Plan Review Details - Permit 04071132
Plan Review Stops For Permit 04071132
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-09-21 Cont ID  
Sent By lsmith Date 2004-09-20 Time 14:27 Rev Time 1.00
Received By lsmith Date 2004-09-20 Time 14:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-08-06 Cont ID  
Sent By pkrauss Date 2004-09-20 Time 08:06 Rev Time 2.00
Received By lsmith Date 2004-08-06 Time 09:21 Sent To  
Notes
2004-08-06 00:00:00BUILDING PLAN REVIEW FAILED:
  
 1.PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 WWW.FLORIDABUILDING.ORG
 1. GLASS BLOCK 1 HR. FIRE RATED
  
 2. APPLICATION SHOWS OWNER AS KENCO;
 OUR SYSTEM HAS MSK PARTNERS AS OWNER.
 SUBMIT CORRECT OWNER INFORMATION,
 WARRANTY DEED, ETC.
  
 3. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT THE COUNTY CLERKS OFFICE AND A
 COPY SUBMITTED BEFORE A PERMIT CAN BE
 ISSUED.
  
 4. THE VALUE OF THE STRUCTURE HAS BEEN
 INCREASED PER MARSHALL & SWIFT.
 ADDITIONAL FEES OF $189.09 ARE DUE
 BEFORE A PERMIT CAN BE ISSUED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-07-21 Cont ID  
Sent By dpalmer Date 2005-07-21 Time 12:23 Rev Time 0.33
Received By dpalmer Date 2005-07-21 Time 11:15 Sent To  
Notes
2005-07-21 00:00:00REDLINED:
  
 SD'S SHOWN ON CIRCUIT 24 ON PLANS,
 HOWEVER PANEL SCHEDULE SHOWS GARAGE LTS
 FOR THIS CIRCUIT??REDLINED

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-09-16 Cont ID  
Sent By dpalmer Date 2004-09-16 Time 18:53 Rev Time 0.25
Received By dpalmer Date 2004-09-16 Time 18:53 Sent To P
Notes
2004-09-16 00:00:00REDLINED NOTE:
  
 GEC TO FOOTER STEEL. 250.50 SHOWS SLAB.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-08-02 Cont ID  
Sent By csiegber Date 2004-09-15 Time 14:37 Rev Time 0.50
Received By dpalmer Date 2004-08-02 Time 15:03 Sent To M
Notes
2004-08-02 00:00:00********** UNSAT **************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 2)NOTE: PLEASE SEE SERVICE IS BEING
 SHOWN AS 225A'S YET SEC'S ARE ONLY
 RATED FOR 200A'S.
  
 3 )NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
 2002 NEC 210.12B
 NOT ONLY RECEPTS. SD'S SHOWN ON BATH LT
 CIRCUIT?
  
 4)NOTE: PLEASE SEE MISSING FOOTER STEEL
 AND CWP AS PART OF GROUNDING ELECTRODE
 SYSTEM. 250.50
  
 5)NOTE: PLEASE SEE FOYER WILL REQUIRE
 A LT FIX OF SOME SORT FOR MEANS OF
 EGRESS. 210.70/LS101.5-8
  
 6)NOTE: PLEASE SEE SD IN MASTER HALL TO
 BE MOVED INTO BEDRM.
 NFPA-72 8-1.4.1.6.2
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-20 Cont ID  
Sent By adarroug Date 2005-07-20 Time 14:04 Rev Time 0.00
Received By adarroug Date 2005-07-20 Time 14:04 Sent To E
Notes
2005-07-20 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-01 Cont ID  
Sent By mjacobs Date 2005-02-01 Time 14:19 Rev Time 0.00
Received By mjacobs Date 2005-02-01 Time 14:18 Sent To M
Notes
2005-02-01 00:00:00TO "M/AC" BOX REVISION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-09-15 Cont ID  
Sent By csiegber Date 2004-09-15 Time 14:36 Rev Time 0.00
Received By csiegber Date 2004-09-15 Time 14:36 Sent To E
Notes
2004-09-15 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-06 Cont ID  
Sent By mmclean Date 2004-07-29 Time 10:05 Rev Time 0.00
Received By lsmith Date 2004-07-28 Time 11:58 Sent To  
Notes
2004-07-29 00:00:00TO SFD RACK/E
2004-07-28 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-02-09 Cont ID  
Sent By prafter Date 2005-02-09 Time 12:03 Rev Time 1.50
Received By prafter Date 2005-02-09 Time 12:02 Sent To  
Notes
2005-02-09 00:00:00PROVISO:
 1. RETURN AIR OUT OF MASTER BEDROOM
 AREA REQUIRES 18" JUMPER. 2003 FBC/M
 601.4 EXCEPTION #1.
 2. AUX. DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED. 2001 FBC/M 307.2.3
 .
 3. PROVIDE FOR CONBUSTION AIR FOR DRYER
 IF REQUIRED.
 GAS DRYER INFORMATION NOT WITH PLAN
 PACKAGE.
  
 PAT RAFTER 2/9/05 561/805/6728.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-09-20 Cont ID  
Sent By pkrauss Date 2004-09-20 Time 08:06 Rev Time 0.00
Received By prafter Date 2005-02-09 Time 11:59 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-08-07 Cont ID  
Sent By jleech Date 2004-09-18 Time 10:56 Rev Time 0.50
Received By rregueir Date 2004-08-07 Time 09:24 Sent To  
Notes
2004-08-07 00:00:00----------------DENIED------------------
 NO PLANS OR MANUAL-J SUBMITTED WITH
 THIS PERMIT APPLICATION
  
 ANY QUESTIONS PLEASE CALL:
 RONALD J REGUEIRO
 561-805-6734

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-09-18 Cont ID  
Sent By jleech Date 2004-09-18 Time 10:56 Rev Time 0.50
Received By jleech Date 2004-09-18 Time 10:56 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-31 Cont ID  
Sent By dpalmer Date 2004-09-16 Time 18:54 Rev Time 0.50
Received By jleech Date 2004-07-31 Time 07:30 Sent To E
Notes
2004-07-31 00:00:00RISER DIAGRAM NOT TO CODE AND CANNOT BE
 INSTALLED AS DRAWN. ASK PLUMBING
 CONTRACTO FOR HELP.
 PLUMBING PLAN REVIEW BY
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2004-07-29 Cont ID  
Sent By mmclean Date 2004-07-29 Time 10:05 Rev Time 0.00
Received By mmclean Date 2004-07-29 Time 10:05 Sent To I
Notes
***NONE***