Plan Review Stops For Permit 04070845 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-10-20 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-10-20 |
Time |
11:54 |
Rev Time |
0.25 |
Received By |
mjacobs |
Date |
2004-10-20 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-08-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-10-15 |
Time |
19:47 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2004-08-04 |
Time |
10:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-10-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-10-18 |
Time |
09:21 |
Rev Time |
0.25 |
Received By |
btrobaug |
Date |
2004-10-18 |
Time |
09:07 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-07-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-10-15 |
Time |
19:47 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2004-07-22 |
Time |
14:18 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-05 |
Time |
15:08 |
Sent To |
P |
|
Notes |
2004-10-05 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-08-12 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-12 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-12 |
Time |
16:28 |
Sent To |
P |
|
Notes |
2004-08-12 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-22 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-22 |
Time |
09:42 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-07-21 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-07-21 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-21 |
Time |
08:55 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2004-10-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-10-18 |
Time |
09:21 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-10-15 |
Time |
19:47 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2004-09-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:09 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-08-23 |
Time |
16:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-08-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-08-21 |
Time |
12:36 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2004-08-21 |
Time |
12:36 |
Sent To |
B |
|
Notes |
2004-08-21 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 1 | | FBC-2001 424.2 SWIMMING POOLS | | | | 1) ALL CHANGES TO A SIGNED/SEALED/DATED | | SET OF PLANS SHALL BE SIGNED AND DATED | | BY THE ENGINEER OF RECORD. (SEE GLUED ON | | REVISION AND HAND DRAWN HARTFORD LOOP). | | | | **FROM PREVIOUS REVIEW: | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 6) FBC02001 424.2.15 GAS PIPING SHALL | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | AND PERMIT REQUIRED. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-08-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-12 |
Time |
16:29 |
Rev Time |
0.60 |
Received By |
kstevens |
Date |
2004-08-03 |
Time |
07:19 |
Sent To |
B |
|
Notes |
2004-08-03 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE | | WITH ANSI/ASME A112.19.8M. PROVIDE MODEL | | NUMBER AND MANUF INFO FOR VAC LOCK. | | (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) | | 2) FBC-2001424.2.6.6.5 WHERE PROVIDED, | | THE VACUUM OR PRESSURE CLEANER FITTING | | SHALL BE LOCATED AT LEAST 6" AND NOT | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | THE SKIMMER. | | 3) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | ORD. #2853-95, BACKFLOW REQUIRED ON | | WATER SERVICE. (ADD TO NOTES) | | 4) FBC-2001 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES) | | 5) FBC-2001 424.2.13.2JOINTS AND CON- | | NECTIONS, FBC PLMG SEC 605.21, PURPLE | | PRIMER REQUIRED ON PVC PIPING. (ADD TO | | NOTES) | | 6) FBC02001 424.2.15 GAS PIPING SHALL | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | AND PERMIT REQUIRED. | | 7) EXTERNAL HARTFORD LOOP REQUIRED. NO | | INTERNAL MEANS OF WATER RETENTION IS | | SHOWN. SECTION 424.2.14.2 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-07-21 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-21 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-07-21 |
Time |
15:39 |
Sent To |
I |
|