONS PLEASE CALL: | | RONALD J REGUEIRO | | 561-805-6734 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-09-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-09-18 |
Time |
10:56 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2004-09-18 |
Time |
10:56 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-07-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-09-16 |
Time |
18:54 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2004-07-31 |
Time |
07:30 |
Sent To |
E |
|
Notes |
2004-07-31 00:00:00 | RISER DIAGRAM NOT TO CODE AND CANNOT BE | | INSTALLED AS DRAWN. ASK PLUMBING | | CONTRACTO FOR HELP. | | PLUMBING PLAN REVIEW BY | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-07-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-07-29 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-07-29 |
Time |
10:05 |
Sent To |
I |
|
Notes |
|
|