Plan Review Stops For Permit 04071011 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2004-11-12 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
2004-11-12 00:00:00 | REVISION OK LM |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-11-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-11-04 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2004-11-04 |
Time |
07:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-09-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-09-20 |
Time |
09:56 |
Rev Time |
1.55 |
Received By |
jwitmer |
Date |
2004-09-20 |
Time |
08:46 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-08-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-08-03 |
Time |
14:14 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2004-08-03 |
Time |
14:13 |
Sent To |
|
|
Notes |
2004-08-03 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04071011 | | ADD: 315 S OLIVE AV SUITE 104 | | CONT: RAPP CONSTRUCTION | | TEL: (561)248-6411 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) MISSING ELECTRICL PAGE? THERE IS NO | | ELECTRIC SHOWN FOR THE CORRESPONDING | | A3.1 PAGE. NO EXIT SIGNS CAN BE IDENTI- | | FIED ON THE CORRIDORS, 140, UNNUMBERED | | CORRIDOR LINKING WITH 140 TO 131, 128 | | AND 132. | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 3) UNISEX RESTROOM SHEET 8.2 GRAB BAR | | BEHIND THE WATERCLOSET, THE DIMENSION IS | | 3'-0" BUT THE PLAN IS DRAWN SHORTER? | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-11-10 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2004-11-10 |
Time |
15:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-10-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-27 |
Time |
06:08 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-10-27 |
Time |
06:05 |
Sent To |
|
|
Notes |
2004-10-27 00:00:00 | REV ON E-1,E-2 OK. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-08-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-30 |
Time |
15:23 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-08-30 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-07-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-07-27 |
Time |
14:02 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-07-27 |
Time |
14:02 |
Sent To |
|
|
Notes |
2004-07-27 00:00:00 | ********** NOTES REDLINED ************ | | | | 1)NOTE: PLEASE SEE 210.63 FOR MISSING | | ROOFTOP GFI RECEPT. | | | | 2)NOTE: PLEASE CORRELATE ALL OCP, AWG | | AND LOADS FOR AHU'S/ A/C SYSTEMS. | | PLEASE SEE 424.3B FOR SIZING OF OCP. | | | | THE ABOVE HAS BEEN REDLINED AND THERE IS | | NO NEED FOR CORRECTION AT THIS TIME. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | ELETCRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-11-23 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-11-23 |
Time |
10:04 |
Sent To |
|
|
Notes |
2004-11-23 00:00:00 | REVISION BLDG/ELEC/MECH DATED 10-12-04 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-11-10 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-11-10 |
Time |
17:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-09-16 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-09-16 |
Time |
12:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-07-30 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-07-30 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-07-30 |
Time |
10:01 |
Sent To |
|
|
Notes |
2004-07-30 00:00:00 | 1) IT WOULD APPEAR THAT ADDITIONAL | | EXIT SIGNS ARE NEEDED IN CORRIDOR 128 | | AND 132. | | | | 2) ARE THERE ANY EXISTING EMERGENCY | | LIGHTS IN RESTROOMS. | | | | 3) PLEASE EXPLAIN ABANDONED EXISTING | | STAIRS NOTE. | | | | 4) ANY FIRE ALARM EQUIPMENT PRESENT. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-25 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-25 |
Time |
11:49 |
Sent To |
|
|
Notes |
2004-10-25 00:00:00 | TO COMM BD#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-20 |
Time |
16:52 |
Sent To |
|
|
Notes |
2004-10-20 00:00:00 | TO COMM BD# |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-08-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-19 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-19 |
Time |
14:24 |
Sent To |
|
|
Notes |
2004-08-19 00:00:00 | TO COMM BD#32 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-07-23 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-07-23 |
Time |
12:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-11-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-11-05 |
Time |
14:16 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2004-11-05 |
Time |
13:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-09-17 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-09-17 |
Time |
14:26 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2004-09-17 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-08-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-08-05 |
Time |
15:50 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2004-08-05 |
Time |
15:18 |
Sent To |
|
|
Notes |
2004-08-05 00:00:00 | DENIED: | | PLEASE PROVIDE ADDITIONAL INFORMATION | | ON A/C SYSTEM #1 & 3.PROVIDE | | MANUFACTURER CONFIRMATION THAT AHU 1 & | | 3 DOES NOT HAVE THE CAPACITY TO OUTPUT | | GREATER THAN 2,000 CFM. | | | | PLAN SHEET M1, DUCT & GRILLE SIZE | | MISSING ON 1 BRANCH LINE FROM SYSTEM | | 2 AND ONE BRANCH LINE FROM SYSTEM 1. | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-11-17 |
Time |
15:19 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-11-17 |
Time |
15:19 |
Sent To |
|
|
Notes |
2004-11-17 00:00:00 | NO PLUMBING REVISION SHOWN |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-09-16 |
Time |
18:53 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-09-16 |
Time |
18:52 |
Sent To |
|
|
Notes |
2004-09-16 00:00:00 | PASSED/PROVISO | | | | | | SINK SHALL COMPLY WITH 11-4.24 AND ALL | | SUBSECTIONS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-07-31 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2004-07-31 |
Time |
11:12 |
Rev Time |
2.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2004-07-31 00:00:00 | PLUMBING PLAN REVIEW FBC 2001 FL ADA | | SEC 11-4.24 SINK CLEARANCE, HGTH 34" FF | | CLEAR FLOOR SPACE 30" X 48". |
|
|