Plan Review Details - Permit 04061166
Plan Review Stops For Permit 04061166
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-12-08 Cont ID  
Sent By rmcdouga Date 2004-12-08 Time 07:15 Rev Time 0.00
Received By rmcdouga Date 2004-12-08 Time 07:02 Sent To  
Notes
2004-12-08 00:00:00IMPACT FEES PAID AND UNITY OF TITLE
 RECORDED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-10-12 Cont ID  
Sent By rmcdouga Date 2004-10-12 Time 14:07 Rev Time 0.00
Received By rmcdouga Date 2004-10-12 Time 14:07 Sent To  
Notes
2004-10-12 00:00:00BUILDING PROVISO
  
 1) SUBMIT PRODUCT APPROVAL FOR IMPACT
 RATED EXTERIOR DOORS.
  
 2) RECORDED COPY OF UNITY OF TITLE IS
 TO BE SUBMITTED BEFORE PERMIT IS ISSUED.
  
 3) IMPACT FEES TO BE PAID TO COUNTY AND
 PLANS STAMPED BY THEM BEFORE PERMIT IS
 ISSUED. SUBMIT COPY OF PAID RECEIPT AND
 PLANS WITH COUNTY STAMP.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-13 Cont ID  
Sent By csiegber Date 2004-09-20 Time 13:54 Rev Time 2.50
Received By rmcdouga Date 2004-07-13 Time 14:35 Sent To  
Notes
2004-07-13 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) SUBMIT PROOF OF UNITY OF TITLE FOR
 THE TWO LOTS.
  
 3) CLARIFY NOTE (D) ON A1. THE FASTENERS
 ARE REQUIRED TO HAVE 1-3/4" PENETRATION
 INTO THE FRAMING MEMBERS PER ASTM 1063.
  
 4) FBC 1012.1 REQUIRES AT LEAST ONE
 EXTERIOR EGRESS DOOR WITH A 32" CLEAR
 OPENING.
  
 5) THE POSITIVE AND NEGATIVE WINDLOAD
 PRESSURES LISTED ON THE PLANS FOR SOME
 OF THE OPENINGS ARE INCORRECT. SEE
 FBC 1606.2.3 AND 1606.2.5.
  
 6)THE WALL SECTION ON SHEET A2 SPECIFIES
 R-30 INSULATION AND THE ENERGY CALC.
 FORM LISTS R-19. PLEASE CORRECT.
  
 7) SPECIFY TERMITE TREATED SOIL ON A3.
 SEE FBC 1816.
  
 8) THE UPLIFT VALUE FOR THE (2) HETAL 20
 CONNECTORS IN THE SCHEDULE ON A3 IS TOO
 MUCH. SEE 2004 SIMPSON CATALOG FOR
 VALUES THAT DO NOT INCLUDE A ONE-THIRD
 INCREASE ON THE STEEL CALCS. THE MAX.
 UPLIFT IS 1810# FOR A HETAL 20.
  
 9)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 10) THE WRONG FL# IS LISTED ON THE
 LAWSON SINGLE HUNG WINDOWS. SEE THE
 ATTACHED FL COVER SHEET.
  
 11) THE NOA FOR THE DOUBLE OUTSWING DOOR
 IS NOT APPLICABLE. THERE ARE NO DOUBLE
 DOORS SHOWN ON THE PLAN.
  
 12) SUBMIT STATE PRODUCT APPROVALS FOR
 THE EXTERIOR DOORS (FRONT, DINING ROOM
 AND STORAGE).
  
 13) SUBMIT A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS. SPECIFY
 SHUTTER TYPE (ALUMINUM OR STEEL), MOUNT
 TYPE, FASTENER TYPE, FASTENER SPACING.
 CIRCLE OR HIGHLIGHT THE APPROPRIATE
 ITEMS ON THE PRODUCT APPROVAL.
  
 IF YOU HAVE QUESTIONS CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-07-01 Cont ID  
Sent By jleahy Date 2004-07-01 Time 08:01 Rev Time 1.00
Received By jleahy Date 2004-07-01 Time 08:01 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-06 Cont ID  
Sent By mjacobs Date 2004-12-06 Time 15:56 Rev Time 0.00
Received By mjacobs Date 2004-12-06 Time 15:56 Sent To B
Notes
2004-12-06 00:00:00SENT TO "ROB MCD" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-09-20 Cont ID  
Sent By csiegber Date 2004-09-20 Time 13:54 Rev Time 0.00
Received By csiegber Date 2004-09-20 Time 13:54 Sent To B
Notes
2004-09-20 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-13 Cont ID  
Sent By mmclean Date 2004-06-25 Time 15:52 Rev Time 0.00
Received By rmcdouga Date 2004-06-24 Time 14:54 Sent To  
Notes
2004-06-28 00:00:00TO SFD RACK/E
2004-06-24 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-07-07 Cont ID  
Sent By jleech Date 2004-07-01 Time 17:18 Rev Time 0.35
Received By pkrauss Date 2004-07-07 Time 12:35 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-07-01 Cont ID  
Sent By jleahy Date 2004-07-01 Time 08:01 Rev Time 0.25
Received By jleech Date 2004-07-01 Time 17:17 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-06-25 Cont ID  
Sent By mmclean Date 2004-06-25 Time 15:52 Rev Time 0.00
Received By mmclean Date 2004-06-25 Time 15:52 Sent To I
Notes
***NONE***